Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Chamberlain, Modello OTIU

Produttore : Chamberlain
File Size : 358.54 kb
File Nome : 114A3530.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Keep antenna clear of obstruction. Plug in antenna. AC Adapter Antenna The Indoor Telephone Interface uses a 900 Mhz secure digital radio link that allows secure conversations and gate operator control. The Telephone Interface Unit (OTIU) is compatible with various Liftmaster Wireless Products. Step 1 Plug in the AC Adapter. The Power LED will light. Plug the included phone cord in the LINE port and connect it to the phone jack in the wall. Plug the cord from the phone in the PHONE port. Step 2 Step 3 Step 4 1 Program Accessories With Existing Network Step 1: On the phone connected to the OTIU, press “**07” after hearing the dial tone. Listen for double beep. Hang up and Learn LED will flash for 15 seconds. If an error tone is heard it means that memory will have to be cleared (see Troubleshooting). Step 2: Within 15 seconds enter Master PIN Number on GAPLM. Step 3: Press “05” and GAPLM will beep. The OTIU will ring the telephone and Caller ID will display “Unit Learned”. Step 1: Set Dipswitch #1 on the DAILM to the UP position to set the DAILM as a primary device. Step 2: On the phone connected to the OTIU, press “**07” after hearing the dial tone. Hang up and Learn LED will flash for 15 seconds. If an error tone is heard it means that memory will have to be cleared (see Troubleshooting). Step 3: Within 15 seconds, press and release the Learn button on the DAILM. Step 4: The OTIU will ring the telephone and Caller ID will display “Unit Learned”. Step 1: On the phone connected to the OTIU, press “**07” after hearing the dial tone. Hang up and Learn LED will flash for 15 seconds. If an error tone is heard it means that memory will have to be cleared (see Troubleshooting). Step 2: Within 15 seconds press the Learn button on ONE Repeater. The LED will light. Step 3: The OTIU will ring the telephone and Caller ID will display “Unit Learned”. NOTE: If the Repeaters have not been programmed to anything within an existing network, see Repeater manual for further instructions. NOTE: If programming into an existing network, ensure the OTIU is programmed to the Active unit. Repeaters Gate Access Panel (GAPLM) DAILM Program Accessories With Existing Network Step 1: On the phone connected to the OTIU, press “**07” after hearing the dial tone. Listen for double beep. Hang up and Learn LED will flash for 15 seconds. If an error tone is heard it means that memory will have to be cleared (see Troubleshooting). Step 2: Within 15 seconds enter Master PIN Number on GAPLM. Step 3: Press “05” and GAPLM will beep. The OTIU will ring the telephone and Caller ID will display “Unit Learned”. Step 1: Set Dipswitch #1 on the DAILM to the UP position to set the DAILM as a primary device. Step 2: On the phone connected to the OTIU, press “**07” after hearing the dial tone. Hang up and Learn LED will flash for 15 seconds. If an error tone is heard it means that memory will have to be cleared (see Troubleshooting). Step 3: Within 15 seconds, press and release the Learn button on the DAILM. Step 4: The OTIU will ring the telephone and Caller ID will display “Unit Learned”. Step 1: On the phone connected to the OTIU, press “**07” after hearing the dial tone. Hang up and Learn LED will flash for 15 seconds. If an error tone is heard it means that memory will have to be cleared (see Troubleshooting). Step 2: Within 15 seconds press the Learn button on ONE Repeater. The LED will light. Step 3: The OTIU will ring the telephone and Caller ID will display “Unit Learned”. NOTE: If the Repeaters have not been programmed to anything within an existing network, see Repeater manual for further instructions. NOTE: If programming into an existing network, ensure the OTIU is programmed to the Active unit. Repeaters Gate Access Panel (GAPLM) DAILM 2 Features & Operation Answering Calls (Regular Mode) When visitor presses the Call button on intercom, the telephone connected to the OTIU will ring distinctively up to four times. If an expandable OTIU system is used all phones within the system will ring. When phone is answered it will connect to the Intercom at gate or door. After connecting to the Intercom, the gate can be activated by dialing “*9”. To activate the primary gate operator dial “*9” on the phone connected to the OTIU. Learn LED Power LED Antenna Phone Line AC Adapter Caller ID When there is a visitor at the gate the OTIU will display “Gate Visitor” on a Caller ID telephone (or Caller ID box) that is directly connected to it. When there is a visitor at the door, the OTIU will display “Front Door” or “Back Door” depending on how you have your door Intercom set up (see Intercom manual). If someone is tampering with the gate, the OTIU will ring the phone and display “!Gate Tamper!”. Call Waiting If talking on the phone connected to OTIU, a distinctive beep will be heard indicating Call Waiting. Caller ID will alert that there is a visitor. To place call on hold and connect to the Intercom, press the FLASH button. If talking on phone other than th...

Questo manuale è adatto anche per i modelli :
Telefoni con filo - OTIU (358.54 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie