|
Istruzioni per l'uso Garland, Modello E22-36
Produttore : Garland File Size : 151.81 kb File Nome : 55958d63-6988-49d3-885b-229698e6466a.pdf
Lingua di insegnamento:
|
|
|
|
Vai a scaricare
Facilità d'uso
READ THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT. INSTALLATION AND OPERATING INSTRUCTIONS FOR THE GARLAND ELECTRIC TEPPENYAKI GRIDDLE MODEL E22-36 PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE. THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE INSTALLED BY PROFESSIONAL PERSONNEL AS SPECIFIED. INSTALLATION AND ELECTRICAL CONNECTION MUST COMPLY WITH CURRENT CODES: IN CANADA - THE CANADIAN ELECTRICAL CODE PART 1 AND / OR LOCAL CODES. IN USA – THE NATIONAL ELECTRICAL CODE ANSI / NFPA – CURRENT EDITION. ENSURE ELECTRICAL SUPPLY CONFORMS WITH ELECTRICAL CHARACTARISTICS SHOWN ON THE RATING PLATE. ® Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified or repaired using unauthorized parts or by unauthorized service agents. For a list of authorized service agents, please refer to the Garland web site at The information contained herein, (including design and parts specifications), may be superseded and is subject to change without notice. Continuous product improvement is a Garland policy, therefore design and specifications are subject to change without notice. Garland Commercial Industries, Inc. Garland Commercial Ranges Ltd Enodis UK LTD 185 East South Street 1177 Kamato Road, Mississauga, Ontario Swallowfield Way, Hayes, Middlesex Freeland, Pennsylvania 18224 L4W 1X4 CANADA UB3 1DQ ENGLAND Phone: (570) 636-1000 Phone: 905-624-0260 Telephone: 081-561-0433 Fax: (570) 636-3903 Fax: 905-624-5669 Fax: 081-848-0041 Part # 4517056 (10/04) © 2004 Garland Commercial Industries, Inc. GENERAL INFORMATION 1. Check the crate for possible damage sustained during transit. Carefully remove the unit from the crate and again check for damage. Any damage to the appliance must be reported to the carrier immediately. 2. The type of voltage supply that the equipment was manufactured for at the factory is noted on the data plate on the equipment. This type of supply must be used. 3. Do not remove permanently affixed labels, warning or data plates form the appliance, this may void approvals and create a safety hazard. The Garland E22 series complies with the standards CSA C22.2 no. 109 – latest edition and UL197 – latest edition. The installation and connection of this appliance must comply with current codes. In Canada – the Canadian Electrical Code Part 1 and in the USA – the National Electrical Code. SAFETY • A qualified person must make the installation in accordance with the authority having jurisdiction and local codes. • This unit must only be operated by a qualified person. DO NOT operate without reading this manual. • DO NOT operate this appliance unless all service and access panels are in place and fastened properly. • DO NOT attempt to repair or replace any part of this appliance unless all main power supplies have been disconnected. • DO NOT clean this appliance unless the power supply is disconnected. WARNING: To avoid serious personal injury: • USE EXTREME CAUTION in setting up, operating and cleaning these appliances to avoid coming in contact with hot surfaces. Wear suitable protective clothing or use proper utensils to prevent the risk of burns. NOTE: All warning labels and markings on this appliance, which call attention to further dangers and necessary precautions. SPECIFICATIONS Models:E22-36-36GM(X)E22-36-45GM(X)E22-36-48GM(X)E22-36-56GM(X) E22-36-60GM(X)E22-36-68GM(X)E22-36-72GM(X) X suffix use electronic thermostatsTotal kW LoadingkW Loading Per PhaseNominal Amps Per PhaseSingle PhaseThree Phase240V208V240V208V240V208V240V208VX-YY-ZX-ZX-YY-ZX-ZXYZXYZ6.76.73.35---3.353.35---3.3527.9232.2124.2213.9613.9627.9516.1116.11 The E22-36-36GM(X) is for installation in non-combustible locations only. All others should be installed with the following minimum clearances from combustible material. Minimum Installation Clearances Left & Right Sides Rear Type of Floor Base 1/2” (12.5mm) 1/2” (12.5mm) Combustible Page 2 Part # 4517056 (10/04) INSTALLATION Electrical Supply: Before attempting the electrical connection, the rating plate should be checked to ensure the equipment’s electrical characteristics and the supply electrical characteristics agree. On griddles the supply entrance is located at the rear or alternatively on the main bottom. The supply terminal block is accessible from the front. The electrical supply must be adequate for the voltage, phase and current marked on the rating plate. Note: A means of disconnection from the supply having a contact ...
Scrivi la tua opinione del dispositivo
|
|