Log:
valutazioni - 4, GPA: 4 ( )

Istruzioni per l'uso Lochinvar, Modello BLT2118

Produttore : Lochinvar
File Size : 820.06 kb
File Nome : 98e6bef2-2f84-4360-9554-016736f6b018.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


**Best practice for set point operation. Note: Valve must be installed with proper port orientation. Failure to observe port markings on the valve body prior to installing the valve could result in damage to the unit. *REMOTE SENSOR REQUIRED **REMOTE SENSOR REQUIRED NOTES: 1) Unit(s) high limit must be set at max. 2) Inlet and outlet connections to the boiler are shown for reference only. Actual connections may vary from those represented here. Consult the Installation and Service Manual for actual locations. 3) Unit(s) pump should operate only during firing periods. MIN. 10 PIPE DIA. MIN. 10 PIPE DIA. NOT TO EXCEED 4 PIPE DIA. OR A MAX. OF 12” APART NOTES: 1) Unit(s) high limit must be set at max. 2) Inlet and outlet connections to the boiler are shown for reference only. Actual connections may vary from those represented here. Consult the Installation and Service Manual for actual locations. 3) Unit(s) pump should operate only during firing periods. NOT TO EXCEED 4 PIPE DIA. OR A MAX. OF 12” APART REMOTE SENSOR REQUIRED REMOTE SENSOR REQUIRED REMOTE SEQUENCER MIN. 10 PIPE DIA. INS7238 Rev C 3 of 8 Typical piping applications (cont.): Figure 6_Primary /Secondary Piping of a Single Boiler - 2" Valve Figure 7_Primary/Secondary Piping of Multiple Boilers - 2" Valve for each boiler Note: Valve must be installed with proper port orientation. Failure to observe port markings on the valve body prior to installing the valve could result in damage to the unit. NOTES: 1) Unit(s) high limit must be set at max. 2) Inlet and outlet connections to the boiler are shown for reference only. Actual connections may vary from those represented here. Consult the Installation and Service Manual for actual locations. 3) Unit(s) pump should operate only during firing periods. *Best practice for Indoor/Outdoor reset. **Best practice for set point operation. DETAIL DETAIL NOT TO EXCEED 4 PIPE DIA. OR A MAX. OF 12” APART C = SYSTEM RETURN WATER B = FROM BOILER OUTLET A = BLENDED WATER NOTES: 1) Unit(s) high limit must be set at max. 2) Inlet and outlet connections to the boiler are shown for reference only. Actual connections may vary from those represented here. Consult the Installation and Service Manual for actual locations. 3) Unit(s) pump should operate only during firing periods. NOT TO EXCEED 4 PIPE DIA. OR A MAX. OF 12” APART INS7238 Rev C Typical piping applications (cont.): Figure 8_Primary/Secondary Piping of a Single Boiler - 2 1/2" Valve Figure 9_Primary/Secondary Piping of Multiple Boilers - 2 1/2" Valve for each boiler DETAIL DETAIL Note: Valve must be installed with proper port orientation. Failure to observe port markings on the valve body prior to installing the valve could result in damage to the unit. NOTES: 1) Unit(s) high limit must be set at max. 2) Inlet and outlet connections to the boiler are shown for reference only. Actual connections may vary from those represented here. Consult the Installation and Service Manual for actual locations. 3) Unit...

Questo manuale è adatto anche per i modelli :
attrezzature di pompaggio - BLT2026 (820.06 kb)
attrezzature di pompaggio - BLT2119 (820.06 kb)
attrezzature di pompaggio - BLT2120 (820.06 kb)
attrezzature di pompaggio - GKT2055 (820.06 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie