Log:
valutazioni - 2, GPA: 5 ( )

Istruzioni per l'uso Cleveland Range, Modello OEB-12.20

Produttore : Cleveland Range
File Size : 119.84 kb
File Nome : 48338572-1627-4fd7-adc0-b6ad2255fd28.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


"DisappearingDoor".Capacityfortwelve(12)18"x26"fullsizesheetpans, ortwenty-four(24)12"x20"x21/2"pans. MODEL:OEB-12.20CAPACITY:Twelve(12)-18”by26”by1”fullsizesheetpans*orTwenty-four(24)-13”by18”by1”halfsizesheetpans*orTwenty-four(24)-12”xby20”by21/2”steamtablepans*Onwireracks.Additionalwireracksrequiredformaximumcapacity. ELECTRICHEATED–withSteamGenerator 1333 East 179 St., Tel: 1-216-481-4900 Web Site: Cleveland, Ohio, U.S.A. 44110 Fax: 1-216-481-3782 Email: Steam@ClevelandRange.com 48.51" 2.52" 1.58" 46.70" 9.06" 2.80" 56.15" FRONT VIEW 48.51" 2.52" 1.58" 46.70" 9.06" 2.80" 56.15" FRONT VIEW The "Advanced Closed System" offers the following advantages: ¦ Saves energy ¦ Automatic moisture level adjustment ¦ Low heat and steam emission to the kitchen ¦ Automatically regulated steam injection ¦ Enables immediate change into the steam mode ¦ "Crisp & Tasty" demoisturizing function Model: OEB-12.20 Pan Capacity [Unit (trolley) has 12 slide rails at 2.64" (67mm) apart]: 12 (20" x 26") full size wire racks 12 (18" x 26") full size sheet pans -on wire racks 24 (13" x 18") half size sheet pans -on wire racks 24 (12" x 20" x 2 1/2") steam table pans 24 (12" x 20" x 1") steam table pans 24 (12" x 20") frying baskets -(no wire racks needed) For Banquet Operations: Optional Plate Rack holds 74 plates Unit Dimensions: Width -53.83", Depth -44.34", Height -57.73" Shipping Dimensions: (including packaging) Width -60", Depth -50", Height -66" Shipping Weight: 717 Lbs (including trolley) 3.39" 41.54" 2.80" 12.68" 2.80" 13.08" SAV Required Clearances: Rear -2", Left Side -4", Right Side -2 1/2" • Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit. • Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations). • Installation must comply with all local fire and health codes. Agency Approvals: UL, UL -Sanitation (NSF Standards) Electrical Requirements: 208/3/60 Total Connected Load: 26.3 KW Hot Air: 25.8 KW Steam Generator: 23.1 KW Amps per Phase: 77.8 Do not connect to a G.F.I. outlet TOP VIEW 31.50" 240/3/60 440/3/60 480/3/60 34.9 KW 29.4 KW 34.9 KW 34.3 KW 28.8 KW 34.3 KW 30.7 KW 25.8 KW 30.7 KW 88.8 41.4 44.9 Water Connections: Cold Water (drinking water quality) Flow Pressure: 30 -60 PSI Water Inlets: W1W23/4" GHT-F (Female Garden Hose Connection) Treated Water for Steam Generator Untreated Water for Condenser and Hand Shower Drain Connection: 2" Tube Venting: Exhaust Hood required D AV Air Vent RCCSS *Connection for Cleaning Solution *Connection for Rinse Cycle Low Pressure Safety Valve 5.48" *Available as an option BOTTOM VIEW 3.08" 14.26" 10.87" 42.29" 3.15" 6.50" 25.79" 18.90" 2.96" 27.29" 1.19" 29.57" 3.00" 4.97" RCCSW1W2D NOTES: Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. SECT. IIA PAGE 12 Cleveland Range equipment is built to comply with applicable standards for manufacturers. ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie