Istruzioni per l'uso Greenheck Fan, Modello Combination Fire Smoke Damper SEFSDR-511

Produttore : Greenheck Fan
File Size : 100.95 kb
File Nome : 162dffcd-b831-4dfb-8a18-77122693db65.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


wg (1 kPa) UL 555S Leakage Rating Leakage Class: I Operational Rating: Actual ratings are actuator dependant Maximum Velocity: 3000 fpm (15.2 m/s) Maximum Pressure: 4 in. wg (1 kPa) Maximum Temperature: 350. F (177°C) —Depending on actuator Standard Construction Model SEFSDR-511 meets the requirements for fire dampers, smoke dampers and combination fire smoke dampers established by: National Fire Protection Association NFPA Standards 80, 90A, 92A, 92B 101 & 105 IBC International Building Codes New York City (MEA listing #260-91-M) California State Fire Marshall Listing #: 3225-0981:112 (fire) Listing #: 3230-0981:113 (smoke) “UL CLASSIFIED (see complete marking on product)” “UL CLASSIFIED to Canadian safety standards (see complete marking on product)” Standard 555 (Listing #R13317) Standard 555S (Listing #R13447) Frame/Sleeve: 20 ga. (1mm) 316 stainless steel integral sleeve Blade: Double skin 316 stainless steel (14 ga. [2mm] equivalent) round style blade Seal: Extruded silicone rubber blade seal Axle: 1/2 in. (13mm) dia. 316 stainless steel Bearing: 316 stainless steel sleeve type Fusible Link: UL listed 165.F (74.C) -not 316SS Size Limitations Minimum Size: 6 in. (152mm) diameter Maximum Size: 24 in. (610mm) diameter Optional Features • OCI (Open closed indication switches) -not 316SS • 165.F (74°C), 212.F (100°C), and 350.F (177°C) RRL -not 316SS. • TOR (remote override of 165. F (74°C) closure allows damper to perform smoke management functions during a fire emergency) -not 316SS. • Electric or pneumatic actuators to accomplish smoke management and system functions. • One retainer plate required, additional retainer plate available • 14 ga. (2mm) or 16 ga. (1.5mm) frame/sleeve Nut Opening + 2 in. Min. RetainingPlate Assembly Clamping Minimum Wall/Floor Opening Screw = Nominal Dia. + 7/8 in. Clamping Screw 1.00 in. Min. Typ. Installation instructions available at Fasteners D* * Dimensions furnished approximately 1/8 in. (3mm) undersize. 3.375 IN. FUSIBLE LINK (standard) LOCATION CLEARANCE FOR EXPANSION TOP VIEW OF DAMPER 6 IN. MAX SLEEVE LENGTH Wall DUCT CONNECTION AREA AIRFLOW 1.5 IN. ACTUATOR 16.00 IN MAX OPTIONAL BLADE POSITION INDICATOR AND/OR ELECTRIC LINK. 1.5 IN. 1.50 IN. Optional Second Retaining Plate Do not place retainer plate in this groove 5.375 in. 3.06 in. or 7.43 in.* * 7.43 in. when OCI, RRL, RRL/OCI, TOR, or PRV is selected Retaining plate 3.375 IN. FUSIBLE LINK (standard) LOCATION CLEARANCE FOR EXPANSION TOP VIEW OF DAMPER 6 IN. MAX SLEEVE LENGTH Wall DUCT CONNECTION AREA AIRFLOW 1.5 IN. ACTUATOR 16.00 IN MAX OPTIONAL BLADE POSITION INDICATOR AND/OR ELECTRIC LINK. 1.5 IN. 1.50 IN. Optional Second Retaining Plate Do not place retainer plate in this groove 5.375 in. 3.06 in. or 7.43 in.* * 7.43 in. when OCI, RRL, RRL/OCI, TOR, or PRV is selected Retaining plate Specifications True round combination fire smoke dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Dampers shall meet the requirements of the latest edition of NFPA 80, 90A, 92, 92A, 101 & 105. Damper shall be constructed of 20 ga. (1mm) 316 stainless steel frame; blades constructed of double skin 316 stainless steel round style blades; silicone rubber blade seals; . in. 316 stainless steel axles; 316 stainless steel bearings. Damper is provided with one retainer plate. Dampers shall be tested, rated and labeled in accordance with the latest edition of UL standards 555 and 555S. Dampers shall have a UL 555 fire damper of 1 1/2 hours. Each damper shall be equipped with a heat responsive device which has been tested and approved for use with the damper assembly in accordance with UL555. The heat responsive device shall have a temperature rating of (specifier select one of the following) 165. F (74.C), 212. F (100.C), 286. F (141.C) , or 350. F (177.C). Damper actuators shall be factory mounted and qualified for use with the damper in accordance with UL555S. Damper actuators shall be (specifier select one of the following) DUCT CONNECTION AREA electric type for 120 (or 24) volt operation or pneumatic type for 25 psi minimum (30 psi maximum) operation. Manufacturer’s submittal data shall indicate actuator space requirements around the damper. Dampers shall have a UL555S leakage rating of Class I and a temperature rating of 250.F (121°C) minimum. Dampers shall have a UL555S operational airflow equal to or greater than the airflow at its installed location and an operational pressure rating of 4 in. wg (1 kPa). All UL555 and UL555S dynamic closure ratings and leakage ratings shall be qualified for airflow and pressure in either direction through the damper. UL ratings shall allow for mounting damper vertically or horizontally. The Damper manufacturer’s submittal data shall certify all air performance pressure drop data is tested in accordance with the AMCA certified ratings program for test figures 5.2, 5.3, and 5.5. Damper air perform...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie