|
Facilità d'uso
SAFETY AND WARNINGS WARNING! Electrical shock hazard Disconnect product from main power supply before installing appliance. Failure to do so may result in electrical shock or death WARNING! Cut hazard Take care - panel edges are sharp. Failure to use caution could result in injury or cuts. WARNING! Tipping hazard Do not operate this apppliance until it has been securely anchored inside the cabinetry. The cabinet must be securely anchored to the floor. Failure to use caution could result in injury or cuts. Important safety precautions! Installation of the CoolDrawer requires competent mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the CoolDrawer installation, the Installer must perform the Final Check List. Remove all packaging materials supplied with the CoolDrawer. The CoolDrawer is manufactured for indoor use only. The CoolDrawer MUST be installed to allow for future removal from the enclosure if service is required. Do not seal the CoolDrawer into the cabinetry with silicone or glue. Doing so will make future servicing difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-in product, nor for repairing any damage that may be incurred by doing this. Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord. Failure to install the CoolDrawer correctly will invalidate any warranty or liability claims. If the power supply cord is damaged, it must be replaced. Parts are available from your Authorised Fisher & Paykel dealer. Cabinetry must be sufficiently robust to support a combined product and food load of 220 lb (100 kg). Bearers may be required to support the internal shelf. Before you install the CoolDrawer, please make sure that The switched power outlet must be outside the refrigerator drawer cavity so that it is accessible after installation. The switched power outlet must be located outside the cavity, within 55” (1400 mm) from the CoolDrawer cavity if situated on the left-hand side of the cavity and within 33” (840 mm) if situated on the right-hand side of the cavity. The services hole in the refrigerator cavity needs to be large enough for the power supply plug to fit through. 2 PRODUCT DIMENSIONS 3 CABINETRY DIMENSIONS Installation diagrams for illustration purposes only E Installation diagrams for illustration purposes only G F F C D H G A B An internal shelf can be used as an alternative to spacer blocks to position the product at the correct height. In this case additional cutouts will be required. Refer to Step 7. A BC D Product dimensions (inches [mm]) CoolDrawer RB36SRB90S Cabinetry dimensions (inches [mm]) CoolDrawer RB36SRB90S A overall width of cabinetry frame 36” (914) A overall height of product (inc. installation brackets) 25 /” (640) B overall width of product 33 /” (855) overall depth of product (excl. drawer panel; inc. power cord) 21 /” (557) D depth of drawer (open) (excl. handle) 20 .” (520) B minimum inside width of cabinetry frame 34” (864) C height from frame inner face to top of spacer block 25 /” (644) D height below top of spacer block to frame inner* (to allow for outlet duct height) max. 4 /” (120) min. /” (21) E minimum height of toe kick 3” (75) F minimum depth** of toe kick 1 /” (40) G minimum distance from front of cabinetry to rear wall 22 /” (560) H width of spacer blocks 1 /” (50) *Minimum internal height of cabinetry frame can be 25 /” (644mm) if outlet duct is not used. **All depth measurements are taken from the front face of the cabinetry frame (not drawer panel) Minimum clearances (inches [mm]) /” (2 mm) .” (13 mm) 4 PARTS SUPPLIED Installation brackets Phillips 16 mm Trim brackets (4) Pan Head Installation Power Outlet duct (1) Pan Head Drawer Panel Phillips (left-hand and right( /” ) wood 16 mm (/” ) trims (2) cord (1) 16 mm (/” ) attachment 16 mm hand side) (2) screw (6) screw (12) screw (2) hooks (3) (/” ) wood screws (6) 5 CAVITY PREPARATION Important! Disconnect power to surrounding appliances before preparing cavity. Recommended to allow the vertical removal of the refrigerator bins. max. .” (20 mm) max. 33” (840 mm) min. o 1 /” (50 mm) BenchtopPanelmin. 21” (535 mm) min. 5” (130 mm) Note: Services can be located either side of CoolDrawer. min. 21” (535 mm) min. 5” (130 mm) Shows cutout if cabinetry depth at 21 /” (550 mm) Integrated Panel material Maximum weight of 15.5 lb (7 kg). Height of Drawer Panel Dimension A Reveal dimension B Height between top of spacer block and underside of benchtop C D Drawer panel height To calculate D complete the following equation: D = B - A - C i.e. For the F&P prefinished panel with a .“ (6 mm) reveal: 18 .” (476 mm) Height of the False Panel F&P prefinish panel width is 35 .” (896 mm) F&P prefinish panel height (D) is 18 .” (476 mm) Installation diagrams for illu...
Questo manuale è adatto anche per i modelli :Altri elettrodomestici da cucina - IZONA RB905 (2.03 mb)