Log:
valutazioni - 1, GPA: 5 ( )

Istruzioni per l'uso Avanti, Modello G24AW

Produttore : Avanti
File Size : 795.4 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


The inlet pressure of the gas supply shall be in accordance with the nominal inlet pressure of the regulator used on the range or 1/2 psi {3.5 kPa) pressure maximum. On the factory setting for Natural Gas operation, the pressure regulator will regulate the pressure to 6 inches water column pressure. When set for LP-Propane gas operation, it will regulate the pressure to 10 inches water column pressure. To change the pressure regulator setting: • Unplug the main supply cord of the range. • Unscrew the cap on the pressure regulator • Lift out cap and turn it over. If set for LP-Propane gas operation, the cap must show "LP". If set for Natural Gas operation, the cap must show none. • Place the cap on pressure regulator and tighten. (See Figure 1) > Conversion of Burner Valves • Unplug the main supply cord of the range. • Remove burner control knobs from range by pulling them out. • Remove the screws on the front surface of control panel. • Remove two screws located on the bottom surface of control panel. • Pull out the control panel. ? • Using a small screwdriver, loosen or tighten the screws located on each valve. If set for LP-Propane gas operation, the screws must be tightened fully. In the factory setting for Natural Gas operation, the screws must be loosened by turning them counterclockwise • 3/4 turn. • Replace the control panel and screws. • Replace the control knobs. (See Figure 2) 1 Figure 2 16011O7SRO Figure 3 Converting Surface Burners • Unplug the main supply cord of the range. • Remove the rings of surface burners. • Pul) up the burner rings with their caps and unscrew the orifices using a 7mm-spanner socket.(See Figure 3) • Use orifices located on the information card in a plastic bag at lower rear side of the range. In order to choose the required orifice for particular burner and gas type; see the mark located on orifices and look at the information card. • Screw each orifice to proper matching burner. • Place the burner rings to their original locations. Be careful that the burner rings are level with the surface of the main top. • Keep the remaining orifices in their plastic bag for future use. (See Figure 3 and Table 1) BURNERS LP GAS * NATURAL GAS RAPID 0.92 1.40 SEMI-RAPID ! 0.65 0.97 SIMMER ! 0.50 0.75 OVEN ! 0.90 1.32 BROILER* i 0.90 1.32 Table 1 - Marks on orifices Conversion of Oven Burner • Unplug the main supply cord of the range. • Open oven door. • Remove the bottom panel of oven. Do this by pushing it backwards, then lifting the front edge up and out as shown in Figure 4. • Undo the screw, which holds the burner in place, and remove the burner completely. (See figure 5) • Loosen and remove the orifice at the bottom rear of oven. Using a 7mm-spanner socket. Replace the orifice supplied with the range. For the mark of orifice, see Table 1. • Loosen the retaining screw on the burner ringT If setting for LP-Propane gas operation, slide the ring towards the burner to open the burner hole completely. In the factory setting for Natural Gas operation, the ring must be located in a place that maintains a gap of 1/6". (See Figure 6) • Replace the burner in the oven and replace the screw. Replace the bottom panel of oven. i 15011075. RO > Converting of Broiling Burner • Unplug the main supply cord of the range. • Remove the screw and washer holding the burner in place (See Figure 7). • Pull out the burner until it releases. • Remove the orifice using a 7mm-spanner socket. Replace the orifice supplied with the range. For the mark of orifice, see Table 1. • Replace the burner and the guard in the oven. Replace the washer and tighten the screw. Be sure that the guard sits completely in place while doing this. • Keep the remaining orifice in its plastic bag for future use. > Gas Connection • Gas connection must be made in accordance with local codes or in absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-Latest Edition. • Connect gas supply to regulator using a flexible connector, as shown in Figure 8. Pressure regulator supplied with this range has a 1/2-inch NPT female connection. • A manual shutoff, not supplied with this range, must be installed in an accessible location outside of the range. • Use joint compound that is resistant to action of natural or propane gas on alt male pipe threads. • Use supplied pressure regulator only. • Do not over tighten gas fitting when attaching to pressure regulator. Over tightening may crack regulator. • Appliance and individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). • Appliance must be isolated from gas supply piping system by loosening manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa). • Gas supply pressure for checking regulator setting must be at least 1 -in...

Questo manuale è adatto anche per i modelli :
Piastra - DG24CSS (795.4 kb)
Piastra - DG24CW (795.4 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie