Log:
valutazioni - 2, GPA: 3.5 ( )

Istruzioni per l'uso Axor, Modello 6024EZ

Produttore : Axor
File Size : 1.13 mb
File Nome : ac437cef-1d8d-49d6-8a4e-bd283e30e25a.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Helpful tips for removing your current drain can be found in the Troubleshooting section of these instructions. To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin. 1.1 Recommended tools Screwdriver Channel Locks ‘3^= Adjustable Wrench Tubing Cutter INSTALL FAUCET CAUTION Turn off hot and cold water supplies before beginning. Turn off hot and cold water supplies before beginning. Insert FAUCET (1) and CABLE CONNECTOR (2) through mounting holes of Sink or mounting surface. Fig. A. Assemble LOCKNUTS (3) onto SHANKS (4) (from under side of Sink. Hand tighten firmly. Fig. B. (HAND TIGHTEN) INSTALL POP-UP DRAIN ■ Remove CLEAR PLASTIC COVER (1). Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3). Fig. A. ■ Drop DRAIN BODY (4) through sink drain hole. Make sure WHITE FOAM GASKET (5) is under flange of DRAIN BODY (4). Fig. B. Note: No plumber's putty or caulk is required. ■ The CABLE ATTACHMENT POINT (6) must face towards the rear of the SINK. Fig. B. CJ INSTALL BLACK GASKET ■ Install BLACK CONE GASKET (1) onto DRAIN BODY (2) from below. Note: The flat side of the BLACK CONE GASKET (1J must face down. INSTALL GRAY LOCKNUT ■ Install GRAY LOCKNUT (1) onto DRAIN BODY (2) from below SINK. Fig. A. Note: The flat side of the GRAY LOCKNUT (1) must face up. ■ Tighten firmly by hand. No tools are required. Check DRAIN FLANGE in SINKto ensure that WHITE FOAM GASKET (3) is fully compressed and not visible. Fig. B. POP-UP KNOB POP-UP KNOB (1J must be fully down. M968914 Rev. 1.1 2 ATTACH CABLE CONNECTOR Thread CABLE CONNECTOR (1J clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig. A. Your new POP-UP DRAIN installation is now complete. Fig. B. Note: Tailpeiceon pop-up drain is 1-1/4" O.D. Fig. B. CHECK OPERATION OF POP-UP ■ Operate LIFT KNOB (1 ) to verify that STOPPER (2) opens and closes. Fig. B. Note: If STOPPER (2) does not open and close properly then refer to the "troubleshooting section" of these instructions. MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE: FLEXIBLE SUPPLIES OR BULL-IMOSE RISERS MUST BE PURCHASED SEPARATELY. Connect water supply to FAUCET (1J with 1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length. Connect 1-1/4"O.D.tailpiece on POP-UP DRAIN to waste outlet. M968914 Rev. 1.1 3 TEST INSTALLED FITTING With HANDLES (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks. ^ Remove AERATOR (3). Operate both HANDLES (1 ) to flush water lines thoroughly. Replace AERATOR (3). CHECK DRAIN CONNECTIONS Operate POP-UP KNOB f4) and fill lavatory with water. Check that DRAIN STOPPER (5) makes a good seal and retains water in SINK. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions. Release POP-UP KNOB (5) down and check all drain connections and "P" trap for leaks. ^Tighten if necessary. 10 SERVICE To change direction of handle rotation, proceed as follows: To change direction of handle rotation, proceed as follows: ■ Turn valve to OFF position. ■ Remove INDEX BUTTON [1] and HANDLE SCREW (2). ■ Pull HANDLE (3) with ADAPTER (4) off. ■ Remove SPRING CLIP (5). ■ Lift STOP WASHER (6), turn 90" and replace. ■ Replace SPRING CLIP (5). ■ Replace ADAPTER [4), HANDLE (3), SCREW (2) and INDEX BUTTON [1]. AERATOR (7) may accumulate dirt causing distorted and reduced water flow. Remove AERATOR (7J and rinse clean. If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90”. EverClean™ Finish Care Instructions American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. No additional cleaning products are required. DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface. M968914 Rev. 1.1 11 4 Speed Connect™ Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the “down” position: • Follow CABLE ADJUSTMENT PROCEDURE. If Stopper does not raise up fully or sink drains too slowly: • Follow CABLE ADJUSTMENT PROCEDURE. If you need to remove the Stopper: • Follow STOPPER REMOVAL PROCEDURE. If you would like the ability to remove your Stopper simply by lifting it out of the drain: • Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode. CABLE ADJUSTMENT PROCEDURE ■ Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A. ■ Look at the area on the Drain Body where the Cable was attached and locate the component labeled as "Cam" in the illustration. Fig. B. ■ Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the Stopper should be in the UP positio...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie