Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso York, Modello 161038-YUM-A-1205

Produttore : York
File Size : 141.39 kb
File Nome : 417da8db-5bbd-4ab5-9d26-154842b4dea6.pdf

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


Federal Guidelines recommend a setting of 78 °F. HEATING - The lower the setting, the lower the amount of energy consumed. Federal guidelines recommend a setting of 65 °F or lower. NOTE: If your cooling and heating temperature adjustments are separate, be sure to set both. 2. After considering “Fan Operation Selection” above, select and set the fan operation mode you desire. 3. Move the comfort control switch to the desired mode of operation (Cooling or Heating) found on your particular thermostat. POWER FAILURE When accidents, wind storms, etc. disrupt electrical power supply to your house, switch thermostat to “OFF” position. SECTION V: SYSTEM OPERATION MANUAL CHANGE-OVER THERMOSTAT COOLING YOUR HOME: With the comfort control switch in the “COOL” position, the system will operate as follows: When the indoor temperature rises above the level indicated by the temperature adjustment setting, the system will start. The unit will operate and the fan will circulate the cooled, filtered air. When the room temperature is lowered to the setting selected, the system will shut off. HEATING YOUR HOME: If your system includes a heating unit and the comfort control switch is in the “HEAT” position, the system will operate as follows: When the indoor temperature drops below the level indicated by the temperature adjustment setting, the system will start. The heating system will operate and the fan will circulate the filtered air. When the room temperature rises to the setting selected, the system will shut off. Whether heating or cooling, the fan will continue to operate if the fan switch was set in the “ON or Intelligent” position. The “AUTO” setting on the fan switch will allow the fan to shut off when your system does. ELECTRONIC THERMOSTAT The computerized electronic thermostat, when programmed, will function automatically to operate the system as follows: When the indoor temperature rises above the higher (COOL) setting, the unit will operate and the fan will circulate the cooled, filtered air. When the room temperature is lowered to the selected level, the system will shut off. The fan will either shut off or run continuously, depending upon your choice of fan switch setting. When the indoor temperature drops below the lower (HEAT) setting, the heating system will operate, and the indoor fan will circulate the heated, filtered air. When the indoor temperature rises to the selected setting, the system will shut off. The indoor fan will either shut off or run continuously, depending upon your choice of fan switch setting. SECTION VI: CARE OF SYSTEM It is strongly recommended that regular periodic preventative maintenance be performed on this equipment. The person most familiar with the equipment in your H.V.A.C. system is a dealer. The dealer can ensure your maintenance program meets the conditions of the Warranty”, maximize the efficiency of the equipment, and service your unit within the federally mandated guidelines with regard to unlawful discharge of refrigerants into the atmosphere. COIL CARE Keep the outdoor unit free of foliage, grass clippings, leaves, paper, and any other material which could restrict the proper air flow in and out of the unit. The coil may be vacuumed to remove any debris from between the fins. If the coil becomes excessively dirty, turn the main disconnect switch to “Off” and wash the coil with your garden hose. Avoid getting water into the fan motor and control box. Flush dirt from base pan after cleaning the coil. SERVICE CALLS There are a few instances where the user can avoid unnecessary service calls. If unit stops functioning properly check the following items before calling your servicing dealer: Unitary Products Group 161038-YUM-A-1205 1. Indoor section for dirty filter. 2. Outdoor section for leaf or debris blockage. Eliminate problem, turn off the thermostat for 10 seconds and attempt start. Wait 5 minutes. If system does not start, call your servicing dealer. FILTER CARE These units are shipped without a filter and is the responsibility of the installer to place a high velocity filter into the return air duct system. Inspect the air filter(s) at least once a month. If they are dirty, wash reusable filters with a mild detergent per manufacturer’s recommendations. Replace disposable filters with new filters. Install the clean filters with “air flow” arrow in the same direction as the air flow in your duct. Filters should be clean to assure maximum efficiency and adequate air circulation. PARTS INFORMATION Replacement parts are available from local contractor/dealer or the nearest distribution center. SECTION VII: SOME EFFICIENCY DO’S & DON’TS DON’T heat or cool unused household area. Reduce supply and return air flow to a minimum in areas which are not living spaces (storage rooms, garages, basements, etc). DON’T be a “thermostat jiggler”. Moving your thermostat setting will not make your system heat or cool any faster. Adjust your thermostat to a comfortable setting and leave i...

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie