|
Facilità d'uso
02- The fitting is not suitable for installation in bathrooms at least not in the specified zone. 03- The fitting is suitable for fixing to normal flammable surfaces. Recessed luminaires should under no circumstances be covered with insulation material or other similar materials. 04- This product is not suitable for direct mounting on flammable surfaces. 05- The fitting may be covered with insulating material. 06- The fitting is only suitable for fixing to the ceiling. 07- The fitting is only suitable for fixing to the wall. 08- The fitting is suitable for fixing to the wall and to the ceiling. 09- Always observe the minimum distance between the lamp and the surface being lit as indicated on the icon. 10- IPX1: The fitting is protected against dripping water. 11- IPX3: the fitting may be exposed to raindrops (falling drops under a maximum angle of 60° to the vertical axis). 12- IPX4: the fitting is splash-proof: it may be exposed to splashing water coming from any direction (360°). 13- IPX5: The fitting is protected against water jets. 14- IPX7: The fitting can be installed into the ground. 15- IPX8: offers protection against immersion up to the indicated depth. 16- IP5X: The fitting is dust protected. 17- IP6X: The fitting is dust tight. 18- Immediately replace a cracked or broken safety glass and use only manufacturer approved parts. 19- Protection class I: the fitting has an earthing connection. The earth wire (yellow/green) has to be connected to the clip marked with . 20- Protection class II: the fitting is double insulated and must not be connected to an Earth. 21- Protection class III: the fitting is only suitable for very low voltage supply (e.g. 12V). 22- Strip the wire as indicated in the diagram. 23- The earthing wire always has to be longer than the contact wires. 24- The use of the supplied heat-resistant sleeving is required over the unstripped wire lengths. 25- Use heat-resistant cable for wiring the fitting into the mains. 26- The fitting is only suitable for wiring directly into the mains. 27- X-connection: In case of damage to the wire, it has to be replaced by a wire of the same type. Y-connection: In case of damage to the wire, it has to be replaced only by the manufacturer, distributor or by an expert, to avoid risks. Z-connection: The wire can’t be replaced. 28- MAX. …W: only use lamps suitable for this fitting and keep within the maximum specified wattage. 29- The fitting is only suitable for reflector lamp(s). EN SAFETY INSTRUCTIONS - PART B 30- The fitting is only suitable for PLCE lamps. 31- The fitting is not suitable for PLCE lamps. 32- Only an incandescent lamp with a diameter of 60mm can be used. A lamp with a 45mm diameter must not be used for this fitting. 33- Only use an incandescent globe bulb that is the size of the indicated diameter. Never use a standard incandescent bulb. 34- This product is only suitable for candle shaped bulbs. 35- Never use "cool-beam" lamps for this fitting. 36- The fitting is only suitab...
Questo manuale è adatto anche per i modelli :Illuminazione - 172470616 (1.5 mb)
Illuminazione - 162549316 (1.5 mb)
Illuminazione - 162548716 (1.5 mb)
Illuminazione - 162539316 (1.5 mb)