|
Facilità d'uso
If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. Thermopile THTP TH TP Limit Switch BK BK BK WHT* NOTES: LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted with a piezo ignitor. When lighting the pilot, follow these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Extinguish any open flame. • Open windows. • Do not light any appliance. • Do not touch any electrical switches. TO TURN OFF GAS TO APPLIANCE 1. Turn remote wall switch “OFF.” The pilot will remain lit for normal service. 2. For complete shutdown, turn remote wall switch to “OFF.” 3. Access the lower control compartment. 4. Depress gas control knob slightly and turn clockwise to “OFF.” Do not force. 5. Close lower control compartment. LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this page. 2. Access the lower control compartment. 3. Turn remote wall switch to “OFF.” 4. Verify main line shut-off valve is open. 5. Push in gas control knob slightly and turn clockwise to “OFF.” 6. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step. 7. Push in gas control knob slightly and turn counterclockwise to “PILOT.” 8. Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark ignitor (pushing the button) until pilot lights. Continue to hold the control knob in for about 1 ... minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8. • If knob does not pop up when released, stop and immediately call your service technician or gas supplier. • If pilot will not stay lit after several tries, turn the control knob to “OFF” and call your service technician or gas supplier. 9. Turn gas control knob counterclockwise to “ON.” 10. Close lower control compartment. • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. • If your gas supplier cannot be reached, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Note:Knob cannot be turned from“PILOT”to“OFF” unless the knob is pushed in slightly. Do not force. HONEYWELL MILLIVOLT GAS VALVE SIT MILLIVOLT GAS VALVE ON OFF PILOT HI LOW TPTH TP TH PILOT PILOTON it OFF OUTIN SIT MILLIVOLT PILOT INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de reglage jusqu’au fond et gardez-le enfonce. Allumez immediatement la veilleuse en declenchant l’allume-gaz a etincelle (en poussant le bouton) jusqu’a ce que la veilleuse s’enflamme. Continuez de tenir le bouton de reglage enfonce pendant environ 90 secondes apres l’allumage de la veilleuse. Relachez le bouton et il sortira subitement. La veilleuse devrait rester allumee. Si elle s’eteint, repetez les etapes 5 a 8 inclusivement. • Si le bouton ne sort pas automatiquement apres avoir ete relache, arretez immediatement et telephonez a votre technicien de service ou a votre fournisseur de gaz. • Si la veilleuse refuse de rester allumee apres plusieurs tentatives, tournez le bouton de reglage jusqu’a sa position d’arret “OFF” et telephonez a votre technicien de service ou a votre fournisseur de gaz. 9. Tournez le bouton de reglage du gaz en sens inverse des aiguilles d’une montre jusqu’a sa position de marche “ON”. 10. Fermez le compartiment de controle du bas. 11. Au besoin, rebrancher l’appareil au courant electrique et remettre l’interrupteur du bruleur principal a la position “ON” ou regler le thermostat a la temperature desiree. 12. Si l’appareil ne fonctionne pas, suivre les instructions intitulees “Pour fermer le gaz qui alimente l’appareil” et appeler un technicien ou le fournisseur de gaz. AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS A LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATERIELS, DES BLESSURES CORPORELLES OU MEME DES PERTES DE VIE. POUR VOTRE SECURITE, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE A. Cet appareil est muni d’une veilleuse qui doi...
Questo manuale è adatto anche per i modelli :Altri accessori per la casa - B-40REN (1.55 mb)
Altri accessori per la casa - B-40REP (1.55 mb)
Altri accessori per la casa - B-40RMP (1.55 mb)