Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Yamaha, Modello CL3

Produttore : Yamaha
File Size : 245.88 kb
File Nome :

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere


da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


191) After changing settings in the NETWORK popup window, which is accessed by pressing the SETUP button in the Function Access Area, then pressing the NETWORK button, the CL series must be restarted. NOTE The NETWORK setting is not changed, even if the CL series is initialized. Operation when changing settings in the DANTE SETUP popup window (Reference Manual, p. 198) . When settings have been changed in the DANTE SETUP popup window, the ACCESS indicator lights while the setting changes are stored on the unit. The ACCESS indicator lights when settings for the following are changed. - Parameters in the DANTE SETUP screen - Parameters in the WORD CLOCK screen - Patch settings, Library operations, and AUTO SETUP button operations in the DANTE INPUT PATCH popup window - Parameters in the OUTPUT tab of the I/O RACK screen In order to apply changes to settings in the DANTE SETUP popup window, the unit must be turned off, then on again; however, turn the unit off after the ACCESS indicator turns off. . If the SECONDARY PORT setting or the IDs for the CL series or the I/O rack in the DANTE SETUP popup window has been changed, the units must be turned off, then on again. Follow the steps below to perform the operation. NOTE The SECONDARY PORT and CONSOLE ID settings are not changed, even if the CL series is initialized. Changing the SECONDARY PORT setting 1. Unplug the Ethernet cable from the Dante connectors on the CL series and I/O rack. NOTE When changing the SECONDARY PORT setting, the network topology for the CL series and I/O rack must also be changed. For example, if the setting is changed to DAISY CHAIN while leaving the connection for the REDUNDANT setting, it will no longer be possible to transmit audio. Before changing the setting, first disconnect the cables. 2. Confirm the SECONDARY PORT setting for the CL series and the DIP switch setting on the I/O rack. 3. Turn the CL series and I/O rack off, then on again. 4. After waiting about 1 minute, plug the Ethernet cable into the Dante connector on the I/O rack, and then wait about 20 seconds before plugging the Ethernet cable into the Dante connector on the CL series. Changing the ID 1. Turn off the CL series. 2. Turn the I/O rack off, then on again. 3. Wait about 1 minute, and then turn on the CL series. NOTE If the CL series cannot be turned off, unplug the Ethernet cable from the Dante connector on the I/O rack, turn off the I/O rack while it is disconnected from the network, then turn it on again, and then wait about 1 minute before connecting the Ethernet cable. I/O rack settings for scene recall (Reference Manual, p. 198) For each CL series unit, you can specify which I/O rack the information saved on the CL series will be applied to when the CL series is started up and when a scene is recalled. When there are multiple CL series units, specify the settings so that a scene is recalled to an I/O rack from only one CL series. Follow the steps below. 1. In the Function Access Area, press the S...

Questo manuale è adatto anche per i modelli :
Strumenti Musicali - CL1 (245.88 kb)
Strumenti Musicali - CL5 (245.88 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie