Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Jacuzzi, Modello GQ99000

Produttore : Jacuzzi
File Size : 230.91 kb
File Nome : 4cfd8458-9d58-4a52-83e2-79ca43.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


The Lamp can be installed on most Jacuzzi baths or on any bath having sufficient flat space on the bath shell. The basic kit consists of an electrical control box and one Chromatherapy Lamp, with all necessary modular cables. The control box can support up to four lamps. An additional lamp kit is available and provides one lamp and one cable. The installation requires drilling a hole in the bath shell for the control panel and each lamp. The Installation and Operation Instructions will provide all the information required for planning the installation, completing the installation, and complete operation of the equipment. The control box must be installed meeting applicable local building and electrical codes on a stud beam or wall. CONTENTS Basic Lamp Kit . . . . . . . . . . . . . . . . . . . . . 1 Planning Installation . . . . . . . . . . . . . . . . . . 1 Control Panel . . . . . . . . . . . . . . . . . . . . 2 Chromatherapy Lamp . . . . . . . . . . . . . . . . 2 Mount the Control Box . . . . . . . . . . . . . . . . . 3 Drill the Holes . . . . . . . . . . . . . . . . . . . . . 3 Drill Hole for Control Panel . . . . . . . . . . . . . 3 Drill Hole for Lamp(s) . . . . . . . . . . . . . . . . 3 Install Panel and Lamp(s) . . . . . . . . . . . . . . . 4 Mount Control Panel . . . . . . . . . . . . . . . . 4 Mount Chromatherapy Lamp(s) . . . . . . . . . . . 4 Leak Test . . . . . . . . . . . . . . . . . . . . . . . . 5 Operate Chromatherapy Lighting . . . . . . . . . . . 5 Use Chromatherapy Lighting . . . . . . . . . . . . 5 Control Chromatherapy Lighting . . . . . . . . . . 5 Control Color Lighting . . . . . . . . . . . . . . 5 Control White Lighting . . . . . . . . . . . . . . 5 Basic lamp KitS GD56000 Complete kit One control box for wall mounting One control panel and one control cable (RJ-45 plug) One lamp and one lamp cable (RJ-11 plug) GQ88000 Accessory lamp kit One lamp and one lamp cable (RJ-11 plug) To add an additional lamp, up to four total, order the accessory lamp kit. It includes one lamp and one lamp cable. Each lamp is mounted in the same manner, and is connected to the control box as described. To order additional lamps, please contact your Jacuzzi dealer or agent. IMPORTANT: Read the instructions before beginning the installation. PLANNING INSTALLATION It is necessary to plan the location of the control box, control panel, and each lamp before drilling any holes. A possible configuration of the Chromatherapy equipment is shown in Figure 1. First, consider the location requirements for the control panel and lamp(s), see Figure 2. The control panel cannot be immersed in the bath water. Therefore it must be positioned at least one inch above the level of the overflow drain. On the other hand, the lamp(s) must be positioned a minimum of 4 inches below the normal water line. Control panel Lamp 1 Lamp 2 Figure 1. Possible configuation for Chromatherapy assembly Top rim of bath Hole for control panel 1 inch Overflow drain Normal water line 4 inches (minimum) Hole for lamp(s) Floor of bath Figure 2. Locate the Holes for Control Panel and Lens(es) Copyright © 2008 by Jacuzzi Whirlpool Bath Products GQ99000 • 07-08 Jacuzzi© Chromatherapy: Installation and Operation Page of 5 GQ99000 • 07-08 CAUTION: The panel and lamp(s) require modular cables from behind. Make sure the proposed location of the panel and lamp(s) will not cause cables to interfere with the bath plumbing The control panel and each lamp must be mounted on a minimum flat surface space of the bath shell, see Table 1, Mounting Surface Requirements. Table 1. Mounting Surface Requiements EQUIPMENT FLAT MOUNTING SURFACE ------------------------------------------------------------------------ Control panel 3 x 2 inches Lamp (each) 2-1/2 by 2-1/2 inches Next, consider the following cable lengths, starting with the control box. See Table 2, Cable Lengths. Table 2. Cable Lengths CABLE LENGTH -------------------------------------------------------- Control box cable 32 inches Control panel cable 72 inches (6 feet) Chromatheraphy lamp 84 inches (7 feet) The control box must be mounted on a stud beam or secure wall within 32 inches of the GFCI power outlet. The outlet must be a minimum of 4 inches above the floor. In addition it must be located no further than the length that the modular control cable or any lamp cable may extend. Once the location of the control box has been determined, you may determine the location of the control panel and the lamp(s), and prepare to drill a hole for each item. Control Panel Before marking the inside of the bath shell, place masking tape over the entre area of the proposed hole. The tape will help prevent chipping of the acrylic. Writing on the tape, use a pointed marker to indicate the outline of the hole for the control panel, see Figure 3. The control panel is 2-1/2 by 1-1/2 inches and requires a minimum of 3 by 2 inch flat mounting surface. Carefully mark the center of the hole. Also mark the 5/32 inch notch at the...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie