Produttore : Adaptec
File Size : 692.76 kb
File Nome :
|
da questo dispositivo ha anche altre istruzioni :
Facilità d'uso
XMODEM transfer protocol. The message, “Ready to receive xmodem download.” appears. DuraStor 6200S/7200S Dual Controller Configuration Guide From the terminal menu, select Transfer, then Send File. Click Browse to navigate to the firmware file and click Open. Note: If you downloaded a newer version of the firmware from navigate to the directory where you saved the file. An example of the firmware file name is shown in the Filename field. Verify that the protocol is set to Xmodem and click Send. The upgrade takes about 3 minutes. Upgrading the Controller Firmware The controller automatically restarts to enable the new firmware. The activity status and firmware version is displayed in the terminal window on the second line after the restart. From the System Menu, select Shutdown/Restart to shutdown the system. 10 Remove the primary controller from the Controller 1 bay. Refer to the DuraStor Installation and User’s Guide. Note: On the 6220SS, 7220SS, and 6200SR, the RAID controllers are located in the 1U RAID appliance. To access these controllers, remove the front bezel. 11 Install the second controller in the Controller 1 bay. Refer to the DuraStor Installation and User’s Guide. This controller now becomes the new primary controller. 12 Verify the firmware of the new primary controller. See Verifying the Firmware Version on Your Controller on page 3. If both controllers have the same firmware, continue with Changing the Controller’s Operating Mode on page 8; otherwise, upgrade the firmware on the new primary controller following steps 1 through 8. Then, proceed to Changing the Controller’s Operating Mode on page 8. DuraStor 6200S/7200S Dual Controller Configuration Guide Changing the Controller’s Operating Mode To set up a dual-controller environment, change the mode of the primary controller to your preferred dual-controller configuration, reboot the controller, and then install the second controller. Note: If you need to upgrade the firmware on both controllers in your dual-controller system, upgrade the firmware before changing the configuration mode. You can set the following configuration modes: ¦ Active-Active Single Port ¦ Active-Passive Dual Port ¦ Active-Active Dual Port (7200S only) To set the operating mode: 1 Start a terminal session and connect to the controller as described in Verifying the Firmware Version on Your Controller on page 3 steps 1- 3. 2 Press Ctrl+R to refresh the terminal screen. 3 Press Enter until the System Menu in the Adaptec Disk Array Administrator System window is displayed. 4 Select Configuration Menu and press Enter. 5 Select the Option Configuration menu and press Enter. Changing the Controller’s Operating Mode Select Operating Mode and press Enter. Select the operating mode type and press Enter. 8 Exit out of the Adaptec Disk Array Administrator and shut down the controller. 9 Remove the front bezel from the DuraStor storage subsystem and remove the controller. Refer to the...