NO SMOKING signs should be prominently displayed. Textiles and other materials that normally would not burn are easily ignited and burn with great intensity in oxygen enriched air. Failure to observe this warning can result in severe fire, property damage and cause physical injury or death. Part No 1118353 5 Platinum™ Series SPECIAL NOTES CAUTION “Caution: Federal law restricts this device to sale or rental by or on order of a physician, or any other practitioner licensed by the law of the State in which he/she practices to use or order the use of this device.” Invacare recommends an alternate source of supplemental oxygen in the event of a power outage, alarm condition or mechanical failure. Consult your physician or equipment provider for the type of reserve system required. This equipment is to be used as an oxygen supplement and isnot considered life supporting or life sustaining. Platinum™ Series 6 Part No 1118353 LABEL LOCATION Part No 1118353 7 Platinum™Series LABEL LOCATION HomeFill II Compati b l e I/O Operating Instructions (See Operator's Manual) Alarms (See Operator's Manual) WARNING - RISK OF FIRE NO SMOKING - Keep ALL sources of ignition out of the room in which this product is located and away from areas where oxygen is being delivered.Textiles, oils and other combustibles are easily ignited and burn with great intensity in oxygen enriched air. CAUTION - RISK OF ELECTRIC SHOCK Do not remove cover. Refer servicing to qualified service personnel. Flow rates below 0.5 L/min. will trigger Low Flow Alarm (rapid audible alarm). Set flowmeter at 3 L/min. or less when filling HomeFill II cylinder s . CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. P/N 1108820 HomeFill II Compatible withSensO2™ Operating Instructions (See Operator's Manual) Alarms (See Operator's Manual) WARNING - RISK OF FIRE NO SMOKING - Keep ALL sources of ignition out of the room in which this product is located and away from areas where oxygen is being delivered.Textiles, oils and other combustibles are easily ignited and burn with great intensity in oxygen enriched air. CAUTION - RISK OF ELECTRIC SHOCK Do not remove cover. Refer servicing to qualified service personnel. Flow rates below 0.5 L/min. will trigger Low Flow Alarm (rapid audible alarm). Set flowmeter at 3 L/min. or less when filling HomeFill II cylinders. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. cylinder s . Compati b le P/N 1108755 Serial Number Label is located on the resonator intake assembly Specification Label is located on the back near the bottom IRC5LX and IRC10LX IRC5LXO2 and IRC10LXO2 SECTION 1—GENERAL GUIDELINES SECTION 1—GENERAL GUIDELINES In order to ensure the safe installation, assembly and operation of the Platinum concentrator these instructionsMUST be followed. WARNING This section contains important information for the safeoperation and use of this product. To Reduce the Risk of Burns, Electrocution, Fire or Injury to Persons DANGER Risk of electric shock. DO NOT disassemble. Refer servicing to qualified service personnel. No user serviceable parts. Avoid using while bathing. If continuous usage is required by the physician’s prescription, the concentrator MUST be located in another room at least 7 ft from the bath. DO NOT come in contact with the concentrator while wet. DO NOT place or store product where it can drop into water or other liquid. DO NOT reach for product that has fallen into water. Unplug IMMEDIATELY. If the concentrator has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water, call qualified technician for examination and repair. A spontaneous and violent ignition may occur if oil, grease or greasy substances come in contact with oxygen under pressure. These substances MUST be kept away from the oxygen concentrator, tubing and connections, and all other oxygen equipment. DO NOT use any lubricants unless recommended by Invacare. Avoid creation of any spark near medical oxygen equipment. This includes sparks from static electricity created by any type of friction. Platinum™ Series 8 Part No 1118353 SECTION 1—GENERAL GUIDELINES Operating Information For optimum performance, Invacare recommends that each concentrator be on and running for a minimum of 30 minutes at a time. Shorter periods of operation may reduce maximum product life. Keep the oxygen tubing, cord, and unit out from under such items as blankets, bed coverings, chair cushions, clothing and away from heated or hot surfaces, including space heaters, stoves and similar electrical appliances. DO NOT move or relocate concentrator by pulling on the power cord. NEVER drop or insert any object or liquid into any opening. Invacare recommends that Crush.Proof oxygen tubing be used with this product and not exceed 15.2 m (50 ft) in length. There are no user serviceable parts. This does not include normal maintenance items. See mai...

Questo manuale è adatto anche per i modelli :
Altri dispositivi personali - IRC10LX (754.33 kb)
Altri dispositivi personali - IRC5LX (754.33 kb)
Altri dispositivi personali - IRC10LXO2 (754.33 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie