Log:
valutazioni - 3, GPA: 3.3 ( )

Istruzioni per l'uso Hobart, Modello C54A ML-104198

Produttore : Hobart
File Size : 1.56 mb
File Nome :
Lingua di insegnamento:
Vai a scaricare



Facilità d'uso


It has a stainless steel tank and chamber with a welded stainless steel angle frame, stainless steel legs and stainless steel adjustable feet. Front inspection door(s) provide access to the interior of the wash/rinse chambers. CRS and CPW models also have a prewash inspection door. The C44A/AW, CRS66A/AW, CCS66A/AW, CPW80A/AW, C54A, CRS76A, CCS76A, CPW90A, C64A, CRS86A, CCS86A and CPW100A machines are capable of either high- or low-temperature operation. The C88A family is not available for low-temperature operation. Machines are available with steam, gas or electric heat. A Prewash Unit or Recirculating Scrapper are also available. Model C44A Right to Left Operation – 4 – STANDARD EQUIPMENT Controls (Fig. 1) STANDARD EQUIPMENT Controls (Fig. 1) Fig. 1 The controls are mounted on top of the chamber. There are three operational control switches housed in the control box: Power (ON-OFF); Motor (ON-OFF); and Timer (MANUAL-AUTO). A pilot circuit transformer provides a reduced voltage of 115 volts for the machine controls. When equipped for gas heat, a step-down transformer provides a reduced voltage of 24 volts for the igniter board(s) and valves. Motor and Pump Units The wash/rinse pump(s) are centrifugal-type cast stainless steel with a stainless steel impeller. The 2 HP motor is available in the following voltages: Volts Hz Phase Volts Hz Phase 208-240 60 1 380-415 50 3 208-240 60 3 380 60 3 200-240 50 3 480 60 3 60060 3 The conveyor drive motor is a 1/6 HP gear motor with the same voltage as the wash/rinse pump motor. A 1 HP prewash pump motor is standard on CRS and CCS models. A 2 HP prewash pump motor is standard on CPW models. Voltage and construction are the same as the wash/rinse pump motor. All motors have built-in thermal overload protection with manual reset. Vacuum Breakers The final rinse and fill lines contain an atmospheric vacuum breaker that prevents any reverse flow of water from the dishwasher into the potable water supply. Heater Protection A float-activated switch located in the wash tank (and rinse tank if included) automatically turns off the heat supply, if the water level is too low. Once the water returns to the proper level, the heating circuit becomes operational if heat is demanded. An overtemperature protector is also provided for electric and gas tank heat, and for built-in booster if provided. If overheating should occur, the heat supply will be turned off. Turn the Power switch OFF and contact your local Hobart service office. – 5 – Thermometers Thermometers Door Interlocks Door interlock switches will prevent machine operation while an inspection door is open. If a door is opened while the machine is operating, the pumps and conveyor will automatically turn off. Aft...

Questo manuale è adatto anche per i modelli :
Lavastoviglie - C44AW ML-104083 (1.56 mb)
Lavastoviglie - C44A ML-104047 (1.56 mb)
Lavastoviglie - C44A ML-104050 (1.56 mb)
Lavastoviglie - C44A ML-38898 (1.56 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie