Log:
valutazioni - 4, GPA: 5 ( )

Istruzioni per l'uso JVC, Modello 0200JTMMDWJSCEN

Produttore : JVC
File Size : 478.91 kb
File Nome : 776f050a-b3d0-4244-ae25-51e8ed27eda9.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


English 16 EnglishEnglish Continued Recording the External Equipment When recording from the external equipment, you can select one of the two recording methods — Manual Recording and Sound Synchronized Recording. • Manual Recording — Sound is recorded in stereo (both on the left and right audio channels). You have to operate the MD recorder and the external equipment respectively. • Sound Synchronized Recording — With this method, you can start recording when the sound signals come into the MD recorder (sound is recorded in stereo). Sound Synchronized Recording will stop automatically if no sound comes in for more than 30 seconds. If Sound Synchronized Recording will not work correctly Use the Manual Recording. Sound Synchronized Recording starts automatically when the MD recorder detects sound signals come in. If sound signal is too weak for this unit to detect, Sound Synchronized Recording will not start (or will stop even while the source is being played). Recording the External Equipment Manually First of all, make sure the proper cable connections between XM-G6 MD recorder and external equipment (see also page 6 in this manual, and refer to FS-G6’s Instructions pages 9). 1 Insert a recordable MD. The MD IN lamp lights orange. 2 Press AUX button to select either analog source or digital source according to the external equipment. Each time you press AUX button, AUX mode changes between “AUX” and “AUX DIGITAL” alternately. AUX AUX DIGITAL 3 Press REC PAUSE button on the MD recorder. The REC indicator on the MD recorder lights red, and the MD recorder switches to the recording-pause mode. 4 Press 6 (play/pause) button on the MD recorder or MD 6 (play/pause) button on the remote control. Selected source and remaining time for recording appear in the display window as follows: or 5 Make the external equipment start playback in succession. • To stop recording temporarily, press REC PAUSE button or 6(play/pause) button on the MD recorder or MD 6(play/pause) button on the remote control. • To resume recording, press 6(play/pause) button on the MD recorder or MD 6(play/pause) button on the remote control again. Each time you press DISPLAY/CHARA. button, information switches between the remaining time for the MD and the elapsed time for the MD alternately. 6 Press 7 (stop) button on the MD recorder to stop recording as required. “WRITING” appears in the display window, and you can remove the MD by pressing 0(eject) button. 17 EnglishEnglish Recording the External Equipment — Sound Synchronized Recording Setting the recording mode, you can start playing back the external equipment and recording from it onto an MD simultaneously. First of all, make sure the proper cable connections between XM-G6 MD recorder and external equipment (see also page 6 in this manual, and refer to FS-G6’s Instructions page 9). 1 Insert a recordable MD. The MD IN lamp lights orange. 2 Press AUX button to select either analog source or digital source according to the external equipment. Each time you press AUX button, AUX mode changes between “AUX” and “AUX DIGITAL” alternately. AUX AUX DIGITAL 3 Press REC MODE button to select recording mode as follows: 4 Press SET button to start recording from the external equipment. Selected source and remaining time for recording appear in the display window as follows: or • To stop recording temporarily, press REC PAUSE button or 6(play/pause) button on the MD recorder or MD 6(play/pause) button on the remote control. • To resume recording, press 6(play/pause) button on the MD recorder or MD 6(play/pause) button on the remote control again. Each time you press DISPLAY/CHARA. button, information switches between the remaining time for the MD and the elapsed time for the MD alternately. • If no sound comes in for more than 30 seconds, Sound Synchronized Recording will stop. “WRITING” appears in the display window, and you can remove the MD by pressing 0(eject) button. 18 Editing an MD English Introducing MD Editing Functions A recorded MD can be edited in many ways. The MD editing functions include dividing, joining, moving, erasing single tracks, erasing the entire disc, and more than one of them can be combined as required. Dividing a track (DIVIDE) : Page 20 This function divides a track by adding a track marking(s) in the desired point(s) in the middle or where you want to search later. 1st 2nd 3rd 4th Track No. After track B division 1st 2nd 3rd 4th 5th B CA D E C DA B E Joining a track (JOIN) : Page 21 This function joins two adjacent tracks into a single track by deleting a track marking. 1st 2nd 3rd 4th 5th Track No. After track B joining 1st 2nd 3rd 4th C D EA B C D EBA Moving a track (MOVE) : Page 22 This function moves a track by reordering the track numbers. 1st 2nd 3rd 4th 5th Track No. After track B movement 1st 2nd 3rd 4th 5th C D EA B C D E A B Erasing a track (ERASE) : Page 22 This function erases specified tracks. After the erasure, the subsequent tracks are justified and their trac...

Questo manuale è adatto anche per i modelli :
Lettori - LVT0378-001A (478.91 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie