|
Facilità d'uso
It is recommended that insulated 18-gauge wire be used to achieve optimal performance (ten feet of wire is furnished with the thermostat). If the thermostat has to be placed farther away from the stove, it is recommended that a larger gauge wire be used. It is a good idea to leave some extra wire behind the stove so the unit can be moved out for cleaning. Mount the thermostat level for proper operation, and follow the manufacturer’s directions for installing this part. Text Box: Text Box: Appropriate Clearances for Vented Gas Unit Installation SECTION V: BLOWER The blower is standard on your vented gas fireplace heater and provides 100 CFM of circulating air capability – it operates on 115 volts AC, 60 HZ power source and draws 1.5 AMPS. The blower is attached to the rear of the stove with four (4) screws. Blower activation is achieved with a temperature switch that mounts to the back of the firebox. When the back wall of the stove heats up, the blower will activate and when it cools down, the blower will automatically shut off. The blower will activate at the speed as set on the variable speed dial. SECTION VI: OPERATING INSTRUCTIONS WARNING Children and adults should be alerted to the hazards of high surface temperatures of the appliance and should stay away to avoid burns or ignition of clothing. Young children should be carefully supervised when they are in the same room as the appliance. CAUTION •If the door is removed for service it must be replaced prior to operating this appliance. •Clothing or other flammable material should not be placed on or near the appliance. •Before operating this heater, please review the safety precautions given earlier in the manual. •Check the logs for proper location. •Check for gas leaks – soap and water can be used to expose suspected leaks. •Verify that the connector pipe and chimney is unobstructed. •Be sure the door is properly sealed. •When installing the blower, check all connections to avoid electrical shock. •Open the gas valve access door to get to the valve; this will also expose the instructions. FOR YOUR SAFETY READ BEFORE LIGHTING 1. This appliance is equipped with a manual piezoelectric ignition device. Do not try to light the pilot by hand. 2. Before lighting, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. 3. Use only your hand to turn the gas valve control knob. Never use tools. If the knob will not turn by hand, do not try to repair it, but call a qualified service technician. Force or attempt to repair may result in fire or explosion. 4. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas valve control that has been under water. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s telephone. • Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. Text Box: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. LIGHTING INSTRUCTIONS 1. STOP! Read “For Your Safety” above. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with a manual piezoelectric ignition device. Do not attempt to light the pilot by hand. 5. Turn gas valve control knob fully clockwise > to “OFF.” 6. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow the “For Your Safety Read Before Lighting” information earlier. If you do not smell gas, go to the next step. 7. Be sure the thermostat is set at the lowest setting. 8. Turn the gas valve control knob counterclockwise < to “PILOT.” 9. Push in the gas valve control knob and hold it in while pushing the button of the piezoignitor. Push the piezoignitor button several times while holding the gas valve control knob in. 10. After the pilot has ignited, you may cease pushing the piezoignitor button. Continue to hold the gas valve control knob for approximately 30-60 seconds. Release the gas valve control knob and it will “pop” out. If the knob does not pop up when released, stop and immediately call your service technician or gas supplier. The pilot is now lit. 11. For the very first lighting, it may take several attempts to purge air from the gas line. If pilot ignition does not occur or the pilot goes out, repeat steps 9 and 10. 12. Turn the gas valve control knob fully counterclockwise < to “ON.” 13. Turn on all power to appliance. 14. Set thermostat to desired setting. 15. If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” and call your service technician or gas supplier. 16. Shut the gas valve...
Questo manuale è adatto anche per i modelli :Piastra - 26-GBVLP (289.42 kb)
Piastra - 60-SHBVLP (289.42 kb)
Piastra - 60-SHBVNG (289.42 kb)
Piastra - 60-TRBVNG (289.42 kb)