Log:
valutazioni - 2, GPA: 3.5 ( )

Istruzioni per l'uso Hearth and Home Technologies, Modello 3500L

Produttore : Hearth and Home Technologies
File Size : 3.3 mb
File Nome : MagnumCS%20Owner%20manual%200803%20rev9.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS BIOMASS CORN/ WOOD PELLET BURNING STOVE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. IMPORTANT: Always contact your local dealer/installer with questions before contacting the factory. When you call have your serial number, purchase date, who installed the unit and a list of questions. This appliance must be installed by a qualified/trained factory approved installer to assure proper operation/warranty. AMERICAN ENERGY SYSTEMS, INC. GRANTS NO WARRANTY, IMPLIED OR STATED, FOR THE INSTALLATION OR MAINTENANCE OF THE STOVE AND ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S). AMERICAN ENERGY SYSTEMS, INC. -150 Michigan Street SE - HUTCHINSON, MINNESOTA 55350 Web Site: Rev. date 08/06 .. When installing your Countryside Biomass Corn/Pellet stove, particular attention needs to be made in regards to fire protection. If the unit is not properly installed, a house fire may result. For your safety, follow the installation and operation instructions provided, and if a question arises contact local building or fire officials about restrictions and installation requirements in your area. .. Read the operations and fuel section of this manual before plugging in your unit. .. Always unplug the unit before attempting any service work. .. Do not connect the unit to a chimney flue already serving another appliance. .. When installing the chimney pipe to the unit, it is important to remember that the unit operates on a negative pressure and the chimney on a positive pressure. All chimney connections, elbows and fittings must be airtight. (proper venting practices must be followed. Consult with a venting professional) .. Ashes must be disposed of in a metal container with a tight fitting lid. .. All minimum clearances to combustibles must be followed. .. The Countryside Biomass Corn/Pellet Stove is tested for operation with 14% or less moisture corn or with wood pellets with an ash content of no more than 3%. It is recommended that Corn with 11-12% moisture or wood pellets with an ash content of 1% or less be used for efficient operation of this unit. Corn over 12% moisture has a lower BTU value and will be hard to burn on the lower settings. .. It is important to use fuel that is clean, dry and consistent. Make sure that your supplier is giving you the same fuel each time that you purchase. It is recommended that you purchase your entire heating season supply of fuel at one time so that the fuel will be the same. .. A voltage surge protector or ground fault outlet is required for this unit. The electrical warranty will be voided if surge protection is not installed before operating this unit. .. A grounded outlet must be provided with proper polarity. A constant 115 volt, 60 cycles must be provided for proper operation or the warranty of this appliance will be forfeited. .. DISCLAIMER NOTICE: No guarantee is made regarding the heating capacity of this product. The actual area that this unit will heat depends on factors such as building conditions, heat loss, type of construction, amount and type of insulation, type of air movement and heat distribution and the location of the product. .. IMPORTANT: Your home must be checked to verify that there is no negative pressure that will effect the operation of this appliance. OWNER’S MANUAL Installation – Operation – Maintenance Instructions NOTE: These instructions must be saved TABLE OF CONTENTS PAGE CLEAN BURN (special additive) ………………………………………………..………….. 3 INTRODUCTION & SPECIFICATIONS………….……………………………………….... 4 IMPORTANCE OF ADEQUATE FRESH AIR……..………………………………………. 5 SAFETY STEPS…………………………………………………………………………….. 6 BURNING SOLID FUELS (SHELLED CORN/WOOD PELLETS)………………………... 7-8 UNPACKING YOUR COUNTRYSIDE STOVE……………………..……………………... 8 INSTALLATION REQUIREMENTS (FLOOR PROTECTION)………………..………..... 9 CLEARANCES TO COMBUSTIBLES……………………………………………………… 10 GUILDELINES FOR EXHAUST SYSTEMS DESIGNS…………………………………… 11-12 DESIGN GUIDELINES FOR OUTSIDE COMBUSTION AIR CONNECTION…………... 13 INSTALLATION PRECAUTIONS………………………………………………………….. 14 VENT TERMINATION GENERAL INSTRUCTIONS…………………………………….. 15 INSTALLATION CONFIGURATIONS…………………………………………………….. 16 ALCOVE INSTALLATION REQUIREMENTS………………………………………..….. 17 FREESTANDING STOVE INSTALLATION CONFIGURATIONS………………………. 18-20 FIREPLACE INSERT INSTALLATION CONFIGURATIONS……………………………. 21-22 GLASS MAINTENANCE………………………………………………………………..….. 23 STOVE CONTROLS…………………………………………………………………………. 24 LIGHTING INSTRUCTIONS………………………………………………………………... 25 CIRCUIT BOARD FUNCTIONS……………………………………………………………. 26 SETTING THE DRAFT……………………………………………………………………… 27 MAINTENANCE INSTRUCTIONS……………………………………………………….. 27-30 AUTOMATIC SAFETY FEATURES……………………………………………………….. 31 HOPPER AUGER SAFETY SWITCH LOCATION………………………………………… 32 THERMOSTAT INSTALLATION…………………………………………………………... 33 TROUBLE SHOOTING GUIDE…………………………………………………………….. 34-37 WIRING DIAGRAM……………………………………...

Questo manuale è adatto anche per i modelli :
Piastra - 3500P (3.3 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie