|
Facilità d'uso
1 (10/08) Page 3 of 4 5925 Heisley Road • Mentor, OH 44060-1833 OPERATING and MAINTENANCE INSTRUCTIONS for CCB-96A and CCB-120A Banquet Warming Cabinets TROUBLE-SHOOTING CHART: FAILURE POSSIBLE CAUSE 1. Yellow light at switch does NOT light. 1a. Circuit breaker/fuse to wall outlet blown. 2a. Cord is unplugged from wall outlet. 3a. Switch is “OFF.” 2. Unit does not get hot. 3. Unit gets too hot or won’t shut off 2a. Thermostat set too low or are off. 2b. Switch is “OFF.” 3a. Defective electrical parts. 3b. UNPLUG UNIT FROM WALL OUTLET 4. Blower does not work or makes noise. 5. Excess moisture in cabinet. 4a. Defective Blower 5a. Foods taken from oven or fryer should be “slacked out” for 5 minutes before placing in hot cabinet. NOTE: Optional digital thermometer will flash if cabinet temperature is below 140°F or above 250°F. Call the Factory if you need different settings. If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400. REPLACEMENT PARTS: DESCRIPTION Hot Unit Terminal Block Blower Kit Heater Kit Thermostat Kit Thermometer Kit Power Cord Switch Kit 120 VOLT HU18671-184* 0852-091 0769-180-K 0811-214-01 0848-062-K 5238-030-K 0810-029-02* 0808-118-K 240 VOLT HU18671-185 0852-091 0769-182-K 0811-215-01 0848-062-K 5238-030-K 0810-039-03 0808-118-K CABINET PARTS: DESCRIPTION Door Latch Kit Latch Strike Door Gasket, CCB-96A Door Gasket, CCB-120A Door Hinge Push Handle Wire Grid Door Assembly, CCB-96A Door Assembly, CCB-120A PART NO. 1006-143-K 1006-144-K 0861-173 0861-172 0519-084 1072-089 1170-095 1221-460-K 1221-461-K For Canadian Use:* Hot Unit (120 Volt) HU18671-184C Power Cord Plug 0713-017 Thermometer Kit, °C 5238-024-01 Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • Banquet Cabinets FL-2247 Rev. 1 (10/08) Page 4 of 4 5925 Heisley Road • Mentor, OH 44060-1833 OPERATING and MAINTENANCE INSTRUCTIONS for CCB-96A and CCB-120A Banquet Warming Cabinets 5-15P 120V, 15A HEATER ELECTRICAL SPECS HOT UNIT #0671-184 1650W, 120V, 60Hz, 1 Ph BLOWER AC SERVICE GREEN 7 8 1 3 3 13 12 SLEEVING 13 12 BLOCK TERMINAL G W BROWN 1 2 G 7 2 BLUE 11 HEATER 10118 9 9 10 BLOWER THERMOSTAT POWER PILOT SWITCH LIGHT DIAGRAM FOR 120V UNITS 6-15P 240V, 15A G GREEN 8 2 8 7 3 1 4 3 13 7 4 12 11 TERMINAL BLOCK W G BROWN 1 2 BLUE109 13 12 HEATER 9 11 10 SLEEVING BLOWER HEATER HOT UNIT #0671-185 1650W, 240V, 60Hz, 1 Ph AC SERVICE BLOWER THERMOSTAT POWER PILOT SWITCH LIGHT DIAGRAM FOR 240V UNITS Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • ...
Questo manuale è adatto anche per i modelli :Altri elettrodomestici da cucina - Banquet Warming Cabinets CCB-96A (507.53 kb)