Log:
valutazioni - 2, GPA: 4.5 ( )

Istruzioni per l'uso First Alert, Modello SA100B

Produttore : First Alert
File Size : 197.15 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


by the required Smoke Alarms. For this reason, it is recommended that IMPORTANT! Read “Recommended Locations for Smoke Alarms” and 6. Check all connections. gauge or larger, rated at least 300V. If an interconnect wire is not 4. Hotels and Motels: Also boarding houses and dormitories. This “Locations to Avoid For Smoke Alarms” before beginning. This unit already part of your household wiring, you will need to install one. the householder consider the use of additional Smoke Alarms for those Smoke Alarm is suitable for use inside individual sleeping/resident areas for increased protection. The additional areas include the base- monitors the air, and when smoke reaches its sensing chamber, it This type of wire is commonly available at Hardware and Electrical rooms, provided a primary fire detection system already exists to meet LIMITED WARRANTY alarms. It can give you more time to escape before fire spreads. This Improper wiring of the power connector or the wiring leading to Supply stores. ment, bedrooms, dining room, furnace room, utility room, and hallways fire detection requirements in common areas like lobbies, hallways, or unit can ONLY give an early warning of developing fires if it is installed, the power connector will cause damage to the Alarm and may not protected by the required Smoke Alarms. The installation of Smoke BRK Brands, Inc., ("BRK") the maker of BRK® brand and First Alert® porches. Using this Smoke Alarm in common areas may not provide • All wiring must conform to all local electrical codes and Article 760 Alarms in kitchens, attics (finished or unfinished), or garages is not maintained and located where smoke can reach it, and where all resi-lead to a non-functioning Alarm. brand products, warrants that for a period of ten years from the date sufficient warning to all residents or meet local fire protection of the National Electrical Code (NFPA 70). Refer to NFPA 72 and/or normally recommended, as these locations occasionally experience dents can hear it, as described in this manual. This unit will not sense of purchase, this product will be free from defects in material and ordinances/regulations. STAND-ALONE ALARM ONLY: your local building code for further connection requirements. conditions that can result in improper operation. gas, heat, or flame. It cannot prevent or extinguish fires. workmanship. BRK, at its option, will repair or replace this product or • If you are only installing one Smoke Alarm, restore power A. Unswitched 120VAC 60 Hz source B. To additional units; Maximum = 18 total (Maximum 12 Smoke Alarms) 1. Smoke Alarm 2. Ceiling or Wall 4. Wire Nut 7. Interconnect Wire 3. Power Connector 5. Junction Box 6. Neutral Wire (Wht) 8. Hot Wire (Blk) any component of the product found to be defective during the warranty California State Fire Marshal (CSFM) Understand The Different Type of Smoke Alarms to the junction box. period. Replacement will be made with a new or remanufactured LIMITATIONS OF SMOKE ALARMS Early warning detection is best achieved by the installation of fire detec- Battery powered or electrical? Different Smoke Alarms provide product or component. If the product is no longer available, replacement tion equipment in all rooms and areas of the household as follows: A Smoke Alarms have played a key role in reducing deaths resulting from different types of protection. See “About Smoke Alarms” for details. INTERCONNECTED UNITS ONLY: may be made with a similar product of equal or greater value. This is Smoke Alarm installed in each separate sleeping area (in the vicinity, but home fires worldwide. However, like any warning device, Smoke Alarms Know Where To Install Your Smoke Alarms • If you are interconnecting multiple Smoke Alarms, repeat your exclusive warranty. outside bedrooms), and Heat or Smoke Alarms in the living rooms, dining can only work if they are properly located, installed, and maintained, and if Fire Safety Professionals recommend at least one Smoke Alarm on steps 1-6 for each Smoke Alarm in the series. When you smoke reaches them. They are not foolproof. This warranty is valid for the original retail purchaser from the date of rooms, bedrooms, kitchens, hallways, finished attics, furnace rooms, are finished, restore power to the junction box. every level of your home, in every bedroom, and in every bedroom initial retail purchase and is not transferable. Keep the original sales closets, utility and storage rooms, basements, and attached garages. Smoke alarms may not waken all individuals. Practice the escape plan hallway or separate sleeping area. See “Recommended Locations For at least twice a year, making sure that everyone is involved – from kids to Smoke Alarms” and “Locations To Avoid For Smoke Alarms” for details. receipt. Proof of purchase is required to obtain warranty performance. grandparents. Allow children to master fire escape planning and practice BRK dealers, service centers, or retail stores selling BRK products do ELECTRICAL SH...

Questo manuale è adatto anche per i modelli :
allarme antincendio - 100S (197.15 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie