Log:
valutazioni - 3, GPA: 4 ( )

Istruzioni per l'uso BRK electronic, Modello Carbon Monoxide Alarm C05120BN

Produttore : BRK electronic
File Size : 406.3 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


However, if the CO Alarm • This unit does not work without power. If the AC power fails, the (usually white) in the junction box. (OSHA) requirements for carbon monoxide detectors must be met. is installed outside the bedroom, it may not wake up a sound sleeper or one battery back-up will power the alarm for at least 7 days provided • Connect the black wire on the power connector to the hot wire (usually who has recently used drugs or has been drinking alcoholic beverages. This CO alarms may not waken all individuals. If children or others do not readily the 9V battery is fresh and correctly installed. black) in the junction box. is especially true if the door is closed or only partly open. Even persons who waken to the sound of the CO alarm, or if there are infants or family members with mobility limitations, make sure that someone is assigned to assist them • Connect the orange wire on the power connector to the interconnect are awake may not hear the alarm horn if the sound is blocked by distance or • The Silence Feature is for your convenience only and will not correct The Latching Alarm Indicator is activated after a CO Alarm is exposed to a CO problem. Always check your home for a potential problem after wire in the junction box. Repeat for each unit you are interconnecting. closed doors. Noise from traffic, stereo, radio, television, air conditioner, or in the event of an emergency. alarm levels of carbon monoxide. After CO levels drop below alarm levels, the any alarm. Failure to do so can result in injury or death. Never connect the hot or neutral wires in the junction box to the other appliances may also prevent alert persons from hearing the alarm horn. red LED will begin to flash once every 5 seconds. It will continue to flash or CO Alarms will not work without power. This CO Alarm requires a continuous orange interconnect wire. This CO Alarm is not intended for people who are hearing impaired. • This CO Alarm should receive continuous 120VAC, 60 Hz, pure sine “latch” until you clear it by testing the alarm. supply of AC power, and a fresh, correctly installed 9V battery to power the battery back-up. The battery back-up is for emergency use only! CO Alarms are not a substitute for a smoke alarm. Although fire is a source wave electrical power. (The battery is meant for emergency back- This feature helps emergency responders, investigators, or service technicians 3. Plug the power connector into the back of the CO Alarm. identify which unit(s) in your home were exposed to alarm levels of carbon CO Alarms for Solar or Wind Energy users and battery backup power of carbon monoxide, this CO Alarm does not sense smoke or fire. This CO up only). Do not use in an extension cord or outlet controlled by a Alarm senses CO that may be escaping unnoticed from malfunctioning dimmer or switch. In order for the emergency battery back-up to 4. Position the base of the Alarm over the mounting bracket and turn. The systems: AC powered CO Alarms should only be operated with true or pure monoxide. This can help investigators pinpoint the source of CO. furnaces, appliances, or other sources. Early warning of fire requires the work, a working (fresh) battery must be properly installed. Alarm can be positioned over the bracket every 60°. Turn the unit clockwise sine wave inverters. Operating this CO Alarm with most battery-powered UPS installation of smoke alarms. (right) until the unit is in place. series were exposed to alarm levels of carbon monoxide. CO Alarms are not a substitute for life insurance. Though these CO Alarms information on how to respond to an alarm. Failure to respond can Interconnected Alarms. Latching Alarm Indicator shows which Alarm(s) in the (uninterruptible power supply) products or square wave or “quasi sine wave” • NEVER ignore any alarm. See “If Your CO Alarm Sounds” for more inverters will damage the Alarm. If you are not sure about your inverter or 5. Check all connections. warn against increasing CO levels, BRK Brands, Inc. does not warrant or imply The Latching Alarm Indicator stays ON until you clear it, so it can alert you to UPS type, please consult with the manufacturer to verify. result in injury or death. A. Unswitched 120VAC B. To Additional Alarms, 60 Hz source Maximum = 18 Alarms 1. CO Alarm 4. Wire Nut 7. Interconnect Wire 2. Ceiling or Wall 3. Power Connector 5. Junction Box 6. Neutral Wire (White) (Orange) 8. Hot Wire (Black) in any way that they will protect lives from CO poisoning. Homeowners and a CO Alarm that occurred while you were away from home, even though CO In a Single-level Home: present in the air has dropped below alarm levels. This CO Alarm will not sense carbon monoxide that does not reach the • Test this Carbon Monoxide Alarm once a week. If it ever fails to renters must still insure their lives. sensor. This CO Alarm will only sense CO at the sensor. CO may be present test correctly, have it replaced immediately! If the CO Alarm is not • Install at least on...

Questo manuale è adatto anche per i modelli :
allarme antincendio - CO5120PDBN (406.3 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie