|
Facilità d'uso
PLEASE READ THESE INSTRUCTIONS BEFORE USING THIS APPLIANCE IMPORTANT : SAVE OWNERS MANUAL FOR THE LOCAL INSPECTORS USE CUSTOMER: KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE FOR USE IN USA/CANADA 12/06 EINS 513307 CONTENTS SECTION PAGE INSTALLATION 3 GENERAL NOTES 4 INSTALLATION 4 APPLIANCE DIMENSIONS 5-6 ELECTRICAL 7 INSTRUCTIONS 7 ELECTRICAL TEST PROCEDURE 7 WIRING DIAGRAM 8 USERS GUIDE 9 SAFETY PRECAUTIONS 10-11 RANGE ACCESORIES 12 HEAT INDICATOR 12 THERMOSTAT CONTROL 12 SERVICING 13 OPERATING YOUR AGA 13 FITTING OF OVEN SHELVES 14 REMOVAL OF OVEN SHELVES 15 CLEANING & CARING FOR YOUR AGA 16 GUIDE TO AGA COOKING 16 2 Installation Section Remember, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by AGA-RANGES. CAUTION: THIS UNIT IS HEAVY, PROPER EQUIPMENT AND ADEQUATE MANPOWER MUST BE USED IN MOVING THE RANGE TO AVOID DAMAGE TO THE UNIT OR THE FLOOR 3 GENERAL NOTES NOTE: THESE INSTALLATION INSTRUCTIONS SHOULD BE LEFT WITH THE APPLIANCE AND THE USER TO RETAIN FOR FUTURE REFERENCE. The Aga range is delivered unassembled. Before installation can be made, the site is inspected for suitability by an authorised Aga distributor and corrected where necessary to conform with local installation codes or in the absence of local codes with: NATIONAL ELECTRICAL CODES ANSI/NFPA 70 Assembly is undertaken on site by the same Aga distributor to ensure correct performance and safety. INSTALLATION THE INSTALLATION OF THIS APPLIANCE MUST NOT BE LESS THAN 12mm FROM ANY SURFACE. With specific exceptions, the installing of any type of Aga Range is subject to the respective directions contained in current issue of the local Building Regulations. In addition, planning permission may need to be obtained, which should be applied for separately. The complete range is floor-mounted and the space in which the appliance is to be fitted must have the following minimum dimensions: A minimum clearance of 60mm is required above the raised insulating cover handle. Side clearance zero unless range is fitted against a wall, where 116mm is required at the right hand side for oven access. In addition a minimum clearance of 1000mm must be available at the front of the cooker to enable the cooker to be serviced. To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally, a minimum of 5” beyond the bottom of the cabinets. NOTE: AGA RANGES ARE DELIVERED EX-WORKS UNASSEMBLED. ASSEMBLY IS UNDERTAKEN BY THE AUTHORISED AGA DISTRIBUTOR/SPECIALIST. Range Base or Hearth It is essential that the base or hearth on which the range stands should be level and be capable of supporting the total weight of the range. Model EC-LM - 406 Kg EE-LM - 584 Kg The top of the hearth must be of non-combustible material for a minimum thickness of 12mm. The wall behind the range must be of non-combustible material for a minimum thickness of 25mm. Tiling When the range is to stand in a recess, or against a wall which is to be tiled, in no circumstances should the tiles overlap the cooker top plate. Installation Requirements The installation of the range must be in accordance with the relevant requirements of the local wiring and building regulations. It should be in accordance also with any relevant requirements of the local authority. In your own interest, and that of safety to comply with the law, all appliances should be installed by an authorised Aga distributor, in accordance with the relevant regulations. 4 A B C D F G H K L R S T 116 55 114 mm 987 889 851 679 1330 756 1125 12 698 EC-LM MODEL Fig. 1 EC-LM MODEL Fig. 1 5 Fig. 1B EE-LM MODEL A B C D F G H K L R S T 116 55 114 mm 1487 889 851 679 1330 756 1125 12 698Fig. 1A EE-LM MODEL A B C D F G H K L R S T 116 55 114 mm 1487 889 851 679 1330 756 1125 12 698Fig. 1A 6 ELECTRICAL CONNECTION An electrical socket must be provided within 6 feet of the LH side of the appliance and easily accessible to the user to disconnect. Do not position socket above the appliance. Electric Shock Hazard Electrical Grounding is required on this appliance. Do Not connect to the electrical supply until the appliance is permanently grounded. Disconnect the power to the junction box before making the electrical connection. This appliance must be connected to a grounded, metallic, permanent supply or a grounding connector should be connected to the grounding terminal or wire lead on the appliance. Failure to follow these instructions could result in death or serious injury. • A four-wire single phase 240-volt, 60-Hz, AC-only electrical supply is required on a separate, 30-amperes circuit, fused on both sides of the line. (See Fig. 2A - for wiring details). • A t...
Questo manuale è adatto anche per i modelli :Piastra - EE LM-4 (240.25 kb)