Log:
valutazioni - 4, GPA: 4.3 ( )

Istruzioni per l'uso Arcam, Modello AM/FM Tuner T61

Produttore : Arcam
File Size : 905.04 kb
File Nome : da6d26f4-45f2-4fab-b156-aa59232630d0.pdf
Lingua di insegnamento: enfrde
Vai a scaricare



Facilità d'uso


If the RDS button is pressed while tuned to a non-RDS station, the display shows ‘NO NAME’ for three seconds before reverting to the default display. Entering station names manually Station names can be entered and saved for preset AM stations, and for FM stations where RDS is not available. Station names can be up to eight characters long. First select the band and the preset station you wish to name. Then press and hold the RDS button for more than two seconds. An ‘underscore’ line should appear blinking in the first position of the frequency display area. Use the 5 and 6 buttons beneath the display to scroll through the available alphabet, numbers and special characters available until you reach your wanted letter or character. Press the TUNING button to confirm that character. The ‘underscore’ line will then move to the next position. Repeat this process to enter the required name. If you want to edit a character later, use the TUNING button to step along and select it, then use the 5 and 6 keys as before to change it. When complete, press STORE to enter the name into the preset memory. Using the CR-389 remote control FM/DAB Ensure that the FM mode is selected using the FM/DAB toggle button. The FM LED above the FM/DAB button is lit briefly when FM is selected. MENU (RDS mode) This button scrolls through RDS modes, when available. DISP (Display) This button allows you to dim or switch off the tuner display. FMDABPROGDISPRPTMODEBAND1–92–103–11FMDABSELTUNERCR-389CDAMPLIFIERVCRDVDTAPEAVTUNERCDAUXPHONOENTERSP1SP2DISPMENUDISP4–125–136–147–158–16 STANDBY This button switches the tuner (and the amplifier if appropriate) between ‘On’ and ‘Standby’. Preset memory buttons These buttons allow access to individual preset stations. To select a preset press the corresponding keypad button. For presets 9–16, press and hold the corresponding preset button for one second. Use the Tune buttons to access FM memory presets 17 to 30. Tune buttons These buttons enable you to scroll through the stored station selections one at a time, or to tune up or down, depending on the Tuning mode. BAND This button toggles between FM and AM. MODE (Tuning mode) This button toggles between PRESET and TUNE modes. Amplifier controls These buttons offer basic control over Arcam amplifiers, such as the A65, A75 or A85. CD player controls These buttons offer basic control over Arcam CD players, such as the CD62, CD72, CD82 or CD92. NOTE: DAB (Digital Audio Broadcast) refers to Arcam DAB tuners such as model DT81. NOTE: Remember to install the two AAA batteries supplied before trying to use your remote control. Do not place anything in front of the display area on the tuner (where the IR receiver is located), or the remote control may not work. Technical specifications T61 Tuner FM Section Tuning range 87.5 to 108.0MHz Frequency steps 50kHz Presets: total/direct access 30/16 Sensitivity (IHF) for 50dB S/N ratio typically 3.V Alternate channel selectivity better than 60dB Capture ratio 1.5dB Frequency response 20Hz–15kHz ±1dB Ultimate S/N ratio (CCIR) Mono better than –75dB Stereo better than –70dB Total harmonic distortion (96MHz reference, 22.5kHz deviation at 1kHz) Mono better than 0.1% Stereo better than 0.2% Channel separation (1kHz) better than 40dB Pilot tone suppression better than 60dB Output level 700mV at 75kHz deviation AM Section Tuning range: 10kHz step 530 to 1710 kHz 9kHz step 531 to 1602 kHz Presets 16 Usable sensitivity typically 30.V IF rejection > 36dB S/N ratio (30% mod., 50mV I/P) > 38dB Total harmonic distortion (30% mod., 50mV I/P) < 3% Output level 300mV at 70% modulation Control inputs IR remote standard Philips RC-5, 36kHz carrier IR in signal level 4–15V pk-pk Trigger operating voltage 9–15V DC Trigger in polarity tip positive General Output impedance 220. Minimum recommended load 5k. Power consumption 10VA Size W x D x H 430 x 290 x 85mm Weight net 3.8kg Weight packed 6.0kg Supplied accessories FM dipole aerial AM loop aerial mains lead CR-389 remote control handset and batteries E&OE NOTE: All specification values are typical unless otherwise stated. Continual improvement policy Arcam has a policy of continual improvement for its products. This means that designs and specifications are subject to change without notice. Table of IR commands Command Decimal code Standby 17–124 On 17–123 Power toggle 17–12 AM/FM band toggle 17–50 AM band 17–52, 17–46 FM band 17–53, 17–45 Tune down (seek if >1second) 17–31 Tune up (seek if >1second) 17–30 Seek tune down 17–35 Seek tune up 17–34 RDS program 17–62 RDS text 17–63 RDS frequency 17–64 Scroll RDS mode 17–55, 17–61, 17–15 Display on 17–14 Display toggle 17–18 Stereo 17–39 Mono 17–54 Stereo/Mono toggle 17–38 Preset/tune mode toggle 17–37 Preset/tune up 17–32 Preset/tune down 17–33 Store 17–41 Mute on 17–119 Mute off 17–120 Mute toggle 17–13 Preset 1 to 8 (9 to 16 if >1second) 17–1 to 17–8 Preset 9 17–9 Preset 10 to 17 17–110 to 17–117 Preset 18 to 30 17–88 to 17–100 NOTE: The ab...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie