Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Acer, Modello Aspire 4252

Produttore : Acer
File Size : 1.32 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


... ... Reviewed ... ... Approved ... 2010. 8. 23 . . 1. UN Transportation Regulation Test 2. Test Procedure 3. Test Result 4. Sample Image -AS10D81 (Nom. 48Wh, 10.8V)- 1. 1. t Test Condition Requirements Test 1. Altitude Simulation Storing at (low pressure)11.6kPa for 6hr at 20+/-5. -Measuring mass before/ after each test (If M>5g, less than 0.1%) -Measuring voltage before/ after each test (more than 90%) -No leakage, no venting, no disassembly, no rupture, no fire Test 2. Thermal Test [75±2.,6hr - -40±2.,6hr,interval max. 30min] x 10cycle Storing at 20±5. for 24h Test 3. Vibration [7Hz-200Hz-7Hz, in 15min] x 12 times x 3 direction 1) sinusoidal waveform with a logarithmic sweep 2) 7Hz 18Hz (maintaining 1gn) app. 50Hz (until 8gn) 200Hz (maintaining 8gn), 1.6mm total excursion Test 4. Shock Half sine shock (peak acceleration : 150gn, pulse duration : 6msec) x 6 (±x, y, z) direction x 3 cycle Test 5. External Short Circuit 100m. ext. short-circuit at 55±2. 1hr continue after returning at 55±2. -No disassembly, no rupture, no fire (after 6 hours) -Temp. monitoring (max. 170.)Test 6. Impact .=15.8mm bar, 9.1kg mass, 61±2.5cm height Test 7. Overcharge Current = Manufacturer’s recommended max. continuous charge current X 2 Voltage 1.If charge voltage . 18V, V (min.) = 2 x (max. charge voltage) or V (min.) = 22V. 2.If charge voltage > 18V, V (min.) = 1.2 x (max. charge voltage) -No disassembly, no fire (after 7 days) Test 8. Forced Discharge Only for Cell, not battery. -No disassembly, no fire (after 7 days) * Tests through T1-T5 shall be conducted in sequence with the same battery. * We declare that the above-mentioned test is the result of being checked according to UN Test ( Manual of Test and Criteria ST/SG/AC.10/27/Add.2) QAE-EF02-100823-PKAS10D81 [UN] Test Report (AS10D81 6cell, S3) 1 / 6 2. 2. e 4 ea 1st cycle Charged 4 ea 1st cycle Discharged 4 ea 50th cycle Charged 4 ea 50th cycle Discharged SampleSample PreparationPreparation Test 2 Thermal Test Test 3 Vibration Test 4 Shock Test 5 Ext. Short Circuit g Test 7 Overcharge Test 8 Forced Discharge * ReportReport 10ea 1st cycle Discharged 10ea 50th cycle Discharged •Forced discharge test is required to cell level, not pack battery level. 4 ea 1st cycle Charged 4 ea 50th cycle Charged Test 1 Altitude Simulation p Test 6 Impact 10ea 1st cycle 50% Charged 10ea 50th cycle Discharged For cylindrical cells, 5 test cells are required. QAE-EF02-100823-PKAS10D81 [UN] Test Report (AS10D81 6cell, S3) 2 / 6 3-1. T1-T4 Test Result Before Altitude (T1) Thermal (T2) Vibration (T3) Shock (T4) Pack NO. OCV Mass OCV Mass Residual OCV(%) Mass Loss(%) Result OCV Mass Residual OCV(%) Mass Loss(%) Result OCV Mass Residual OCV(%) Mass Loss(%) Result OCV Mass Residual OCV(%) Mass Loss(%) Result A. 1st cycle fully state Charge 4 3 2 1 11.956 11.979 11.982 11.954 342.10 341.25 341.30 341.20 11.923 11.906 11.913 11.949 342.10 341.25 341.30 341.20 99.99 99.99 99.98 99.98 0.017 0.008 0.008 0.008 Pass Pass Pass Pass 11.900 11....

Questo manuale è adatto anche per i modelli :
Notebook - Aspire 4250 (1.32 mb)
Notebook - Aspire 4253 (1.32 mb)
Notebook - Aspire 4253G (1.32 mb)
Notebook - Aspire 4333 (1.32 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie