The starter is required from on motors 5 Hp and above. nOTES warning THE FOLLOWING PAGES CONTAIN OPERATING AND MAINTENANCE INSTRUCTIONS. do not attempt to operate this AIR COMPRESSOR until you have read and understood all safety precautions and instructions listed in this manual. incorrect operation of this unit can cause serious injury!! do not alter or modify this equipment in any manner! preparation INSTRUCTIONS INITIAL SET-UP: 1. Read safety warnings before setting-up air compressor. 2. Ensure the oil level in the air compressor pump is adequate. If low, add SAE-30W non-detergent oil. LOCATION: 1. In order to avoid damaging the air compressor, do not incline the air compressor transversely or longitudinally more than 10°. 2. Place air compressor on a concrete surface at least 12 inches away from obstacles that may prevent proper ventilation. Place the flywheel side of the unit toward the wall. Do not place air compressor in an area: -where there is evidence of oil or gas leaks. -where flammable gas vapors or materials may be present. -where air temperatures fall below 32°F or exceed 104°F. -where extremely dirty air or water could be drawn into the air compressor. 3. Distribute air compressor weight evenly. Excessive vibration can weaken the air tank creating a hazard of explosion. 4. Bolt the air compressor to the concrete surface. a. Mark the areas through the feet of the air compressor where anchor bolts will be placed. b. Move the air compressor and drill holes in the marked areas to accept the anchor bolts. c. With the nut attached, pound the anchor bolts into the pre-drilled holes. d. Remove the nuts and place the air compressor over the anchor bolts. e. Replace and tighten the nuts. WARNING RISK OF EXPLOSION OR FIRE CAUSING SERIOUS INJURY OR DEATH! Do not allow the motor or Motor/ Pressure Switch to come in contact with flammable vapors, combustible dust, gases or other combustible materials. An electric spark may cause an explosion or fire. When using the air compressor for spray painting, place the air compressor as far away from the work area as possible. ANCHOR-DCE preparation INSTRUCTIONS ELECTRICAL: DANGER RISK OF ELECTROCUTION! Improper connection of the equipment-grounding conductor can result in a risk of shock or electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire. 1. A qualified electrician MUST hook up the electrical system. a. Verify the electrical supply at the power source is off. b. Be certain all switches on the Control Panel are in the "OFF" position. c. Make connections to the terminal as shown below. electric diagram_industrial line_1 Phase L1L2L3GL2L1PowerIn1 Phase WARNING RISK OF ELECTRICAL SHOCK! This product must be grounded. If there should be a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. PRE-START CHECKLIST: 1. Check oil level. Add if necessary. 2. Remove any moisture in the air compressor air tank. NEVER attempt to open the Air Tank Drain Valve when more than 10 PSI is in the air tank! Remove excessive pressure with an air tool, then open the Air Tank Drain Valve in the bottom of the air tank. Close tightly when drained. 3. Make sure the Motor/Pressure Switch is in the "OFF" position. 4. Make sure the Safety Relief Valve is working correctly. 5. Make sure all guards and covers are in place and securely mounted. WARNING RISK OF BODILY INJURY! Never attempt to open the Air Tank Drain Valve when more than 10 PSI of air pressure is in the air tank! operatiNG INSTRUCTIONS START-UP: 1. Read safety warnings before performing operation. 2. Move the Motor/Pressure Switch to the "AUTO" position. 3. If you notice any unusual noise or vibration, stop the air compressor and refer to "Troubleshooting". SHUTDOWN: 1. To stop the air compressor, move the Motor/Pressure Switch to the "OFF" position. 2. Drain air from the air tanks by releasing air with an attached air tool or by pulling on the Safety Relief Valve. 3. Once the Air Tank Pressure Gauge registers under 10 pounds, open the Air Tank Drain Valve under the air tank to drain any moisture. 4. Allow the air compressor to cool down, then wipe clean. MAINTENANCE INSTRUCTIONS Read the instruction manual before performing maintenance. The following procedures must be performed when stopping the air compressor for maintenance or service. 1. Turn off air compressor. 2. Open all drains after the tank gauge registers under 10 PSI.. 3. Wait for the air compressor to cool before starting service. WARNING RISK OF BODILY INJURY! Never assume the air compressor is safe to work on just because it is not operating. It could restart at any time! AC Ele. Maintenance ChartMAINTENANCE CHARTPROCEDUREDAILYWEEKLYMONTHLY1000 HOURSCheck pump oil levelXOil leak inspectionX...
Questo manuale è adatto anche per i modelli :attrezzature di pompaggio - AC2-80ES (2.4 mb)