Log:
valutazioni - 1, GPA: 4 ( )

Istruzioni per l'uso Kidde, Modello 1235CA

Produttore : Kidde
File Size : 574.71 kb
File Nome : 9544f1ed-c211-40c4-bd97-f42a4d65d744.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


• Plug the AC Quick-Connect wire harness into the back of the alarm (Image 5), making sure that the locks on the connector snap into place. Push the excess wire back into the electrical box through the hole in the center of the mounting plate. ATTACHING THE AC QUICKCONNECT WIRE HARNESS IMAGE 5 • Alignment marks are provided on the edge of the mounting plate and the alarm. After installing the mounting plate, place the alarm onto the mounting plate, making sure the alignment marks are lined up. Twist the alarm in the direction indicated by the “ON” arrow on the alarm cover (Image 4B) until it locks in place. I n s t a l l a t i o n Battery Backup Models 1275CA and PE120CA with battery backup will not function without a properly installed battery. They are equipped with a battery lockout feature which prevents the battery door from closing if a battery is not installed correctly. See Maintenance section for additional information concerning battery installation. Testing • To ensure proper operation of models 1275CA and PE120CA with battery backup, press the Test button (without the AC power connected). All interconnected, battery backed-up alarms, should respond. CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arms-length away from the unit when testing. • Tu rn on the AC power. The green LED power indicator should be lit when the alarm is operating from AC power. • For all models: C o n f i rm unit operation by pressing the Test button again. The smoke alarm is operating once AC power is applied, a f resh battery is installed (only for battery backup models 1275CA and PE120CA) and testing is complete. When the smoke alarm ionization sensor chamber senses products of combustion, the horn will sound a loud (85db) alarm until the sensing chamber is cleared of smoke particles. Alarm Tamper Resist Feature • To make the smoke alarm tamper-resistant, a locking pin has been provided in the bag with the screws and anchors. Using this pin will deter children and others from removing the alarm from the mounting plate. To use the pin, insert it into the hole in the side of the alarm after the alarm has been installed on the mounting plate (Image 4D). NOTE: The tamper-resistant pin will have to be removed in order to change the battery (models 1275CA and PE120CA). Use long nose pliers to pull the pin out of the hole. It is now possible to remove the alarm from the mounting plate. Operation Hush® Control Feature Model 1275CA only: Smoke alarms are designed to minimize nuisance alarms. Cigarette smoke will not normally set off the alarm, unless the smoke is blown directly into the alarm. Combustion particles from cooking may set off the alarm if the alarm is located close to the cooking area. Large quantities of combustible particles are generated from spills or when broiling. Using the fan on a range hood that vents to the outside (non-recirculating type) will also help remove these combustible particles from the kitchen. The Hush® button is extremely useful in a kitchen area or other areas prone to nuisance alarms. The Hush® feature has the capability of temporarily desensitizing the smoke alarm circuit for about 7 minutes. This feature is to be used only when a known alarm condition, such as smoke from cooking, activates the alarm. If the alarm does sound, check for fires first. If a fire is discovered, get out and call the fire department. If no fire is present, check to see if one of the reasons listed in Locations to Avoid may have caused the alarm. The smoke alarm is desensitized by pushing the Hush® button on the smoke alarm cover. If the smoke is not too dense, the alarm will silence immediately and “chirp” every 30-40 seconds for approximately 7 minutes. This indicates that the alarm is in a temporarily desensitized condition. The smoke alarm will automatically reset after approximately 7 minutes. If after this period particles of combustion are still present, the alarm will sound again. NOTE: Dense smoke will override the Hush® control feature and sound a continuous alarm. CAUTION: Before using the alarm Hush® feature, identify the source of the smoke and be certain a safe condition exists. O p e r a t i o n LED Indicators This alarm is equipped with red and green LED indicators: Red LED - Flashing eve ry 30-40 seconds: Indicates that the smoke alarm is operating pro p e r l y . Red LED - Flashing Rapidly: When the smoke alarm senses particles of combustion and goes into alarm (constant pulsating sound), the red LED will flash rapidly (one flash per second). The rapid flashing LED and pulsating alarm will continue until the air is cleared. When interconnected, only the red LED’s of the alarms that are sensing smoke or are being tested will flash rapidly (originating alarms). All other units in the interconnect system will sound an al...

Questo manuale è adatto anche per i modelli :
allarme antincendio - 1275CA (574.71 kb)
allarme antincendio - PE120CA (574.71 kb)
allarme antincendio - 1235CA (574.71 kb)
allarme antincendio - 1275CA (574.71 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie