Log:
valutazioni - 4, GPA: 4.3 ( )

Istruzioni per l'uso Roland, Modello SP-606 V2

Produttore : Roland
File Size : 1.65 mb
File Nome :
Lingua di insegnamento: ende
Vai a scaricare



Facilità d'uso


.All Sounds Off (Controller number 120) Status 2nd byte 3rd byte BnH 78H 00H n = MIDI channel number: 0H - FH (ch.1 - ch.16) * If the All Sound Off message is received, all notes will be silenced regardless of their channel. .All Notes Off (Controller number 123) Status 2nd byte 3rd byte BnH 7BH 00H n = MIDI channel number: 0H - FH (ch.1 - ch.16) *When All Notes Off is received, all samples whose Trig Mode is GATE and that are in a note-on state will be silenced, regardless of their channel. MIDI Implementation ¦System Common Message .Song Position Pointer Status 2nd byte 3rd byte F2H mmH llH (mm ll: 00 00H - 7F 7FH (0 - 16383)) * This message is received if Sync Mode is SLAVE. ¦System Realtime Message .Timing Clock Status F8H * This message is received if Sync Mode is SLAVE. .Start Status FAH * This message is received if Sync Mode is SLAVE or REMOTE. .Continue Status FBH * This message is received if Sync Mode is SLAVE or REMOTE. .Stop Status FCH * This message is received if Sync Mode is SLAVE or REMOTE. .Active Sensing Status FEH ¦System Exclusive Message Status Data byte Status F0H iiH, ddH, ......, eeH F7H F0H: System Exclusive Message status ii = ID number: an ID number (manufacturer ID) to indicate the manufacturer whose Exclusive message this is. Roland’s manufacturer ID is 41H. ID numbers 7EH and 7FH are extensions of the MIDI standard; Universal Non-realtime Messages (7EH) and Universal Realtime Messages (7FH). dd,..., ee = data: 00H - 7FH (0 - 127) F7H: EOX (End Of Exclusive) .Universal Non-realtime System Exclusive Messages .Identity Request Status F0H Data byte 7EH, dev, 06H, 01H Status F7H Byte F0H Explanation Exclusive status 7EH ID number (universal non-realtime message) dev Device ID (00H - 1FH (1 - 32)) 06H, 01H Identity Request F7H EOX (End Of Exclusive) * Even if the Device ID is 7FH (Broadcast), Identity reply message will be transmitted. .Data set 1 (DT1) Status Data byte Status F0H 41H, dev, 00H, 6EH, 12H,F7H aaH, bbH, ccH, ddH, eeH,... ffH, sum Byte Explanation F0H Exclusive status 41H ID number (Roland) dev Device ID (00H - 1FH (1 - 32)) 00H 6EH Model ID (SP-606) 12H Command ID (DT1) aaH Address MSB: bbH Address ccH Address ddH Address LSB eeH Data: the actual data to be transmitted. Multiple bytes of data are transmitted starting from the address. : : ffH Data sum Checksum F7H EOX (End Of Exclusive) 2. Transmit data * For details on the messages that are transmitted during V-LINK operation, refer to “Chapter 10. About V-LINK” (p. 75). ¦Channel Voice Messages * Channel voice messages are transmitted in NOTE TRIG mode. * For the correspondence between note numbers and pad banks, refer to “MIDI on the SP-606” (p. 78). .Note Off Status 2nd byte 3rd byte 8nH kkH 40H n = MIDI channel number: 0H - 7H (ch.1 - ch.8) kk = note number: 23H - 62H (35 - 98) .Note On Status 2nd byte 3rd byte 9nH kkH vvH n = MIDI channel number: 0H - 7H (ch.1 - ch.8) kk = note number: 23H - 62H (35 - 98) vv = note on velocity: 01H - 7FH (1 - 127) ¦System Common Message .Song Position Pointer Status 2nd byte 3rd byte F2H mmH llH (mm ll: 00 00H - 7F 7FH (0 - 16383)) * This message is transmitted only if Tx MIDI Sync is ON. MIDI Implementation ¦System Realtime Message .Timing Clock Status F8H * This message is transmitted only if Tx MIDI Sync is ON. .Start Status FAH * This message is transmitted only if Tx MIDI Sync is ON or during EXT SEQ SAMPLING. .Continue Status FBH * This message is transmitted only if Tx MIDI Sync is ON or during EXT SEQ SAMPLING. .Stop Status FCH * This message is transmitted only if Tx MIDI Sync is ON or during EXT SEQ SAMPLING. .Active Sensing Status FEH ¦System Exclusive Message .Universal Non-realtime System Exclusive Messages .Identity Reply Status Data byte Status F0H 7EH, 10H, 06H, 02H, 41H,F7H 6EH, 01H, 00H, 00H, 00H, 02H, 00H, 00H Byte Explanation F0H Exclusive status 7EH ID number (universal non-realtime message) 10H Device ID 06H 02H Identity Reply 41H ID number (Roland) 6EH 01H Device family code 00H 00H Device family number code 00H 02H 00H 00H software revision level F7H EOX (End Of Exclusive) .Data set 1 (DT1) Status Data byte Status F0H 41H, 10H, 00H, 6EH, 12H,F7H aaH, bbH, ccH, ddH, eeH,... ffH, sum Byte Explanation F0H Exclusive status 41H ID number (Roland) 10H Device ID 00H 6EH Model ID (SP-606) 12H Command ID (DT1) aaH Address MSB bbH Address ccH Address ddH Address LSB eeH Data: the actual data to be sent. Multiple bytes of data are transmitted in order starting from the address. : : ffH Data sum Checksum F7H EOX (End Of Exclusive) 3. Parameter address map ¦Addresses Transmitted and Received When Switching to EXT Mode The following address is transmitted and received when switching to EXT mode. Address Description Data (Value) 00 00 00 00 EXT Control mode 0 (OFF), 1 (ON/PART SELECT), 2 (ON/MUTE), 3 (ON/SOLE), 4 (ON/SEQ TRIGGER), 5 (ON/NOTE TRIGGER) MIDI Implementation ¦Addresses Transmitted by Panel Operations ¦Other Addresses Received The following addresses are trans...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie