Produttore : Delfield
File Size : 1.4 mb
File Nome : 735509b8-a693-c304-199c-fb952e6ce16d.pdf
|
Facilità d'uso
Refrigerated Work Tables, Salad Tables & Freezer Bases Effective Date December 2007 IMPORTANTINFORMATION READBEFOREUSE PLEASESAVETHESEINSTRUCTIONS! F18 Series Service and Installation Manual Contents Serial Number Location SERIAL NUMBER LOCATION................................................2 RECEIVING & INSPECTING ..................................................2 SPECIFICATIONS .............................................................. 3-5 INSTALLATION......................................................................6 OPERATION ..........................................................................6 CARE AND CLEANING ..........................................................7 PRESSURE CONTROL SETTINGS.........................................7 CONDENSING UNIT ASSEMBLY ....................................... 8-9 MULLION COIL ASSEMBLY (REFRIGERATED) ...................10 MULLION COIL ASSEMBLY (FREEZER)..............................11 DRAWER ASSEMBLY: LOW PROFILE REFR, 2 & 3 HIGH...12 CARTRIDGE STYLE DRAWER SYSTEMS............................13 DOOR ASSEMBLY: LOW PROFILE......................................14 DOOR ASSEMBLY: MARK 7................................................15 LOUVERED DOOR ASSEMBLY. ...........................................15 REPLACEMENT PARTS LISTS ...................................... 16-19 WIRING DIAGRAMS ...........................................................20 TROUBLESHOOTING REFERENCE CHART..........................21 WARRANTIES ............................................................... 22-23 AUTHORIZED PARTS DEPOTS............................(back cover) The serial number on all self-contained F18 Series refrigerated work tables and freezer bases is located on the electrical specifications tag affixed inside the compressor section next to the pressure control. On remote refrigerated bases with doors, the tag is inside the unit on the coil side. On remote refrigerated bases with drawers, the tag is affixed to the drawer divider. On remote freezer bases, the tag is located on the inside back of the unit. Always have the serial number of your unit available when calling for parts or service. A complete list of authorized Delfield parts depots is shown on the back cover of this manual. ©2007 The Delfield Company. All rights reserved. Reproduction withoutwritten permission is prohibited. “Delfield” is a registered trademark of The Delfield Company. Receiving and Inspecting the Equipment Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building. 1. Visually inspect the exterior of the package an skid or container. Any damage should be noted and reported to the delivering carrier immediately. 2. If damaged, open and inspect the contents with the carrier. 3. In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form. 4. Request an inspection of the concealed equipment. This should be done within 10 days from receipt of the equipment. 5. Check the lower portion of the unit to be sure legs or casters are not bent. 6. Also open the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact. 7. Freight carriers can supply the necessary forms upon request. 8. Retain all crating material until an inspection has been made or waived. Uncrating the Equipment First cut and remove the banding from around the crate. Remove the front of the crate material, use of some tools will be required. If the unit is on legs remove the top of the crate as well and lift the unit off the skid. If the unit is on casters it can be "rolled" off the skid. ™ ® Delfield For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, F18 Series Service and Installation Manual Specifications MODEL # OF STORAGE SHELF AREA RECOMMENDED VOLTS/HERTZ/ BTU EVAP. CAP. NUMBER DOORS CU. FT. SQ. FT. HORSE POWER PHASE AMPS LOAD BTU/°TD Remote Refrigerated Work Tables F18WR31 (1) 19” 6.99 2.56 1/5 115/60/1 3.0 383 120 F18WR39 (1) 27” 9.77 3.95 1/5 115/60/1 3.0 465 120 F18WR44 (2) 19” 11.52 5.12 1/5 115/60/1 3.0 605 120 F18WR52 (1) 19” & (1) 27” 14.31 6.51 1/5 115/60/1 3.0 686 120 F18WR60 (2) 27” 18.85 7.90 1/4 115/60/1 3.0 768 120 F18WR70 (2) 32” 20.59 9.64 1/4 115/60/1 3.0 869 120 F18WR79 (2) 27” & (1) 19” 23.05 10.29 1/4 115/60/1 6.0 1050 240 F18WR87 (3) 27” 25.83 11.85 1/4 115/60/1 6.0 1131 240 MODEL # OF STORAGE SHELF AREA VOLTS/HERTZ/ BTU BTU NUMBER DOORS CU. FT. SQ. FT. HORSE POWER PHASE AMPS LOAD SYSTEM Self-Contained Refrigerated Work Tables F18WC39 (1) 19” 6.99 2.56 1/5 115/60/1 8.0 383 1462 F18WC47 (1) 27” 9.77 3.95 1/5 115/60/1 8.0 465 1462 F18WC52 (2) 19” 11.52 5.12 1/5 115/60/1 8.0 605 1462 F18WC60 (1) 19” & (1) 27” 14.31 6.51 1/5 115/60/1 8.0 686 1462 F18WC68 (2) 27” 18.85 ...