Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso Pentair, Modello Illuminator PG2000

Produttore : Pentair
File Size : 204.3 kb
File Nome : 3114fdb5-40f0-b664-5d6b-f53af9fe694b.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400 Visit us on the Internet at: or Rev. C 7-29-05 1 P/N 840263 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS BEFORE OPERATING SYSTEM Operating the PG2000 Refer to the toggle switch position diagram below for the appropriate switch positions for your particular installation. The switches are located on the lower right side of the unit. The PG2000 should always operate in manual mode no matter what type of control system is installed. NOTE When cycling system off, then back on, it may take up to 3-4 minutes before the lamp "restrikes" or comes back on. The lamp must cool down before restriking. All metal halide lamps have this characteristic and this is a normal function of the PG2000. WARNING Bulb socket, and reflector are extremely hot during and following operation. Allow sufficient time for cooling before touching them, or you may suffer severe burns. CAUTION Do not touch the bulb with your bare fingers - fingerprints can actually cause the bulb to overheat and crack. Handle the bulb using sheath provided in packaging. COLORPOWER RF2000 WIRELESS CONTROL COLORPOWER REMOTE SWITCH CONTROL COLOR ON POWER ON MANUAL CONTROL TOGGLE SWITCH POSITIONS COLOR OFF POWER OFF Figure 1. RemoveScrewsIntakeVents CAUTION PG2000 Illuminator must have good ventilation to operate properly. Blockage of air flow or air intake will shorten the bulb life and could damage the unit. Make sure foliage; grass, groundcover, yard debris, etc. is kept clear of intake vents on back of the unit in order to allow for proper air flow. Do not install PG2000 Illuminator in an underground utility box or similar appliance. Damage to the unit due to blocked air vents or poor ventilation will void the warranty. Replacing the Bulb. 1. Turn power to unit off. WARNING Turn off power before changing bulb. Failure to turn off power may lead to severe electrical shock, which can result in death or severe injury. 2. Remove two screws securing outer body and lift outer body straight up. 3. Remove screws (3) at bottom of socket bracket, (see Figure 1.) and separate socket bracket assembly from reflector. Remove bulb from socket and insert new bulb. Be sure not to touch the glass of the bulb. 4. Reassemble socket bracket and make sure bulb is centered in reflector. 5. Replace outer body and secure with two screws. P/N 840263 2 Rev. C 7-29-05 PG2000® Synchronization Procedures with SAm® light Listed below are the procedures to follow if you have a SAm underwater color light installed in your pool or spa and wish to synchronize your fiber optics with SAm. NOTE There may be slight color variations between the SAm and PG2000 depending on the application. These variations are caused by differences in initial light intensity and attenuation of the water and/or reflective surfaces (i.e. pool wall coloring). In order for instructions to work you must have P/N 840242 – 7 Color, Electronic Synchronized PG2000 (all other part numbers must use visual synchronization method) Synchronization Start Conditions 1. SAm is ON and colorwheel is stopped on ANY color (including white). 2. PG2000 power is ON and the colorwheel is OFF. Synchronization Procedure 1. Simultaneously toggle SAm OFF/ON and turn the PG2000 colorwheel ON. 2. Allow about 1. minutes for colors to synchronize. Enjoy! 3. To stop both lights on the same color, simultaneously toggle SAm OFF/ON and turn the PG2000 colorwheel OFF. Visual Synchronization Method (for use with P/N 840241 only) 1. Turn SAm ON, colorwheel is stopped on ANY color (including white). 2. Turn PG2000 ON and colorwheel ON. 3. When PG2000 transitions between purple and magenta toggle SAm OFF/ON. 4. To stop both lights on the same color, simultaneously toggle SAm off and on while turning the PG2000 colorwheel off. Troubleshooting If the PG2000 does not come on at all… • Make sure the power switch is on (see switch position diagram). On Auto Remote Control (Compool®/Jandy®) make sure the proper auxiliary is turned on. The PG2000 should always operate in manual mode no matter what type of control system is installed. • Check that the circuit breaker is not tripped. • Check the incoming voltage at the PG2000 to verify power supply. • Check the fuse(es) inside the unit. Replace if fuse is open. If there is no light… • Check that the bulb is in place securely in the socket. • If you can hear the fan running the lamp has probably failed. Replace lamp. If the fan runs, but the light cycles on and off… • Check the vents of obstructions. There must be adequate air flow or PG2000 will overheat and begin to cycle. • If the unit is operating in direct sunlight during a very hot day it may exceed the recommended operating temperature and cycle on and off. This protects the end of the fiber optic cables from damage and is normal. If the light comes on, but the fan is not running… • Turn...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie