|
Facilità d'uso
Repairs must not be attempted by untrained and/or unqualified individuals. If service is deemed necessary, contact installing dealer or AquaCal Customer Support at (800) 786-7751. Refrigerant Circuit Service Only by Qualified, EPA Certified Technician WARNING ! Failure to heed the following may result in permanent injury or death. Heater contains refrigerant under high pressure. Repairs to the refrigerant circuit must not be attempted by untrained or unqualified individuals. Service must be performed only by qualified HVAC technicians. Recover refrigerant before opening system. DATA PLATE NOMENCLATURE CHARACTER POSITION NUMBER 1234 5 6 7 8 9 10 120A H x x x x x HEAT OPTIONS: H = Heat Only R = Reversing VOLTAGE: A = 208/230-1-60 B = 208/230-3-60 D = 380/420-3-50 G = 460-3-60 H = 200/240-1-50 MODEL SERIES: 121,120, 135 155 101,111,121,156 Revision Level: General Options: N = None Cabinet color: B = BLACK C = CREAM Refrigerant: E= R22 S = R410A T=R407C Controls: D= Digital 34 SPECIFICATIONS Physical Characteristics 100 & 120 -Applicable Models- 100, 110, & 120 MEASURMENTS SHOWN IN INCHES 35 SPECIFICATIONS Physical Characteristics -Applicable Models- 135 & 155 MEASURMENTS SHOWN IN INCHES 135 & 155 36 SPECIFICATIONS Physical Characteristics -Applicable Models- 101, 111, & 121 MEASURMENTS SHOWN IN INCHES 37 -Applicable Model- 156 MEASURMENTS SHOWN IN INCHES SPECIFICATIONS Physical Characteristics INSTALLATION Placement of Heater -Indoor Installation- Indoor installations can be problematic, and for that reason are discouraged. However, if no viable alternative exists, indoor installations may be successfully accomplished provided very exacting criteria is addressed. Every indoor installation is unique; therefore, there are no specific guidelines for this type of installation. If considering an indoor installation, you are strongly urged to contact the AquaCal Engineering department (800-786-7751) for assistance prior to proceeding. -Outdoor Installation- Service and Operational Clearances: • To operate correctly, heat pumps require large volumes of air moving over the heat collector. allow adequate clearance between the heat pump and walls, fences, shrubs, or other objects. Refer to required clearance drawings below. • Allow five (5) feet of vertical clearance between the top of the heat pump and any roof overhang or other obstruction. This clearance prevents cold discharge air from recirculating back into the heat pump (recirculation would reduce the overall performance of the heat pump). • The access panel requires removal during installation and service. Do not place plumbing, or other items, closer than 30” from the front of the heater. Code Required Clearances: In addition to the previously stated clearance requirements, follow all applicable local, state, and national requirements relative to spacing from other objects or equipment. Required Installation Clearances 12INCHES (SIDE) 12INCHES (SIDE) 30-INCHES (FRONT) TOP VIEW (NO SCALE) (REAR) SQ MODELS, 12-INCHES; ALL OTHER, 6-INCHES RAIN RUN-OFF MUST BE DIRECTED AWAY FROM HEATER. OVERHANG WITH GUTTER 30” MINIMUM CLEARANCE, FRONT 5 FT. MINIMUM CLEARANCE, OVERHEAD SIDE VIEW (NO SCALE) SQ MODELS, 12-INCHES ALL OTHER, 6-INCHES (REAR) FRONT-REAR-OVERHEAD FRONT-SIDES-REAR INSTALLATION -PLACEMENT OF HEATER (continued) Irrigation, Rainwater Runoff, and Landscape Features • Place the heat pump away from direct rain runoff from roofs. If roof slope directs runoff into the heater, a gutter or rain shield will be required on the roof edge above the heat pump. • Relocate or adjust irrigation to avoid water spray directly onto the heat pump. • Do not locate the heat pump directly adjacent to plants, shrubs, or bushes. Doing so will prevent proper air circulation into the unit, and may inhibit access to the heater when service is needed. • Consult drawings on previous page (Required Installation Clearances) for proper spacing to other objects. Equipment Mounting Pad Requirements • The equipment pad shall be constructed of concrete, pressure treated wood, or other code- approved materials. • The equipment pad shall meet all requirements of authorities having code-related jurisdiction. • The pad shall be elevated and placed to provide adequate drainage and support to the base of the heat pump. The pad should be essentially level with just enough pitch to drain condensate and any other water away from the heater. • The pad shall extend–in all directions–(at least) 3" beyond the base of the heat pump. • Under no circumstances shall the heater be installed directly onto the earth. Anchoring Heater to Pad • Follow all relevant local, state, or national requirements regarding wind load anchoring. • When anchoring is required, use AquaCal optional Hurricane Anchoring Kits. -AquaCal anchoring kits satisfy, completely, the very stringent Florida Building Code Section 301.13: Wind Anchoring Requirements. -Contact AquaCal Parts Group (800-785-7751) to obtain the correct anchoring kit ...
Questo manuale è adatto anche per i modelli :attrezzature di pompaggio - 111 (2.64 mb)
attrezzature di pompaggio - 100 (2.64 mb)
attrezzature di pompaggio - 101 (2.64 mb)
attrezzature di pompaggio - 110 (2.64 mb)