|
da questo dispositivo ha anche altre istruzioni :
Facilità d'uso
Bank Number LSB = 00H Send A Bank Select message is sent at the same time when you selecta tone on the instrument. Modulation Wheel Format Byte 1 Byte 2 Byte 3 BnH 01H vvH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Modulation Depth = 00H to 7FH Portamento Time Format Byte 1 Byte 2 Byte 3 BnH 05H vvH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Modulation Depth = 00H to 7FH Data Entry Format Byte 1 Byte 2 Byte 3 BnH 06H mmH (Data Entry MSB) BnH 26H llH (Data Entry LSB) n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) mm ..... Data entry MSB value for the parameter that is selectedby RPN and NRPN ll .......... Data entry LSB value for the parameter that is selectedby RPN and NRPN Channel Volume Format Byte 1 Byte 2 Byte 3 BnH 07H vvH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Volume = 00H to 7FH Pan Format Byte 1 Byte 2 Byte 3 BnH 0AH vvH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Pan = 00H (left) to 40H (center) to 7FH (right) Expression Controller Format Byte 1 Byte 2 Byte 3 BnH 0BH vvH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Expression = 00H to 7FH Hold 1 (Damper Pedal) Format Byte 1 Byte 2 Byte 3 BnH 40H vvH Recognition n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Hold 1 = 00H to 7FH (00H to 3FH:OFF, 40H to 7FH:ON) Send n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Hold 1 = 00H,7FH(00H:OFF, 7FH:ON) Portamento Format Byte 1 Byte 2 Byte 3 BnH 41H vvH Recognition n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Portamento = 00H to 7FH (00H to 7FH:OFF, 7FH:ON) MIDI Data Format A-2 424A-E-062A PS20_E_MIDI Data.p65 Page 2 02.2.4, 7:13 PM Adobe PageMaker 6.5J/PPC 424A-E-063A A-3 PS20_E_MIDI Data.p65 Page 3 02.2.4, 7:13 PM Adobe PageMaker 6.5J/PPC Sostenuto Format Byte 1 Byte 2 Byte 3 BnH 42H vvH Recognition n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Sostenuto = 00H to 7FH (00H to 3FH:OFF, 40H to 7FH:ON) Send n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Sostenuto = 00H, 7FH (00H:OFF, 7FH:ON) Soft Format Byte 1 Byte 2 Byte 3 BnH 43H vvH Recognition n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Soft = 00H to 7FH (00H to 3FH:OFF, 40H to 7FH:ON) Send n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Soft = 00H, 7FH(00H:OFF, 7FH:ON) Resonance Format Byte 1 Byte 2 Byte 3 BnH 47H vvH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Filter Resonance = 00H to 7FH Release Time Format Byte 1 Byte 2 Byte 3 BnH 48H vvH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ AMP Release Time = 00H to 7FH Attack Time Format Brightness Format Byte 1 Byte 2 Byte 3 BnH 4AH vvH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Filter Cutoff Frequency = 00H to 7FH Portamento Control Format Byte 1 Byte 2 Byte 3 BnH 54H kkH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) kk ........ Source Note Number = 00H to 7FH Effect 1 Depth (Reverb Send Level) Format Byte 1 Byte 2 Byte 3 BnH 5BH vvH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Reverb Send Level = 00H to 7FH Effect 3 Depth (Chorus Send Level) Format Byte 1 Byte 2 Byte 3 BnH 5DH vvH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ Chorus Send Level = 00H to 7FH NRPN (Non-Registered ParameterNumbers) Format Byte 1 Byte 2 Byte 3 BnH 63H pmH (MSB) BnH 62H plH (LSB) n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) pm ...... MSB of NRPNpl ......... LSB of NRPN Byte 1 Byte 2 Byte 3 BnH 49H vvH n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16) vv ........ AMP Attack Time = 00H to 7FH Recognition • NRPN messages not defined by the instrument can also bereceived, but subsequent data entry values after undefinedNRPN messages are ignored. • After the NRPN MSB and LSB are received and the applicablecontrol parameters settings are made, the value is set by receiptof the MSB of the subsequent data entry. The data entry LSB isignored. Vibrato Rate NRPN MSB = 01H NRPN LSB = 08H Data Entry MSB = mmH mm ..... Vibrato Rate = 00H to 40H to 7FH (-64 to 0 to +63) RecognitionWhen the instrument receives this message, the preset Vibrato Ratevalue for the tone is changed to the Vibrato Rate value thatcorresponds to the data entry MSB of the received message. Thereis no change when the value of the data entry MSB is 40H(0). Vibrato Depth NRPN MSB = 01H NRPN LSB = 09H Data Entry MSB = mmH mm ..... Vibrato Depth = 00H to 40H to 7FH (-64 to 0 to +63) RecognitionWhen the instrument receives this message, the preset VibratoDepth value for the tone is changed to the value that correspondsto the data entry MSB of the received message. There is no changewhen the value of the data entry MSB is 40H(0). Vibrato Delay NRPN MSB = 01H NRPN LSB = 0AH Data Ent...