4. Press the control panel test button. Check the vibration pad is on and that the strobe is flashing. Daily & Weekly Testing We recommend that you test your system weekly by pressing all the smoke/heat alarm test buttons and checking that the vibration pad and strobe light are operating. Also check at the same time that the green power lights are visible on both the smoke alarm(s) and the control panel. Check daily that the vibration pad is in its correct position by pressing the test button on the control panel. Periodic Testing of Rechargeable Battery The rechargeable battery takes about 20 hours to charge from the control panel when it is first powered up. The panel then maintains it in the fully charged state by continuous trickle charge. In the event of a mains failure the battery will power the system in standby for a week followed by at least 4 minutes alarm. When the mains fails, the green light is extinguished and the red light flashes rapidly on the control panel to indicate it is on battery power. If the battery is starting to be fully depleted the red light will go off to indicate the control panel is totally unpowered. The battery will last 5 years in normal use provided it is not exposed to extremes of temperature for prolonged periods, or fully discharged/charged a large number of times. We recommend that the functioning of the rechargeable battery is checked at least yearly as follows: (i) Ensure the control panel has been mains powered for at least the previous 20 hours for the battery to charge. (ii) Turn off the mains power to the control panel by unplugging it or switching off the circuit at the distribution board. Check that the green light goes off and the red light starts to flash. (iii) Press the control panel test button for 20 seconds and check the strobe flashes brightly and that the pad vibrates strongly. Check that the red light continues to flash while the test button is pressed. (Cover the strobe light with a card to stop this dazzling you while looking for the red light). This red light flashing indicates that the battery is satisfactory. If the red light goes off, or if the strobe is weak, or if the vibration is weak, the battery will need to be replaced. Contact the nearest address in this leaflet for advice about getting a replacement. Replace Ei173 control panel after 5 years operation. (See date on side of panel). 3. Troubleshooting If the units fail any of the above tests after installation, the system has probably been incorrectly wired and/or all units are not connected. Check all wiring carefully. If the green power lights on the smoke alarm and/or the control panel are not on, check the wiring to the mains and that the mains is not off (e.g. due to a tripped circuit breaker or fuse). Check the power switch on the control panel is on. The control panel monitors the wiring to the vibration pad and the smoke alarm pattress for faults. (i) If the vibration pad is removed or if its wiring is open circuit, the...
Questo manuale è adatto anche per i modelli :allarme antincendio - Ei161 (125.25 kb)
allarme antincendio - Ei166 (125.25 kb)
allarme antincendio - Ei172 (125.25 kb)
allarme antincendio - Ei173 (125.25 kb)