|
Facilità d'uso
Press these buttons with the tip of a blunt object (such as a ball point pen) whenever you change the batteries, or whenever performance is not behaving as expected (e.g., unable to establish radio frequency link with remote unit or automatic clock, etc.) This will return all settings to default value, and you will lose all stored information (minimum / maximum temperature and humidity, etc.). SAFETY AND CARE Wash the unit with a slightly damp cloth and mild detergent. Avoid dropping the unit or placing it in a location where the AC power adapter will be stepped on. 18 PS M01 English R17 op 18 7/24/03, 10:57 AM Black EN WARNINGS • Do not make any changes or modifications to This product is designed to give you years of service if this product. Unauthorized changes may void handled properly. Observe the following guidelines: your right to use the product. • The contents of this user manual are subject to • Never immerse the unit in water. This can change without notice. cause electrical shock and damage the unit. • Images not drawn to scale. • Do not subject the main unit to extreme force, shock, or fluctuations in temperature or humidity. • Do not tamper with the internal components. • Do not mix new and old batteries or batteries of different types. • Do not use rechargeable batteries with this product. • Remove the batteries if storing this product for a long period of time. • Do not scratch the LCD display. 19 PS M01 English R17 op 19 7/24/03, 10:57 AM Black EN Problem Symptom Remedy Temp Shows “LLL” or “HHH” Temperature is out-of- range. Calendar Strange date / month Change language ( 12) Backlight No continuous backlight Plug in AC power adapter. Check the BACKLIGHT switch. ( 8, 17) Cannot change channel Check sensors. Only one sensor is working ( 15 ) Problem Symptom Remedy 2. Press RESET. All memory items will return to default. Clock Cannot auto- synchronize 1. Remove batteries. 3. Replace batteries. Remote unit Cannot locate remote unit Check batteries ( 8) Check location ( 9) TROUBLESHOOTING Check here before contacting our customer service department. 20 PS M01 English R17 op 20 7/24/03, 10:57 AM Black EN Problem Symptom Remedy If it still fails, you may be too far from a signal. 4. Place clock near window / away from electrical devices, and wait 10 - 20 minutes. Cannot change clock Disable auto- synchronization ( 10) Baro Strange reading Set altitude / unit ( 14) SPECIFICATIONS Main unit dimensions L x W x H 129 x 43 x 133.3 mm (5.1 x 1.7 x 5.2 inches) Weight 457 grams with batteries Remote unit dimensions L x W x H 75 x 35 x 78.3 mm (3 x 1.4 x 3.1 inches) Weight 136 grams with battery Temperature Unit °C or °F Range Main unit: -5 .C to 50 .C (23 .F to 122 .F) Remote Unit: -20 °C to 60 °C (-4 °F to 140 °F) 21 PS M01 English R17 op 21 7/24/03, 10:57 AM Black EN Resolution Comfort Memory Trend Relative humidity Range Resolution Comfort Memory Trend 0.1 °C (0.2° F) 20 °C to 25 °C (68 °F to 77 °F) (see also, Relative humidity) Minimum / maximum +/- 0.5 °C (+/- 0.9 °F) change Main & Remote Unit: 25% to 95% 1% 40% to 70% (see also, Temperature) Minimum / maximum 3% change Barometer Unit Range Resolution Altitude Display Memory Trend Remote unit RF frequency Range Transmission 22 mb/hPa or inHg 500 to 1050 mb (14.77 to 31.01 inHg) 1mb (0.03 inHg) -100 to 2500 meters (-328 to 8202 feet) Rainy, cloudy, partly cloudy, sunny 24 hour 1mb change in 1 hour or 3mb change in 6 hours 433 MHz 30 meters (98 feet) with no obstructions approximately every 40 seconds PS M01 English R17 op 22 7/24/03, 10:57 AM Black EN Channel No. 1, 2, or 3 Unit °C or °F Radio-controlled clock Synchronization Auto or disabled Clock display HH:MM:SS Hour format 12hr AM/PM (MSF format) 24hr (DCF format) Calendar DD/MMM; weekday selection in 5 languages (E, D, F, I, S) Moon phase High, medium, and low tide Alarm 7 melody; 2 minute crescendo Snooze 8 minutes PS M01 English R17 op 23 Black Power Main unit 4 x UM-3 (AA) 1.5V alkaline batteries (back-up) AC/DC 6V power adapter (for normal operation and continuous backlight) Remote unit 2 x UM-4 (AAA) 1.5V alkaline batteries ADDITIONAL RESOURCES Visit our website (to learn more about your new product and other Oregon Scientific products such as digital cameras, hand-held organizers, health and fitness gear, and weather stations. The website also includes contact information for our customer service department, in case you need to reach us. 23 7/24/03, 10:57 AM EN Additional information: The product is therefore conform with the Low Voltage EC-DECLARATION OF CONFORMITY This product contains the approved transmitter module Directive 73/23/EC, the EMC Directive 89/336/EC and TX 07 and complies with the essential requirements of R&TTE Directive 1999/5/EC (appendix II) and carries the Article 3 of the R&TTE 1999/5/EC Directives, if used for respective CE marking. its intended use and that the following standard(s) has/have been applied: VS-Villingen / Germany August 2003...
Questo manuale è adatto anche per i modelli :Stazione Meteo - STARCK PS-M01 (203.81 kb)