Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Firex, Modello SERIES 10000

Produttore : Firex
File Size : 188.86 kb
File Nome : 1101125CEnglish10000.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Specifications and Important Product Information . . . . . . . . . . . . . . . . . . . . . . . .1 Where to Install This CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 How ToInstall This CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 1. Installing an AC With Battery Back-Up Alarm . . . . . . . . . . . . . . . . . . . . . . . .3 2. Interconnecting AC Only and AC/DC Alarms . . . . . . . . . . . . . . . . . . . . . . . .3 If the Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Chart :Understanding the LED Lights and Horn Patterns . . . . . . . . . . . . . . .5 & 6 Troubleshooting the CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 & 6 Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Symptoms of CO Poisoning and sources of CO in the home Testing and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Service and Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 The following symbols identify the most important safety messages in this manual. When you see this symbol, be aware that if the DANGER message is ignored, the hazard WILL result in SEVERE bodily injury or death. When you see this symbol, be aware that if the message is ignored, the hazard CAN cause WARNING SEVERE bodily injury or death. When you see this symbol, be aware that if the message is ignored, the hazard CAN or WILL CAUTION cause MINOR bodily injury. About this Carbon Monoxide Alarm: This CO alarm is designed to detect carbon monoxide gas. It is NOT designed to detect smoke, fire, or any other type of gas. If this CO alarm sounds its alarm horn, DO NOT assume that it is a false alarm. The alarm horn requires your immediate action. WARNING Individuals with medical problems may consider using warning devices which provide audible and visual signals for carbon monoxide concentrations under 30ppm. SPECIFICATIONS AND IMPORTANT PRODUCT INFORMATION Product Features • Monthly Self-Test: Approximately every 30 days this alarm performs a silent internal system test to verify sensor operation utilizing True Gas Testing. True Gas Testing verifies that the CO sensor is nearing the end of its service life. Traditional CO alarms test the sensor by simulating an alarm condition electrically. This is the first CO sensor that runs a diagnostic test by generating a very small and harmless amount of hydrogen gas. If the sensor is working properly, it WILL NOT chirp. If the alarm chirps during the monthly self-testing, it is indicating a problem with the unit. Refer to the charts on pages 5 and 6 for the appropriate actions to take should this occur. You must still test the alarm weekly to verify proper horn operation. • Trigger Alarm Locator™ (TAL™): Most interconnect tests trigger all alarm horns simultaneously for the duration of the test. This unique system alternates between a 10 second ALL ON cycle and a 50 second cycle where only the initiating alarm is sounding. • Alarm Controlled Interconnect Test: In an interconnected system, this feature will alarm the local unit first, then quiet the local unit while the remote units alarm. • Smart Quiet™ Low Battery 1: Allows the homeowners to silence the low battery chirp for up to 10 hours, giving them time to go back to sleep and/or purchase a fresh replacement battery. • Smart Quiet™ Low Battery 2: Indicates the battery no longer has enough voltage to adequately protect in the event of a power outage or a battery-only installation. The Smart Quiet™ feature will no longer silence the chirp. THE BATTERY MUST BE REPLACED IMMEDIATELY. Required Power Supply (Series 10000 and 10400 only) • This CO alarm requires constant 120-volt, AC power AND/OR a working 9-volt battery to operate properly. This alarm WILL NOT work if AC power is not connected or has failed or been interrupted for any reason AND the battery is removed, drained or improperly connected. DO NOT use any other kind of battery except as specified in this manual. 1 NOTE: AC/DC alarms offer added protection in the event of a power failure or a drained battery. • DO NOT remove or disconnect the battery or turn off AC power to quiet unwanted alarms. This will remove your protection. This alarm features a Quick Quiet™ False Alarm Control button which, when activated, will quiet unwanted CO alarms for up to 6 minutes. Installation/Interconnect • This CO alarm should be installed only by a licensed qualified electrician. Observe and follow all local and national electrical and building codes for installation. • Unique power connector prevents interconnection with incompatible smoke and combination alarms or security systems. • This CO alarm may be int...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie