Turn LP gas tank “ON” at valve. Spoon leak check solution at all “x” locations If any bubbles appear turn LP gas tank “OFF”, reconnect and re-test. If you continue to see bubbles after several attempts, disconnect LP gas source and contact 1.800.762.1142 for assistance. If no bubbles appear after one minute turn tank “OFF”, wipe away solution and proceed. Placement Properly positioning your SkeeterVac® device is important to maximizing performance. Since the SkeeterVac® device attracts mosquitoes it should be placed at least 10 feet from your living areas. Mosquitoes typically live in areas that are shady, wet and/or moist. Determine the primary mosquito habitat and place your SkeeterVac® device as close as possible to it. If you live in an area with consistent wind, place your SkeeterVac® device upwind from the primary mosquito habitat. Maximum performance may require relocating your SkeeterVac® device from time to time. To move, place your foot on the cart base and tilt backward by holding the handle. Pull to the new location. X X X X X LP Gas Tank Valve Regulator/Hose Assembly Connection Lure Output: Fully Open FineTune®: Customizing the Lure Output The amount of octenol your SkeeterVac® device dispenses is important to maximizing performance. Some mosquito species are highly attracted to octenol while others are less attracted. This product contains an easy-to-use feature that allows you to customize the amount of octenol released to match the species in your environment. Note: Lure lasts 60 days. 1. Remove Finetune® cover by turning counterclockwise. 2. Remove foil seal from the Finetune® Lure. 3. Place Finetune® lure back into holder with holes orienting upward. 4. Replace Finetune® cover. 5. Select the lure output by adjusting the Finetune® cover. Lure Output: Half Open Lighting CAUTION: Do not operate with WaveDrawer® cover on the WaveDrawer® 1. Read instructions before lighting. 2. Turn “ON” gas at LP gas tank. 3. Press and hold control valve button. 4. IMMEDIATELY press and hold igniter button down until you hear a “POP” sound indicating ignition. Normally occurs within 20 seconds. 5. Continue to hold control valve button for 30 seconds. 6. The needle on the engine gauge should begin to move into the “Green” zone, the LED lights will be flickering and the vacuum fan will be running with air flow out of the engine bottom, indicating ignition is complete. CAUTION: If engine fails to light, shut LP gas off at tank and wait 5 minutes before attempting to restart the engine by following the lighting instructions. Button Placement Igniter Button Control ValvButton Battery Lure Output: Closed e Turning Off Turn LP gas tank “OFF” by turning valve clockwise until it stops. CAUTION: The gas supply must be turned off at the LP-gas tank when this outdoor gas appliance is not in use. Outdoor LP Gas Mosquito Exterminator Model No. SV3100 Cleaning and Care CAUTION: All cleaning and maintenance should be done when SkeeterVac® is cool and with the fuel supply disconnected. CAUTION: DO NOT clean any SkeeterVac® part in a self cleaning oven. CAUTION: This SkeeterVac® should be thoroughly cleaned and inspected on a regular basis. CAUTION: Abrasive cleaners will damage this product. Before Each Use: 1. Keep the SkeeterVac® area clean and free from any combustible materials, gasoline, and other flammable vapors and liquids. 2. Do not obstruct the flow of the combustion of LP and the ventilation air. 3. Keep the ventilation opening(s) of the LP gas tank area free and clear from debris. 4. See “Cleaning Instructions” for proper cleaning LP Gas Tank Ventilation Area instructions. Cleaning Instructions / Routine Service To ensure maximum performance and to lengthen the life of your SkeeterVac® device, perform these steps each time your tank is empty. This model will consume a standard 20# LP gas tank every 18-21 days. Note: While unit is in use, check the following every 2-3 days: • Check WaveDrawer® and clean (if necessary). • Check air passages for blockage. 1. Turn LP gas tank valve “OFF”. 2. Disconnect hose/regulator gas line from tank by turning knob counterclockwise. 3. Remove empty tank replace with full LP gas tank. 4. Slide WaveDrawer® cover onto WaveDrawer®. 5. Remove WaveDrawer®, empty and clean. 6. Slide WaveDrawer® back into place. 7. Remove WaveDrawer® cover. 8. Remove used TacTrap™ and dispose of properly. 9. Slide fresh TacTrap™ in place and remove protective paper. 10. Remove Finetune® cover by turning counterclockwise. 11. Remove used Finetune® lure (if necessary) and properly dispose. Note: Finetune® Lure lasts 60 days. 12. Remove fresh Finetune® lure from package (if necessary). Dispose of packaging properly. 13. Place Finetune® lure back into holder with holes orienting upward. 14. Replace Finetune® cover. 15. Select the lure output by adjusting the Finetune® cover. 16. Check engine and gas lines for any sign of damage or missing parts. Repair any problems before attempting to start. 17. Reconnect gas ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie