Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Kuppersbusch USA, Modello GMS 9551.0 E-UL

Produttore : Kuppersbusch USA
File Size : 377.65 kb
File Nome : GMS_9551.0_UandC_Guide.pdf

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


This appliance is easy to use. It is, however, important to thoroughly read the instructions in this handbook in order to obtain the best results. These instructions are only valid for the countries of destination, the identification symbols of which are indicated on the cover of the instruction manual and on the appliance itself. The manufacturer shall not be held responsible for any damages to persons or property caused by incorrect installation or use of the appliance. The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors; the designs in the figures are purely indicative. The Manufacturer also reserves the right to make any modifications to the products as may be considered necessary or useful, also in the interests of the user, without jeopardizing the main functional and safety features of the products themselves. COD. 04037ULKUP -25.06.2009 Kuppersbusch USA 1883 Massaro Blvd. Tampa, FL 33619 Toll: (800) 459-0844 P: 813-288-8890 F: 813-288-8604 MODELS: GMS 6540.0 E-UL -GMS 9551.0 E-UL DESCRIPTION OF HOBS TYPES: GMS 6540.0 E - ULTYPES: GMS 9551.0 E - UL 1 Ultra rapid gas burner 11000 Btu/h 2 Rapid gas burner 10000 Btu/h3 Semirapid gas burner 6100 Btu/h4 Semirapid gas burner 6100 Btu/h5 Auxiliary gas burner 3550 Btu/h6 Enamelled steel pan support 2F7 Enamelled steel pan support central8 Burner n° 1 control knob 9 Burner n° 2 control knob 10 Burner n° 3 control knob 11 Burner n° 4 control knob 12 Burner n° 5 control knob 13 Electric ignition button Attention: this appliance has been manufactured for domestic use only and it employment by private person. 2 SAFE GUARD INSTRUCTIONS 1) SAFE GUARD INSTRUCTIONS For all appliances: -the product shall be installed according with the a statement that the installation must conform with localcodes or, in absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. -The product must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. -The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure in excess of . psi (3.5 kPa). The maximun gas supply pressure is 4 inch WC and 11 inch WC and the gas pressure regulator provided is regulated to 1 inch water column above the manufacturer’s specified manihold pressure. -Always disconnect all cord connect appliances shall include instructions relative to location ot the wall receptacle and the warning to the user to disconnect the electrical supply before servicing the appliance. WARNING: If the information on this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. -Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or anyother appliance. -WHAT TO DO IF YOU SMELL GAS -Do not try to light any appliance. -Do not touch any electrical switch; do not use any phone in your building. -Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. -If you cannot reach your gas supplier, call the fire department. -Installation and service must be performed by a qualified installer; service agency or the gas supplier. -Save the orifices removed from the appliance for future use. -When a flexible service cord of the grounding type is provided to connect the appliance to a line-voltage electrical supply, the instructions shall also include the intent of the warning statement specified in 1.29.12. -The maximum depth cabinets installed above cooking tops be 13 in. (330 mm). -Keeping appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. -Not obstructing the flow combustion and ventilation air. 3 USE 2) BURNERS A diagram is screen-printed above each knob on the front panel. This diagram indicates to which burner the knob in question corresponds. After having opened the gas mains or gas bottle tap, light the burners as described below: -manualignition Push and turn the knob corresponding to the required burner in an anticlockwise direction until itreaches the full on position (large flame fig. 1), then place a lighted match near the burner. -Electricalignition Push and turn the knob corresponding to the required burner in an anticlockwise direction until itreaches the full on position (large flame fig. 1), then depress and release the ignition button “E”. -Automaticelectricalignition Push and turn the knob corresponding to the required burner in an anticlockwise direction until itreaches the full on position (large flame fig. 1), then depress the knob. -Lighting burners equipped with flame failure device The knobs of burners equipped with flame failure device must be turned in an anticlockwise direction until they reach the full on position (large flame fig. 1) and come to a stop. ...

Questo manuale è adatto anche per i modelli :
Altri elettrodomestici da cucina - GMS 6540.0 E-UL (377.65 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie