The pH reading should be between 7.2 and 7.8. If the level is too low, add a pH increaser (usually soda ash). If the level is too high, add a pH reducer (usually sodium bisulfate). Test the water again after five minutes. See the instructions with your pH test kit for additional information about testing and adjusting the pH. To remove the access cover, first remove the four access cover screws. Slide the access cover down and then pull the bottom of it away from the spa unit. Be careful not to damage the spa shell as you remove the cover. Access Cover Screws Screws Spa Shell If the spa will be stored for any period of time, place the power cord inside the spa unit before re-attaching the access cover. To reattach the access cover, insert the top of the cover under the edge of the spa shell. Slide the cover up until the bottom of the cover clears the trim along the bottom of the spa unit. Slide the cover into place and re-attach it with the two access cover screws. DRAINING THE RENEW 207 The RENEW 207 should be drained at least four times a year and refilled with clean water. You may need to drain the spa more often, depending on the user load. This must be done, because after repeated chemical treatment, the water becomes chemically saturated. Once this happens, additional chemical treatment of the water is no longer effective. The spa should also be drained if it will not be used for long periods of time. The spa must always be drained before major repairs are made. The RENEW 207 should always be covered when it is empty. Direct sunlight can cause extensive damage. The surface of the spa shell can reach temperatures as high as 150. F in a matter of minutes if exposed to the sun while it is empty. These high temperatures can cause significant damage, such as blistering of the shell surface and warping of the spa shell. Any damage caused by sun exposure is not covered under warranty. 14 To drain the RENEW 207, follow these steps: 1. Set the temperature control on the console to the lowest setting. 2. Unplug the power cord. 3. Remove the access cover from the spa. 4. Remove the drainage hose from the clip and attach a garden hose to the valve on the drainage hose. KnobValve Drain Hose 5. Open the valve by turning the knob counterclockwise. The water will begin to drain. 6. When the spa is empty, close the valve and remove the garden hose. Return the drainage hose to the clip and re-attach the access cover. 7. Refill the spa and treat the water with chemicals (see pages 8 and 14). WINTER USE AND CARE The RENEW 207 is designed for year-round use. If you decide to store the spa for the winter, store it in a warm, dry location. Follow the steps below to winterize the spa. 1. Drain the spa (see DRAINING THE RENEW 207 on page 14). 2. Remove all remaining water from the spa shell. Dry the spa shell with towels. 3. Set the air control on the console to the lowest setting. Use a wet/dry vacuum to pull any remaining water from the system. To do this, place the vacuum nozzle over each thera-jet, starting with the highest one and finishing with the lowest one. 4. Set the air control on the console to the highest setting and repeat step 3. 5. Clean the spa shell (see page 13). 6. Clean the filter (see page 13). 7. Re-attach the access cover. 8. Re-attach the spa cover. 15 TROUBLE-SHOOTING Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time. 1. SYMPTOM: THE SPA WILL NOT OPERATE a. Check the power cord. The power cord must be plugged into a grounded outlet (see PLUGGING IN THE RENEW 207 on page 10). b. Check the GFCI breaker to see if it is tripped or if it was not turned on. Reset the GFCI breaker. 2. SYMPTOM: THE CIRCUIT BREAKER OR GFCI BREAKER TRIPS WHILE THE SPA IS OPERATING a. Reset the circuit breaker. If the circuit breaker trips again, contact a qualified electrician for service. 3. SYMPTOM: THE PUMP HUMS a. The filter may be dirty or damaged. Remove the filter from the filter housing of the spa jet unit and clean or replace the filter. b. The pump may have a foreign object stuck in the impeller. Contact our customer service department or, if your spa is no longer under warranty, you may also contact a local spa and pool service provider. c. The pump may have a loose wire connection. Contact our customer service department or, if your spa is no longer under warranty, you may also contact a local spa and pool service provider. 4. SYMPTOM: THE PUMP HUMS BUT DOES NOT ROTATE a. The pump may be jammed. Contact our customer service department. If your spa is no longer under warranty, you may wish to contact a local spa and pool service provider. 5. SYMPTOM: THE PUMP IS NOISY WHILE OPERATING a. There may be debris in the pump. Contact our customer service department. If your spa is no longer under...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie