Ordina : Nome ↑   Scaricare   Valutazione   Size ↑  
Scaricare : 5   File Size : 140 kb   Produttore : Bosch  
Categoria : allarme antincendio
@name

Because each manual station occupies only one address on the multiplex bus, it can be addressed for any point within the 9 to 255 range allowed by the multiplex expansion module. These manual stations are generally installed near building exits such as stairways and doors, allowing persons evacuating the building to activate the fire alarm. They have optional scored acrylic breakrods and a pull handle that locks in the activated position, to allow easy identification of alarm activation points.

Scaricare : 116   File Size : 1 mb   Produttore : Bosch  
Categoria : allarme antincendio
@name@name@name@name@name@name

Your PC must fulfill the following requirements: Hardware Description COM port Max. 4 (one COM port per panel) Interfaces USB/LPT Drives CD-ROM, 3.5" disk drive CPU min. 2 GHz RAM 1024 MB (server), 512 MB (client) Hard drive memory 10 GB Network card 100 Mbit Software Description Operating system Windows 2000 SP4, Windows 2003 server, Windows XP SP2 (not with Windows XP Home) Internet Explorer Version 5.5 SP1 or 6.0 MSDE Version MSDE 2000 SP3a Microsoft IIS Version 5.0 (Windows 2000, Windows XP)

Scaricare : 0   File Size : 100 kb   Produttore : Bosch  
Categoria : allarme antincendio
@name

When you press an incorrect key, a flat buzz tone sounds to indicate an invalid entry. 6. Faulted Point: When you enter an arming command, and a point is faulted, the sounder is activated for 2 seconds. The point status indicator associated with the faulted point is lit. 7. Watch Tone: When the Watch Mode is activated, the keypad emits a brief tone to alert you when any watch point is faulted and the point indicator lights to indicate which point is faulted. The tone sounds only when the door or

Scaricare : 7   File Size : 2 mb   Produttore : Bosch  
Categoria : allarme antincendio
@name@name@name@name@name@name@name@name@name@name@name@name@name@name

F.01U.088.879 | 3.0 | 2009.07 Bosch Sicherheitssysteme GmbH FAS-420-TM | FAS-420-TM-R | FAS-420-TM-RVB en 29 LSN Configuration Once the aspirating smoke detector has been connected to the LSN, the detector and detector unit are configured using the fire panel programming software via a laptop connected to the fire panel. Information on the LSN configuration can also be found in the Online Help of the programming software. Notes on diagnostics data for the fire panel are contained in the operatio

Scaricare : 0   File Size : 100 kb   Produttore : Bosch  
Categoria : allarme antincendio
@name

Ensure your security system is idle. 2. Press the [COMMAND] bar. The Command mode indicator light comes on. 3. Press the [5] key and then the [5] key again. Your security system is now in the Passcode Change Mode. 4. Enter the passcode you wish to change and press the [ENT] key. 5. Enter the new passcode and press the [ENT] key. 6. Enter the new passcode again and press the [ENT] key. 7. Test the new passcode by using it to arm and disarm the system. Do not use any of the keypad arming commands

Scaricare : 6   File Size : 100 kb   Produttore : Bosch  
Categoria : allarme antincendio
@name

Minimize fire hazards around the home. Smoking in bed, cleaning with flammable liquids such as gasoline, leaving children home alone, and unsafe holiday decorations are some of the more common causes of household fire. 2. Install a fire warning system. The primary purpose of this system is to protect lives, not property, by giving the earliest possible warning of the danger. In the event of a fire, the alarm system generates a loud intermittent tone distinctly different than a burglar alarm. In

Scaricare : 8   File Size : 2 mb   Produttore : Bosch  
Categoria : allarme antincendio
@name@name@name@name@name@name@name@name@name@name@name@name@name@name

Specific references are made to differences between the individual versions. 1. Insert the FAS-420-TM detection unit into the pre-mounted housing base that has been checked for correct wiring. 2. Change the X4 jumper position when inserting the detector unit (from PIN 1-2 to PIN 2-3, or vice versa). By doing so, the airflow is automatically calibrated (see Figure 5, Page 4). 3. The green operation display flashes when the FAS-420-TM is initializing. If initialization is complete, the operation d

Scaricare : 25   File Size : 378 kb   Produttore : Bosch  
Categoria : allarme antincendio
@name

Your Local Authority Having Jurisdiction (AHJ) should always be consulted before beginning the installation of any fire alarm system. 2.0 Glossary of Terms Beam Smoke Detector (Projected Beam Smoke Detector) A device which senses smoke or smoke and heat by projecting a light beam from a transmitter across the protected area to a receiver that monitors the light signal. Smoke and/or heat entering the beam path will decrease the light signal causing an alarm. Detector Coverage The area in which a

Scaricare : 136   File Size : 2 mb   Produttore : Bosch  
Categoria : allarme antincendio
@name@name@name@name@name@name@name@name@name@name@name@name@name@name

The default address is "0" (all DIP switches set to "off"). The DIP switch settings for all approved addresses are listed on pages 5-6 (0 = off, 1=on). Address (A) Operating mode Network structure Loop Stub T-tap 0 Automatic address assignment in "improved version" LSN mode X X - 1 to 254 Manual address assignment in "improved version" LSN mode X X X 255 = CL Automatic address assignment in "classic" LSN mode (address range: max. 127) X X - x = possible - = not possible i NOTICE! It is not permi