Istruzioni per l'uso Carrier, Modello 25HCS3C

Produttore : Carrier
File Size : 818.72 kb
File Nome : 25hcs3c-1pd.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (for the most up- --to- --date ratings information. INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 13 SEER/ 10.8 - -- 11.0 EER / 8.0 - -- 8.4 HSPF (nominal) S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 71 dBA S Compressor sound blanket Comfort S System supports Thermidistatt or standard thermostat controls Reliability S Armor Platet coil fin corrosion protection S Front- --seating service valves S Scroll compressor S Internal pressure relief valve S Internal thermal overload S High pressure switch S Loss of charge pressure switch S Filter drier S Balanced refrigeration system for maximum reliability Durability WeatherArmort protection package: S Solid, Durable sheet metal construction S Steel louver coil guard S Color matched ceramic coated cabinet screws S Baked- --on, complete coverage, powder paint Applications S Long- --line - --up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 60 ft. (18.29 m) evaporator above condenser (See Longline Guide for more information.) S Low ambient (down to - --20_F/- --28.9_C)) with accessory kit Warranty S 10 year limited compressor warranty S 5 year limited parts warranty MODEL NUMBER NOMENCLATURE 25HCS3C 1 2 3 4 5 6 7 8 9 10 11 12 13 N N A A A/N N N N A/N A/N A/N N N 2 5 H C S 3 3 6 C 0 0 3 0 Product Series Product Family Tier Major Series SEER Cooling Capacity Variations Open Open Voltage Minor Series 25 = HP H = RES HP C=Comfort S = R-- 22 3=13 SEER C = Coastal 0=Not Defined 0=Not Defined 3=208/230---1 0, 1, 2... REGISTERED ISO 9001:2000 This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. STANDARD FEATURES 48 60 14.0 13.0 XX XX XX XX XX XX XX XX XX Loss of Charge Pressure Switch X X X X X X X X= Standard Feature1824303642MaximumSEERRating15.015.013.113.514.0ScrollCompressorXXXXXLouveredCoilGuardXXXXXFieldInstalledFilterDrierXXXXX FrontSeatingServiceValvesXXXXXInternalPressureReliefValveXXXXXInternalThermalOverloadXXXXXLongLinecapabilityXXXXXLowAmbientcapabilitywithKitXXXXXHighPressureSwitchXXXXX 2 PHYSICAL DATA UNITSIZE---SERIES,VOLTAGE18---3024---3030---3036---3042---3048---30OperatingWeightlb(kg)207(93.9) 204(92.5) 211(95.7) 252(114.3) 239(108.4) 314(142.4) ShippingWeightlb(kg)218(98.9) 236(107.1) 222(100.7) 287(130.2) 250(113.4) 348(157.9) CompressorTypeScrollREFRIGERANTFreon.(R---22) ControlTXV(R---22HardShutoff) Chargelb(kg)6.9(3.0) 6.9(3.0) 6.8(3.1) 8.0(3.6) 9.4(4.3) 13.3(6.0) CONDFANAirDischargeVerticalAirQty(CFM)223326143167333433344046MotorHP1/121/101/51/81/81/4MotorRPM800800800800800800CONDCOILFaceArea(Sqft)19.421.5619.4025.1517.6025.15FinsperIn.202020202020Rows111122Circuits566688VALVECONNECT.(In.)IDVapor5/8”5/8”3/4”3/4”7/8”7/8” Liquid3/8” REFRIGERANTTUBES*(in.)ODVapor(0---80FtTubeLength)5/8”5/8”3/4”3/4”7/8”7/8” Liquid(0---80FtTubeLength)3/8” *Fortubingsetsbetween80and200ft.horizontalor20ft.verticaldifferential,consulttheLonglineGuideline. Note:SeeunitInstallationInstructionforproperinstallation. VAPORLINESIZINGANDCOOLINGCAPACITYLOSS 60- ---30 361 (163.8) 395 (179.2) 16.3 (7.4) 4046 1/4 800 30.18 20 2 11 7/8” 1---1/8 25HCS3C LONG LINE APPLICATION: An application is considered ”Long when outdoor unit is above indoor unit, and 60 ft. (18.28 m) when line” when the total equivalent tubing length exceeds 80 ft. (24.38 the outdoor unit is below the indoor unit. Refer to Accessory m) or when there is more than 20 ft. (6.09 m) vertical separation Usage Guideline below for required accessories. See Longline between indoor and outdoor units. These applications require Application Guideline for required piping and system additional accessories and system modifications for reliable system modifications. Also, refer to the table below for vapor tube operation. The maximum allowable total equivalent length is 250 diameters based on the total length to minimize the cooling ft. (76.2 m). The maximum vertical separation is 200 ft. (60.96 m) capacity loss. Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) Vapor Line Standard UnitNominalSize(Btuh) MaximumLiquidLineDiameters(In.OD)26---50(7.9---15.2) 51---80(15.5---24.4) 81---100(24.7---30.5) 101---125(30.8---38.1) 126---150(38.4---45.7) 151---175(46.0---53.3) 176---200(53.6---61.0) 18,000R---22HP5/8013/40024,000R---22HP5/8013/4007/80030,000R---22HP5/813/407/8036,0003/40R---22HP7/8042,0003/41R---22HP7/8048,000R---22HP3/47/81---1/8Diameters...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie