Log:
valutazioni - 4, GPA: 3.8 ( )

Istruzioni per l'uso Briggs & Stratton, Modello 074001

Produttore : Briggs & Stratton
File Size : 2.47 mb
File Nome : 5f871723-532a-4366-8b1a-31d2c47ef9d5.pdf
Lingua di insegnamento: enesfr
Vai a scaricare



Facilità d'uso


CAUTION, when not used with the safety alert symbol ( ), indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death. Hazard Symbols and Meanings Fire Auto-start Explosion Compressed Air InhalationHot Surface Electrical Shock Flying Objects Air Injection 2 SAFETY RULES WARNING WARNING Failure to read and follow instructions in manual can result in death, bodily injury and / or property damage. • Before using this product, read this Operator’s Manual and follow all Safety Rules and Operating Instructions listed. • Make this manual available to other users of this equipment. Hidden internal tank corrosion can cause violent explosion leading to severe injury and / or property damage. Exceeding pressure rating of attachments or inflatables can cause severe injury and / or property damage. Tampering with or removing ASME safety valve can cause explosion leading to severe injury and / or property damage. • DRAIN TANK after every 4 hours of use or daily by opening drain fitting(s) and tilting compressor to empty accumulated water. • DO NOT modify or repair tank in any way. • DO NOT adjust pressure greater than maximum rating of attachments or inflatables. • DO NOT tamper with or remove ASME safety valve. Check ASME safety valve by pulling ring before each use.ASME safety valve has been set to maximum safe rating. WARNING Contact with compressor or its cord can cause electric shock or burn. Improper grounding can result in electrical shock. Contact with components under protective cover can cause electric shock or burn. • DO NOT use grounding adapters. Inspect cord before each use. • DO NOT operate with protective covers / guards removed or damaged. • DO NOT operate in wet conditions. Store unit indoors. • Disconnect from power source and drain pressure from tank when not in use or before servicing. • DO NOT modify the plug provided. If it does not fit the available outlet, a qualified electrician should install a proper outlet. • A qualified electrician MUST make repairs to the cord set or plug. WARNING Spraying flammable or combustible liquids can cause fire or explosion. Compressor produces sparks during operation, which can ignite flammable or combustible vapors. • DO NOT spray flammable or combustible liquids while smoking, near sparks, open flames, pilot lights, any ignition source, or in confined areas. • Spray in an open, well ventilated area at least 20 feet (6.1 meters) away from compressor or other ignition source. 3 SAFETY RULES WARNING WARNING Compressed air stream from hose or tank drain can cause soft tissue damage to exposed skin and can propel objects leading to severe injury and / or property damage. • DO NOT direct air stream at self or others. • DO NOT attempt to repair air hose(s). • Always wear ANSI Z87.1 approved safety glasses with side shields. Compressed air is not breathable and can cause bodily injury. Some paints or solvents may be harmful if inhaled or ingested, causing severe nausea, fainting or poisoning. • DO NOT use compressed air for breathing. • Always use NIOSH respirator approved for your application when spraying. • Read all instructions with respirator so you are certain it will provide necessary protection against inhaling harmful vapors. WARNING Operating air compressor and tubing are HOT and can cause burns. • DO NOT touch compressor or tubing. • Allow compressor to cool before servicing. WARNING Compressor can start any time when plugged in. • STAY CLEAR • Disconnect from power source and drain pressure from tank when not in use or before servicing. CAUTION Serious damage may result if the break-in instructions are not closely followed. • This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. CAUTION Serious damage may result if operating the unit with insufficient oil. Check oil level daily or with each use. • Damage to equipment resulting from failure to follow this instruction will void warranty. 4 ASSEMBLY ASSEMBLY Carton Contents • Air Compressor • Operator’s Manual • Bottle of Compressor Pump Oil • Oil Dipstick If any parts are missing, call the air compressor helpline at 1-800-743-4115. Your compressor is ready for use after it has been: Properly serviced with supplied oil Connected to a suitable power source Completed the Break-In Procedure Unpacking 1. Remove accessories and packing from carton. 2. Lift unit out of carton. Also Recommended for Use: • Safety Glasses (ANSI Z87.1 approved safety glasses with side shields) • Air Hose - 25 ft (7.6M), 3/8 inch diameter • Quick Connector fittings - Use type I/M quick connect fittings that attach to 1/4 inch NPT thread • Hearing protection (ANSI S3.19-1974) in noisy environments • Respirator (NIOSH-approved) in dusty environments 5 FEATURES AND CONTROLS 6 Air Compressor Pump: Pump compresses air into tanks. Check Valve: When unit is operating, check valve is “o...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie