|
Facilità d'uso
When a numerical value is displayed press this key to increase value of a parameter that is currently being modified. • Holding the b button down for approximately 3 seconds will speed up the rate at which the set point value increments. • In the Run Mode press b causes the display to flash the PEAK value – press again to return to the Run Mode. c (DOWN) • Press the down c button to go back to a previous Top Level Menu item. • Press this button twice to reset the controller to the Run Mode. • When a numerical value is flashing (except set point value) press c to scroll digits from left to right allowing the user to select the desired digit to modify. • When a setpoint value is displayed press c to decrease value of a setpoint that is currently being modified. Holding the c button down for approximately 3 seconds will speed up the rate at which the setpoint value is decremented. • In the Run Mode press c causes the display to flash the VALLEY value – press again to return to the Run Mode. d ENTER • Press the enter d button to access the submenus from a Top Level Menu item. • Press d to store a submenu selection or after entering a value — the display will flash a STRD message to confirm your selection. • To reset flashing Peak or Valley press d. • In the Run Mode, press d twice to enable Standby Mode with flashing STBY. Reset: Except for Alarms, modifying any settings of the menu configuration will reset the instrument prior to resuming Run Mode. 14 3.2 Menu Configuration It is required that you put the controller in the Standby Mode for any configuration change other than Setpoints & Alarms. Figure 3.1 Flow Chart for ID and Setpoints 15 3.2.1 ID Number SEE ID MENU SELECTION IN CONFIGURATION SECTION FOR ENABLE/DISABLE OR CHANGE ID CODE. If ID Code is Disabled or set as Default (0000) the menu will skip ID step to Setpoint Menu. If ID Code is set to Full Security Level and user attempts to enter the Main Menu, they will be prompted for an ID Code. If ID Code is set to Setpoint/ID Security Level and user attempts to enter the Configuration Menu, they will be prompted for an ID Code. ENTERING YOUR NON-DEFAULT FULL SECURITY ID NUMBER. Press a 1) Display shows ID. Press d 2) Display advances to ____. Press b & c 3) Press b to increase digit 0-9. Press c to activate next digit (flashing). Continue to use b and c to enter your 4-digit ID code. Press d 4) If the correct ID code is entered, the menu will advance to the Setpoint 1 Menu, otherwise an error message ERRo will be displayed and the instrument will return to the Run Mode. To change ID Code, see ID Menu in the Configuration section. ENTERING YOUR NON-DEFAULT SETPOINT/ID SECURITY ID NUMBER. Press a 5) Display shows SP1 Setpoint 1 Menu. Press a 6) Display shows SP2 Setpoint 2 Menu. Press a 7) Display shows ID ID Code Menu. Press d 8) Display advances to ____. Press b & c 9) Use b and c to change your ID Code. Press d 10) If correct ID Code is entered, the display will advance to the INPT Input Menu, otherwise the error message ERRo will be displayed and the controller will return to the Run Mode. To prevent unauthorized tampering with the setup parameters, the instrument provides protection by requiring the user to enter the ID Code before allowing access to subsequent menus. If the ID Code entered does not match the ID Code stored, the controller responds with an error message and access to subsequent menus will be denied. Use numbers that are easy for you to remember. If the ID Code is forgotten or lost, call customer service with your serial number to access and reset the default to 0000. 16 3.2.2 Set Points SETPOINT 1: Press a 1) Press a, if necessary until SP1 prompt appears. Press d 2) Display shows previous value of “Setpoint 1”. Press b & c 3) Press b and c to increase or decrease Setpoint 1 respectively. Holding b & c buttons down for approximately 3 seconds will speed up the rate at which the Setpoint value increments or decrements. Press b & c 4) Continue to use b and c to enter your 4-digit Setpoint 1 value. Press d 5) Display shows STRD stored message momentarily and then advances to SP2 only, if a change was made, otherwise press a to advance to SP2 Setpoint 2 Menu. SETPOINT 2: Press d 6) Display shows previous value of “Setpoint 2”. Press b & c 7) Press b and c to increase or decrease Setpoint 2 respectively. Holding b & c buttons down for approximately 3 seconds will speed up the rate at which the setpoint value increments or decrements. Press d 8) Display shows STRD stored message momentarily and then advances to CNFG only, if a change was made, otherwise press a to advance to CNFG Configuration Menu. 17 3.2.3 Configuration Menu Figure 3.2 Flow Chart for Configuration Menu Enter Configuration Menu: Press a 1) Press a, if necessary, until CNFG prompt appear. Press d 2) Display advances to INPT Input Menu. Press a 3) Pressing and releasing a to scroll through all available menus of Configuration section. 3.2.4 Input Type Menu Figure 3.3 Flow Cha...
Questo manuale è adatto anche per i modelli :Stazione Meteo - CNI8C (1.2 mb)
Stazione Meteo - CNI8DH (1.2 mb)
Stazione Meteo - CNI8DV (1.2 mb)
Stazione Meteo - CNI16 (1.2 mb)