Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Black & Decker, Modello Fire Storm FSSF100

Produttore : Black & Decker
File Size : 409.07 kb
File Nome : 7df0c7e6-0dad-455c-9bbd-77f7efd35b30.pdf

Lingua di insegnamento: enesfr

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


FSSF100 TTHANKHANK YOUYOU FORFOR CHOOSINGCHOOSING FFIRESTIRESTORMORM!! GGOO TTOO WWWWWW.F.FIRESTIRESTORMTORMTOOLSOOLS..COMCOM/P/PRODUCTRODUCTRREGISTRAEGISTRATIONTION TTOO REGISTERREGISTER YOURYOUR NEWNEW PRODUCTPRODUCT.. BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1-800-544-6986 BEFORE YOU CALL, HAVE THE CATALOG No. AND DATE CODE AVAILABLE. IN MOST CASES, A BLACK & DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE. IF YOU HAVE A SUGGESTION OR COMMENT, GIVE US A CALL. YOUR FEEDBACK IS VITAL TO BLACK & DECKER. SAVE THIS MANUAL FOR FUTURE REFERENCE. VEA EL ESPANOL EN LA CONTRAPORTADA. INSTRUCTIVO DE OPERACION, CENTROS DE SERVICIO Y POLIZA DE GARANTIA. ADVERTENCIA: LEASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO. Cat No. FSSF100 Form # 90503117 (MAR. ‘06) Copyright © 2006 Black & Decker Printed in China WARNING: To reduce the risk of injury, user must read and understand instruction manual. SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS • Do not operate the stud sensor in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. • Use the stud sensor only with the specifically designated batteries. Use of any other batteries may create a risk of fire. OPERATING INSTRUCTIONS CAUTION: Use caution when drilling, nailing or cutting into walls, floors and ceilings which may contain electrical wiring or pipes. These items may be detected by the Stud Finder in the same manner in which studs are detected. Because studs are normally spaced 16 inches or 24 inches apart and are 1-1/2 inches wide, beware of anything closer together or of a different width. Always turn off the power when working near electrical wires. INSTALLING THE BATTERY Remove the battery compartment cover (D) by pressing down in the center of the cover and pulling back. Insert two fresh AA batteries making sure to match (+) and (-) terminals correctly. Replace the battery compartment cover. CALIBRATION AND SCANNING 1.) Hold unit straight up and down and place flat against wall as shown in Figure 2. 2.) Press in and hold the stud sensor ON/OFF button (C). a.) The upper red LED (A) will light, b.) The unit will beep once while it is calibrating, c.) The bottom green LED (B) will light. 3.) Slide sensor slowly, (Figure 3,) horizontally across surface of wall without lifting or tilting. 4.) The upper red LED will light and a beeper will sound when an edge is detected , mark that spot (Figure 4). Repeat this cycle coming from the other direction and again mark the spot where the upper red LED lights and beeper sounds. Measure between the two marks made on the wall and the center will coincide with the center of the stud. TIPS FOR OPTIMUM USE • Test batteries before each use. Press and hold the on/off switch until the green LED lights. Then move your free hand toward the back of the unit. The red light should illuminate and then go out as you move your hand away from the unit. Replace the batteries if the red LED does not illuminate. • Hold stud sensor straight up and down. • Because studs are normally spaced 16 inches or 24 inches apart and are 1-1/2 inches wide, beware of anything closer together or of a different width. Doors and windows are constructed with studs and headers which are closer together. • Metal or wood studs can be detected through up to 3/4” drywall. • Avoid materials which have inconsistent density such as: • Carpeting and padding • Ceramic floor tile • Wallpaper containing metallic foils or fibers. Generally, surfaces covered with regular wallpaper or fabric will scan with no difference in function. • Walls that are freshly painted and are still damp. • Excessively thick plaster and lath. MAINTENANCE Use only mild soap and damp cloth to clean the tool. Never let any liquid get inside the tool; never immerse any part of the tool into a liquid. IMPORTANT: To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment (other than those listed in this manual) should be performed by authorized service centers or other qualified service personnel, always using identical replacement parts. WARNING: The use of any accessory not recommended for use with this tool could be hazardous. FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FEATURES A.) Red LED (Light Emitting Diode) B.) Green LED C.) On/Off Button D.) Battery Compartment Cover 1342BDCA T TTTTR RRRRO OOOOU UUUUB BBBBL LLLLE EEEES SSSSH HHHHO OOOOO OOOOT TTTTI IIIIN NNNNG GGGG Problem Possible Cause Solution • LEDs do not light. • Weak battery. • Nothing to detect in that area. • Check mode. May have been calibrated over a stud. • Replace with fresh batteries. • Start again moving farther to either side. • LED lights and sound stay on. • Wall thickness is over 3/4 inch thick. • Thickness must...

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie