Log:
valutazioni - 3, GPA: 3 ( )

Istruzioni per l'uso Delfield, Modello ZIFP360NX

Produttore : Delfield
File Size : 190.73 kb
File Nome : 2d857ca3-5940-4524-b384-839abc38280b.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


to 84-1/2" max. height. Note: the top case trim at the front is 1/2" higher and will overlap upper cabinetry or soffit. Use leveling legs and wheels for a maximum 1" height adjustment. Product Clearances These units are equipped with a 2-position door stop. The factory set 130. door swing can be adjusted to 90. if clearance to adjacent cabinets or walls is restricted. Order WX14X99 door stop for precise settings between 90.and 130.. 25" Minimum to Wall 130.Door Swing 90.Door Swing 23-7/8" Behind Frame 36-3/4" 5" Min. to Wall Allow 25" minimum clearance for a full 130. door swing. Allow 15" for pan removal. for a 90. door swing, allow 5" minimum clearance for professional models. If the 90. doorstop position is used, pan access is maintained but pan removal is restricted. For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. ZIFP360NXRH, Freezer Handle on the left side, the door swings left to right. ZIFP360NXLH, Freezer Handle on the right side, the door swings right to left. Caution These units are top-heavy and must be secured to prevent the possibility of tipping forward. Anti-Tip protection is required. The water and electrical supply must be located as shown. The finished cutout width must be 35-1/2". Note: The case trim overlaps cabinets at the top and sides. Frameless cabinets may require filler strips to prevent interference with cabinet door swing. The opening width must allow for filler strips. Listed by Underwriters Laboratories Specification Created 6/08 110151 ZIFP360NX GE Monogram® 36" Built-In Professional All-Freezer Dimensions and Installation Information Cutout and Clearances for Multiple Product Installations If you are installing two units, side by side, the installation space must be 71-1/2" wide. Additional cutout width may be required when side panels are used. Add side panel thickness to the finished cutout to calculate rough-in width. • The water and electrical locations for each product must be located as shown. • A separate 115V, 60Hz., 15 or 20 amp power supply is recommended for each product. 25" Min. to Wall 0" 25" Min. to Wall130.Door Swing 130.Door Swing Clearances for two products installed side-by-side with right and left side hinges together Clearances for Multiple Single Door Installations In a side-by-side installation of a left and right door swing product, the inside trims touch at the front, with a 1" clearance between the units at the rear. Order ZUGPP2 Professional Unified Grille Panel Kit for one continuous grille panel. ZUGPP2: For side-by-side installation of two professional models. This kit provides a unified stainless steel grille panel to span the width of two units. For a complete food storage center, install a Monogram All-Refrigerator and All Freezer side-by-side. For even more capacity, install two refrigerators or two freezers. 5" For answers to your Monogram,® GE Profile™ or GE® appliance questions, ...

Questo manuale è adatto anche per i modelli :
congelatori - ZIFP360NX (190.73 kb)
congelatori - ZIFP360NX (190.73 kb)
congelatori - ZIFP360NX (190.73 kb)
congelatori - ZIFP360NX (190.73 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie