Log:
valutazioni - 2, GPA: 3 ( )

Istruzioni per l'uso Toshiba, Modello Mobile Projectors TDP-S25U

Produttore : Toshiba
File Size : 2.06 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


• When the lamp bursts, a slight amount of mercury gas enclosed in the lamp along with glass dust may be released from the openings for ventilation. ¦ Immediately replace the lamp when • When the replacement time approaches, a message will appear on the screen. • The risk of burst will increase if the lamp is continuously used without being replaced. •Frequently check the used hours and prepare spares when the replacement approaches. (Refer to “Status display”. p.33 ) ¦ When the lamp is broken • If glass components, including a lamp and a lens, should break, handle the broken pieces with care to avoid injury and contact your dealer for repair service. • In the event of lamp burst, unplug the product from the wall outlet, leave and completely ventilate the room. Then, thoroughly clean the area around the projector and discard any edible items placed in that area. • When the lamp bursts, consult a doctor if glass dust or mercury gas gets into your eyes or you breathe it. Lamp replacement A lamp is consumable supplies. If used for extended periods, images will appear dark, and the lamp could burn out. This is characteristic of a lamp, and is not malfunction. (The lifetime of the lamp depends on condition of use.) If this happens, replace it with a new one. WARNING • If the projector is mounted on the ceiling, it is recommended to use your Toshiba dealership when the lamp has to be exchanged. • When replacing, always use lamp “TLPLV5” (sold separately). CAUTION • If you have been using the projector, the lamp will be very hot, and may cause burn injuries. Wait for the lamp to cool (for longer than 1 hour) before replacing it. • If the lamp should break, please handle with care to avoid injury due to broken pieces and contact your dealer for repair service. 38 1 Unplug power 2 Wait until lamp is cooled. Wait for at least 1 hour. Lamp cover 3 Remove the lamp cover. Loosen the 2 screws, then pull up to the direction of the arrow with your fingers as shown to remove the lamp cover. Use care to avoid any damage to nails and/or tip of your finger(s). If you have any difficulty in removal, you can use a screwdriver or any other smaller tool for your convenience. 4 Pull out the lamp. Loosen the 2 screws holding the lamp in place, and pull up the handle to remove the lamp. 5 Mount the new lamp. Align the orientation, press down until the bottom is reached, and lock in place using the two lamp locking screws. 6 Replace the lamp cover. Align the cover, and press it in, then tighten the screws loosened in step 3 until the lamp cover is no longer loose. 7 Reset the lamp timer. 1 2 1 2 2 1 3 4 5 See the lamp’s manual for instructions on resetting the lamp timer. Notes and Precautions • Press the button twice to display (a rough guide) the time of lamp use, the Lamp time item, in the Status display menu. p.33 • It is recommended that the lamp be replaced after 3,000 hours of use. When Lamp time reaches 3,000 hours, the icon and a message will appear. This display disappears when you press button. • Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the lamp may fail to come on p.41 , and the lamp’s lifetime may be shortened. • Always replace the lamp with a new one. • The lamp is made out of glass. Do not touch the glass surface with your bare hands, bang it, or scratch it. (Dirt, jolts, scratches and the like could break the lamp.) 39 Maintenance Lamp Trouble indications Lamp Trouble indications Used Lamps The indicator lights you of internal abnormalities. This projector’s lamps contain trace amounts of environmentally harmful inorganic mercury. Be careful not to break and dispose of them local regulations. Lens and main unit WARNING • Request cleaning and maintenance of a ceiling-mounted projector dealership. Attempting to clean/replace the lamp at a high site yourself may cause you to drop down, thus resulting in injury. TEMP No powerLAMP FAN . Problem with projector • Unplug the power cord, and contact your dealer. (Off) TEMP Lamp went out during use, or won’t FAN . Lamp temperature is high so that it is difficult to turn on, the lifetime of (Red lit) the lamp has ended or the projector is malfunctioning. • Unplug the power cord and wait for a short while, then turn the power back on. (Red lit) • If a lamp burns out, replace it with a new one. . After approx. one minute of abnormal display, the projector returns to the standby state waiting for internal cool down. TEMP Power went out during use LAMP FAN . Internal overheating, or the outside temperature is too high. (Green lit) (Red lit or flashing) • Place the projector so that the air intake and exhaust are not blocked. • Unplug the power cord and wait for a short while, then turn the power back on. Or (Orange lit) . The icon will appear before the power goes out. . After approx. one minute of abnormal display, the projector returns to (Red lit) the standby state waiting for internal cool down. TEMP Power went out during useLAMP F...

Questo manuale è adatto anche per i modelli :
Proiettori - Mobile Projectors TDP-SC25U (2.06 mb)
Proiettori - TDP-S25U (2.06 mb)
Proiettori - TDP-SC25U (2.06 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie