|
Istruzioni per l'uso Emerson, Modello CMF200A
Produttore : Emerson File Size : 1.3 mb File Nome : 5fbe926a-f70d-4654-aac4-d70914def90a.pdf
Lingua di insegnamento:
|
|
|
|
Vai a scaricare
Facilità d'uso
All rights reserved. ELITE and ProLink are registered trademarks, and MVD and MVD Direct Connect are trademarks of Micro Motion, Inc., Boulder, Colorado. Micro Motion is a registered trade name of Micro Motion, Inc., Boulder, Colorado. The Micro Motion and Emerson logos are trademarks and service marks of Emerson Electric Co. All other trademarks are property of their respective owners. Before You Begin Before You Begin This manual describes how to install a Micro Motion® ELITE® sensor. The following information is provided in this manual: Customer service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page1 Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 2 European installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page2 Installation options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page2 Installation steps Determining a Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page6 Orienting the Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page10 Mounting the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page11 Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16 Grounding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page20 Additional information Pressure Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page20 Purge Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 21 Rupture Disks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page22 ReturnPolicy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page23 Customer service For technical assistance, phone the Micro Motion Customer Service department: • In the U.S.A., phone 800-522-MASS (800-522-6277) (toll free) • In Canada and Latin America, phone +1 303-527-5200 (U.S.A.) •In Asia: -In Japan, phone 3 5769-6803 -In other locations, phone +65 6777-8211 (Singapore) •In Europe: -In the U.K., phone 0870 240 1978 (toll-free) -In other locations, phone +31 (0) 318 495 555 (The Netherlands) Customers outside the U.S.A. can also email Micro Motion customer service at International.MMISupport@EmersonProcess.com. Troubleshooting Refer to the transmitter manual for troubleshooting help. Installation Manual Before You Begin Specifications Full product specifications can be found in the product data sheet, which is available from the Micro Motion web site at Definitions The term MVD™ transmitter refers to the following transmitter models: • Models 1500, 1700, 2400S, 2500, and 2700 • Models 3500 and 3700 The term high-temperature ELITE sensor refers to the following model codes: • CMF200A, CMF300A, CMF400A, and CMFHC3A • CMF200B and CMF300B The term extreme high-temperature ELITE sensor refers to the following model codes: • CMF200C, CMF300C, CMF400C, and CMFHC3C • CMF200E and CMF300E European installations This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this manual. Refer to the EC declaration of conformity for directives that apply to this product. The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the internet at or through your local Micro Motion support center. Information affixed to equipment that complies with the Pressure Equipment Directive can be found on the internet at Installation options The ELITE sensor makes up one part of a Coriolis flowmeter. The other part is a transmitter. ELITE sensors are available with the following electronics interfaces: • An integral Model 2400S transmitter or enhanced core processor (see Figure 1). • An integral core processor for connecting to a 4-wire remotely mounted transmitter or to a user-supplied remote host (see Figure 2). • A 9-wire junction box for connecting to a remotely mounted transmitter or a remotely mounted core processor (see Figure 3). • High-temperature and extreme high-temperature models are equipped with a flexible conduit, on which can be mounted a Model 2400S transmitter, a Model 1700/2700 transmitter, a core processor, or a junction box (see Figure 4). Micro Motion® ELITE® Sensors Before You Begin Figure 1 ELITE sensor with Model 2400S transmitter or enhanced core processor Flow direction arrow Purge fittings or rupture disks (optional) Calibration tag Thru holes for alt...
Scrivi la tua opinione del dispositivo
|
|