Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso Roland, Modello UM-3EX

Produttore : Roland
File Size : 6.25 mb
File Nome :
Lingua di insegnamento: itenesfrde
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


111 Conexion e instalacion de los controladores (Macintosh).......................................... 114 Antes de instalar el controlador .............................................................................................. 114 Instalacion del controlador y ajustes ...................................................................................... 115 Usuarios de Mac OS X .................................................................................................................................. 115 Apendices ........................................................................................................................ 120 Conexion de varias unidades UM-3EX .................................................................................. 120 Index ................................................................................................................................. 122 9 Contents of the Package The UM-3EX includes the following items. When you open the package, first make sure that all items are included. If any are missing, contact the dealer where you purchased the UM-3EX. USB MIDI Interface UM-3EX fig.um-3-front.eps_50 CD-ROM This contains drivers for use with the UM-3EX. Owner’s Manual This is the manual you are reading. Please keep it on hand for reference. 10 Names of Things and What They Do fig.front.eps_25 MIDI IN Connectors Connect these to the MIDI OUT connectors of the devices (such as a MIDI keyboard) that will be transmitting MIDI messages to your computer. MIDI OUT/THRU Connectors Connect these to the MIDI IN connectors of sound modules or other devices to which you’ll be sending MIDI messages from your computer for playback. MIDI IN Indicators If the THRU switch is OFF, this lights when MIDI messages from the device connected to MIDI IN are being received. MIDI OUT Indicators If the THRU switch is OFF, this lights when MIDI messages from the computer are being transmitted. THRU Switches Allow you to select the output destinations of the MIDI messages that arrive from the devices you’ve connected to the MIDI IN connectors. Front Panel 1 2 3 4 5 6 1 2 3 4 5 11 USB Indicator This will light when you’ve connected the UM-3EX to your computer and your computer has detected the UM-3EX. In order for your computer to detect the UM-3EX, you must install the driver and make settings. ( . “Getting Connected and Installing Drivers (Windows)” (p. 14), “Getting Connected and Installing Drivers (Macintosh)” (p. 24)) ¦ ON/OFF Settings of the THRU Switches You can use the THRU switches to select the transmission destinations for MIDI messages from the devices (MIDI keyboard, digital piano, etc.) connected to the MIDI IN connectors. There is no need to change any cable connections. fig.thru-e.eps_60 * Don’t change the setting of a THRU switch while playback is in progress. Doing so will cause MIDI errors. THRU Switch: OFF MIDI messages arriving via the corresponding MIDI IN connector are sent to your computer (sequencer software). Normally, you should use this setting. THRU Switch: ON MIDI messages arriving via the corresponding MIDI IN connector on the UM-3EX are output from the corresponding MIDI OUT/THRU connector of the UM-3EX. Turn this on if you're not using sequencer software. MIDI Message Flow (THRU OFF) MIDI Message Flow (THRU ON) 6 Rear Panel Rear Panel 987 10 1 2 7 8 USB Cable Connect this to the USB connector of your computer. MODE select switch The UM-3EX can be set to function as either the master or a slave device by means of this switch. When using a single UM-3EX unit Select the MASTER setting if you’re using a single UM-3EX unit. When multiple UM-3EX units are connected • Select the MASTER setting for the UM-3EX that’s connected to the computer. • Select the SLAVE setting for UM-3EX units that are connected to the UM-3EX connector (p. 13). * Don’t change the setting of the MODE select switch while the UM-3EX is connected to your computer. First, you need to disconnect the UM-3EX from your computer. Then, once you’ve changed the switch setting, you can reconnect it. * Connection of multiple units is supported only in Windows XP and Mac OS X. For details, refer to “Connecting multiple UM-3EX units” (p. 42). 9 9 UNIT number select switch Specifies the UNIT number (p. 42) of the UM-3EX. If you’re connecting multiple UM-3EX units, you must set each unit’s UNIT number select switch appropriately. Set each UM-3EX to a different UNIT number. * Don’t change the setting of the UNIT number select switch while the UM-3EX is connected to your computer. First, you need to disconnect the UM-3EX from your computer. Then, once you’ve changed the switch setting, you can reconnect it. * Connection of multiple units is supported only in Windows XP and Mac OS X. For details, refer to “Connecting multiple UM-3EX units” (p. 42). 10 UM-3EX connectors Use these when connecting multiple UM-3EX units. * Do not connect any device other than a UM-3EX to the UM-3EX connector. Doing so ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie