Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Harbor Freight Tools, Modello 38898

Produttore : Harbor Freight Tools
File Size : 1.61 mb
File Nome : 0a129ec9-0bce-408d-87cc-0be586efd1c8.pdf

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


15. DO NOT OPERATE TOOL IF UNDER THE INFLUENCE OF ALCOHOL OR DRUGS. Read warning labels on prescriptions to determine if your judgment or reflexes are impaired while taking drugs. If there is any doubt, do not operate the tool. 16. MAKE SURE ALL EQUIPMENT IS RATED TO THE APPROPRIATE CAPACITY. Do not attempt any operations or hook up any equipment that would not meet the rated capacities of this tool. Page 3 SKU # 38898 Handle ON / OFF Power Switch Pressure Gauge Air Flow Valve Pressure Release Valve Tank Drain Valve Foot Compressor Oil Dipstick Oil Reservoir Oil Drain Plug Air Tank Power Cord Handle ON / OFF Power Switch Pressure Gauge Air Flow Valve Pressure Release Valve Tank Drain Valve Foot Compressor Oil Dipstick Oil Reservoir Oil Drain Plug Air Tank Power Cord Your compressor has a grounded, three-prong plug. If using an extension cord, it must be a three-prong type. You must connect to a three-prong receptacles only. The third prong is for grounding; do not remove or disable the third prong, as this will create an unsafe condition. Common household current is 110-120 Volts. As long as your compressor is rated from 110120 Volts, there will be no complications in using power from a household receptacle. Never try to plug a tool designed for 110-120 Volts into a 220-240 Volt receptacle. 220V plugs and outlets are shaped differently to prevent this. Only use rounded jacket extension cords, preferably listed by Underwriter’s Laboratories (UL). Make sure the cord is rated for outdoor use, even if your application is indoors. Outdoor use cords have the letters “WA” on the cord jacket. The extension cord must have a minimum wire size depending on the amperage of the tool and the length of the extension cord. The size is signified by its AWG (American Wire Gauge) rating; the smaller the gauge, the greater the cable’s capacity. Note: When using extension cords - To avoid circuit breaker and voltage drop problems when using extension cords, we recommend using only 12 gauge x 50 foot extension cords (Item #41444 or #45287), available from Harbor Freight Tools). Page 4 SKU # 38898 Rev 01/02 SET UP & OPERATION Your compressor is fully assembled when you receive it. Before using it, perform the following set up operations. Before using your compressor for the first time, check to be sure the oil reservoir is filled. Note: Optimal oil tank capacity is 7.8 ounces. 1. Unscrew the threaded Oil Dipstick to remove it from the oil reservoir. 2. Look at the oil level on the dip stick. The proper oil level is shown on the illustration to the right. 3. If the oil level is low, add standard, non- detergent 30-weight non detergent compressor oil, (use lighter weight oil for cold weather operation). Add a little at a time, and check the level before each addition. Do not overfill. If overfilled, you can remove the drain plug to allow oil to drain out. 4. When the oil level is correct, replace the dipstick. Next, connect your air hoses, filter and regulator to the compressor, as illustrated in Figure 2 below. Proper Oil Level Oil Dipstick Figure 1. Checking the Oil Level NOTE: Use Pipe Thread Seal tape on all threaded connections. Warning: Fill with compressor oil before using; running with NO or LOW OIL voids warranty. Warning: Do not remove factory sealed Air Flow Valve (#9A); removal of valve voids warranty. Figure 2 — Connecting the Air Compressor 1. The provided air outlet is 1/4” NPT. Connect the high pressure air hose to the air outlet. Note: For easy connection or removal, a quick coupler (included) should be installed on the end of the outlet (a female and a male coupler are also included to use with the quick coupler). 2. For best service, you should incorporate an oiler, a regulator, and a filter in line; as shown in the above diagram. 3. Hoses, Couplings, Fittings, Oilers, Regulators, and Filters are all available from Harbor Freight Tools. Page 5 SKU # 38898 Rev 02/01 REV 03/04 REV 05/05 OPERATION ON / OFF Switch Air Flow Valve 1. Before each use, perform the following checks: Check to be sure the drain valve at the bottom of Note: Always use a 120V electrical source the tank is closed. Check to be sure the oil level (±10% maximum variation). is between the marks on the dip stick. Be sure the safety pressure release valve has not been Pressure Gauge Pressure Release Valve damaged, and is functional. 2. Turn the Air Flow Valve to the OFF position. In the OFF position, the red handle is across (perpendicular to) the line of the air hose fitting. In the ON position, the red handle is parallel with the line of the air hose fitting. 3. Turn ON the compressor, by pulling the Red ON/ OFF Switch up. Turn OFF the compressor by pushing the ON /OFF switch down. 4. Allow the compressor to build up at least 80 PSI as indicated on the pressure gauge. Fig. 3. Controls 5. While the compressor is building up pressure, attach the hoses, fittings, and air tools you will use. 6. When the pressure has reached 80 PSI; open the air flow v...

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie