Log:
valutazioni - 1, GPA: 5 ( )

Istruzioni per l'uso Emerson, Modello 3051S

Produttore : Emerson
File Size : 2.73 mb
File Nome : 1949e218-e10a-4ca4-aaf0-7192b3b03dcf.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


All rights reserved. All marks property of owner. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. HART® .00825-0100-4801J¤ Quick Installation Guide 00825-0100-4801, Rev HA Rosemount 3051S February 2008 Rosemount Inc. 8200 Market Boulevard Chanhassen, MN USA 55317 T (US) (800) 999-9307 T (Intnl) (952) 906-8888 F (952) 949-7001 Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947/65 6777 0743 Emerson Process Management GmbH & Co. OHG Argelsrieder Feld 3 82234 Wessling Germany T 49 (8153) 9390, F49 (8153) 939172 Beijing Rosemount Far East Instrument Co., Limited No. 6 North Street, Hepingli, Dong Cheng District Beijing 100013, China T (86) (10) 6428 2233 F (86) (10) 6422 8586 IMPORTANT NOTICE This installation guide provides basic guidelines for Rosemount 3051S transmitters (reference manual document number 00809-0100-4801). It also provides the basic electronics guidelines for the 3051SFA (reference manual document number 00809-0100-4809), 3051SFC (reference manual document number 00809-0100-4810), and 3051SFP (reference manual document number 00809-0100-4686). It does not provide instructions for diagnostics, maintenance, service, or troubleshooting. This document is also available electronically on Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S WARNING Explosions could result in death or serious injury: Installation of this transmitter in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices. Please review the approvals section of the 3051S reference manual for any restrictions associated with a safe installation. • Before connecting a HART communicator in an explosive atmosphere, ensure the instruments in the loop are installed in accordance with intrinsically safe or non-incendive field wiring practices. • In an Explosion-Proof/Flame-Proof installation, do not remove the transmitter covers when power is applied to the unit. Process leaks may cause harm or result in death. • Install and tighten process connectors before applying pressure. Electrical shock can result in death or serious injury. • Avoid contact with the leads and terminals. High voltage that may be present on leads can cause electrical shock. Quick Installation Guide 00825-0100-4801, Rev HA Rosemount 3051S February 2008 4 STEP 1: MOUNT THE TRANSMITTER Liquid Flow Applications 1. Place taps to the side of the line. 2. Mount beside or below the taps. 3. Mount the transmitter so that the drain/vent valves are oriented upward. Gas Flow Applications 1. Place taps in the top or side of the line. 2. Mount beside or above the taps. Steam Flow Applications 1. Place taps to the side of the line. 2. Mount beside or below the taps. 3. Fill impulse lines with water. Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 5 STEP 1 CONTINUED... Panel Mount Pipe Mount Coplanar ™ Flange Traditional Flange In-line Housings PlantWeb ™ Junction Box Remote Mount Display Quick Installation Guide 00825-0100-4801, Rev HA Rosemount 3051S February 2008 STEP 2: CONSIDER HOUSING ROTATION To improve field access to wiring or to Figure 1. Transmitter Housing Set Screw better view the optional LCD display: 1. Loosen the housing rotation set screw. PlantWeb Junction Box 2. First rotate the housing clockwise to the desired location. If the desired location cannot be achieved due to thread limit, rotate the housing counter clockwise to the desired location (up to 360° from thread limit). 3. Retighten the housing rotation set screw. STEP 3: SET SWITCHES AND JUMPERS If alarm and security adjustment option is not installed, the transmitter will operate normally with the default alarm condition alarm high and the security off. Figure 2. Transmitter Switch and Jumper Configuration Housing Rotation Set Screw (3/32-inch) PlantWeb Junction Box AlarmSecurity Meter/ Adjustment Module Slide the security and alarm switches into the preferred position by using a small screwdriver. (A LCD display or an adjustment module must be in place to activate the switches.) Security Alarm Pull the jumpers out and rotate 90° into desired position to set the security and alarm. Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 7 STEP 4: CONNECT WIRING AND POWER UP Use the following steps to wire the transmitter: 1. Remove the housing cover labeled “Field Terminals.” 2. Connect the positive lead to the “+” terminal, and the negative lead to the “–” terminal. NOTE Do not connect the power across the test terminals. Power could damage the test diode in the test connection. Twisted pairs yield best results. For single compartment housing (Junction Box housing), shielded signal wiring should be used in high EMI/RFI environments. Use 24 AWG to 14 AWG wire and do not exceed 5,000 feet (1500 meters). 3. Plug...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie