Log:
valutazioni - 1, GPA: 5 ( )

Istruzioni per l'uso Ariston, Modello DB62

Produttore : Ariston
File Size : 356.41 kb
File Nome : DB62IX_19505188901.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


! Read these instructions carefully; the following pages contain important information on installation and suggestions on how the appliance works. ! Ensure that the oven is installed by a qualified registered installer, in accordance with the latest local regulations using the following instructions. ! Before connecting or installing the oven the electricity supply must be switched off. Where to put your oven . Your oven should not be located adjacent to a gas hob/heater or eye level grill as flames from the burners could cause damage to your oven. . For your own safety and to get the best results from your oven it is important to read through this instruction booklet before using your oven for the first time, including the Always and Never safety warnings (see For Your Safety). ! Incorrect installation could affect the safety of the oven. ! This appliance must be earthed. . The installer must check that the voltage shown on the rating plate corresponds with the house electricity supply. . The oven must be supplied via a suitable double pole isolating switch, having a contact separation of at least 3 mm in all poles placed in a readily accessible position adjacent to the unit. . The maximum loading for your oven is 5.3kW. . After unpacking the oven stand it on the packing base in order to avoid damage. Electrical connections ! Ensure that the electricity supply is turned OFF before installing your appliance. . Remove the terminal cover at the rear base of the oven. Pass the cable through the cable clamp and connect to the appropriate terminals provided. Allow sufficient cable so that the oven can be set down on the floor whilst still connected up. Tighten the screws on the cable clamp and replace the terminal cover. Make mains connections. This appliance conforms to EN55014 regarding suppression of Radio and Television reception interference. Where a double oven is used a 32 amp double pole control switch should be used to feed the unit using a suitable rated cable. We recommend that a minimum of 4mm2 PVC insulated twin and earth cable is used. . Where a hob is fitted adjacent to an oven then a 45 amp Double Pole control switch should be used to feed both units via separate suitably rated cables. We recommend that a minimum of 4mm2 PVC insulated twin and earth cable is used. ! Children should not be allowed to play with the appliance or tamper with the controls. ! IMPORTANT DO NOT LIFT OVEN BY THE DOOR HANDLES. This equipment is designed specifically for domestic purposes and Ariston cannot accept responsibility if used for any other type of application. This appliance conforms to the following EEC Directives: - 73/23/EEC and 93/68/EEC (Low Voltage Equipment) -89/336/EEC, 92/31/EEC and 93/68/EEC (Electromagnetic Compatibility) 2 1. General The appliance is designed for mounting at a safe level into an open housing which must be secured to the backing wall. 2. Oven Housing Cabinets . The oven unit housing cabinet dimensions must comply with Fig. 4 (see Installation Diagrams). . An air gap of 50 mm minimum must be provided at the rear of any top or bottom cupboards or shelves Fig. 1 (see Installation Diagrams). . Ventilation must be unobstructed, ie. from adjacent cabinetry. This can be done by either raising the base of the cabinets using the adjusting feet (or spacers) or alternatively by providing a slot in the cabinet plinth to the dimensions shown overleaf. . The air gap at the rear allows the warmed air to pass out of the inner cabinet space, but where it is intended to fit cupboards above the oven unit to ceiling height it is essential that the warmed air is exhausted through the front of the cabinet Fig. 1 (see Installation Diagrams). . If an oven unit is installed adjacent to a tall cabinet, steam escaping from the oven when the door is opened could condense on, and perhaps stain, the adjacent surface. To prevent permanent staining, the adjacent surface should be made of a material that is heat resistant and easy to clean. Adjacent tall cabinets should not be deeper than the oven housing cabinet. ! IMPORTANT, it is essential that the lower cupboard is constructed in the manner illustrated (see Installation Diagrams), ie. having side, back and roof panels so joined as to provide no apertures which could permit access to the oven unit when installed. 3. Final installation . Using a spirit level, check that the housing cabinet is level from side to side and from front to back in its installed position. . Correct any unevenness by placing wooden packing under the bottom of the cabinet. Make sure that the cabinet rests firmly on the cabinet floor without rocking . Before the oven is fitted, the cabinet must be firmly secured to the backing wall for stability. . The oven unit should now be lifted (by 2 adults) into the cabinet and pushed fully home. . Finally the oven unit must be secured to the cabinet by means of the four pozi wash head screws, two through each side trim. . Remove all packing material fr...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie